Comminuted radial head fractures treated with a modular metallic radial head arthroplasty. Study of outcomes.

Ruby Grewal1, Joy C MacDermid, Kenneth J Faber, Darren S Drosdowech, Graham J W King.   

Abstract

BACKGROUND: Comminuted fractures of the radial head are challenging to treat with open reduction and internal fixation. Radial head arthroplasty is an alternative treatment with results that compare favorably with those reported after open reduction and internal fixation of similar fractures. The purpose of this study was to evaluate the two-year outcomes and the rate of recovery of a closely followed cohort of patients in whom an unreconstructible radial head fracture had been treated with a modular metallic prosthesis.
METHODS: Twenty-six patients (seventeen female and nine male; mean age, fifty-four years) with an unreconstructible comminuted radial head fracture and associated elbow injuries were treated with a modular metallic radial head arthroplasty. Patients who had presented more than four weeks following the injury or had had the radial head arthroplasty as a second-stage or salvage procedure were excluded. Of the twenty-six patients, twenty-two had an associated elbow dislocation, and thirteen of them also had an associated fracture of the coronoid process. Patients were prospectively followed at three, six, twelve, and twenty-four months. Self-reported limb function, general health, range of motion, and isometric strength were assessed by an independent observer.
RESULTS: Following treatment of the injury, significant decreases in self-reported and measured impairments were noted over time, with the majority of the recovery occurring by six months and little further recovery noted between six and twenty-four months. There were slight-to-moderate deficits in the range of motion and strength compared with the values on the contralateral, unaffected side. Patient satisfaction was high at three months and remained high at two years. All elbow joints remained stable, no implant required revision, and there was no evidence of overstuffing of the joint. Mild osteoarthritis was seen in five (19%) of the twenty-six patients.
CONCLUSIONS: An arthroplasty with a modular metallic radial head is a safe and effective option for the treatment of unreconstructible radial head fractures associated with other elbow injuries. Recovery primarily occurs by six months, with minimal additional improvements over the next eighteen months.

Entities:  

Mesh:

Year:  2006        PMID: 17015596     DOI: 10.2106/JBJS.E.00962

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  55 in total

1.  Primary cemented bipolar radial head prostheses for acute elbow injuries with comminuted radial head fractures: mid-term results of 37 patients.

Authors:  R Laun; S Tanner; J-P Grassmann; J Schneppendahl; M Wild; M Hakimi; J Windolf; P Jungbluth
Journal:  Musculoskelet Surg       Date:  2018-12-04

2.  Comparison between radial head replacement and open reduction and internal fixation in clinical treatment of unstable, multi-fragmented radial head fractures.

Authors:  Xiao Chen; Si-cheng Wang; Lie-hu Cao; Guo-qing Yang; Ming Li; Jia-can Su
Journal:  Int Orthop       Date:  2010-08-02       Impact factor: 3.075

3.  Is a silastic radial head still a reasonable option?

Authors:  Yariv Maghen; Andrew J Leo; Jennifer W Hsu; Michael R Hausman
Journal:  Clin Orthop Relat Res       Date:  2011-04       Impact factor: 4.176

4.  [Prosthesis after comminuted radial head fractures : midterm results].

Authors:  A Moghaddam; A Lennert; S Studier-Fischer; A Wentzensen; G Zimmermann
Journal:  Unfallchirurg       Date:  2008-12       Impact factor: 1.000

5.  [Endoprosthetics of acute radial head fractures].

Authors:  K J Burkhart; K Wegmann; C Ries; L P Müller
Journal:  Unfallchirurg       Date:  2013-08       Impact factor: 1.000

Review 6.  Open reduction and internal-fixation versus radial head replacement in treatment of Mason type III radial head fractures.

Authors:  Ning Li; Shaoying Chen
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-11-20

7.  Prosthetic radial head stem pull-out as a mode of failure: a biomechanical study.

Authors:  Dave Shukla; James Fitzsimmons; Kai-Nan An; Shawn O'Driscoll
Journal:  Int Orthop       Date:  2013-09-17       Impact factor: 3.075

8.  Simple overlay device for determining radial head and neck height.

Authors:  Jun-Gyu Moon; Richard D Southgate; James S Fitzsimmons; Shawn W O'Driscoll
Journal:  Skeletal Radiol       Date:  2010-03-01       Impact factor: 2.199

9.  Anthropometric study of the proximal radius: does radial head implant fit in all cases?

Authors:  Soo Hwan Kang; Dong Yeop Kim; Hyunwoo Park; Hyun Seok Song
Journal:  Int Orthop       Date:  2015-05-10       Impact factor: 3.075

10.  Open reduction and internal fixation of radial head fractures: do outcomes differ between simple and complex injuries?

Authors:  Jeffrey M Pike; Ruby Grewal; George S Athwal; Kenneth J Faber; Graham J W King
Journal:  Clin Orthop Relat Res       Date:  2014-07       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.