Literature DB >> 17342570

Morphometric parameters of the radial head: an anatomical study.

T C Koslowsky1, I Germund, F Beyer, K Mader, C F Krieglstein, J Koebke.   

Abstract

INTRODUCTION: Exact anatomical description of the proximal radius is imperative for the development of radial head prostheses. The purpose of this study was to measure the anatomical parameters of the radial head.
METHODS: Optosil imprints of 18 pairs of proximal radii fixed with formalin were taken. All possessed their native cartilage joint surface free of any arthritic defects. After being cut into 3 mm slices, the diameter of each slice was measured in steps of 30 degrees of rotation with the margo interosseous acting as a reference point.
RESULTS: Maximum radial head diameter was seen from the 0 to the 9 mm slice at a rotation of 30 degrees to full supination perpendicular to the proximal radioulnar joint. The diameter increased from the radiocapitular joint surface to the 6 mm slice, and then it decreased (P < 0.001). At the level of 6 mm the maximum radial head diameter was 24.13 mm (range 21.2-27.3 mm). The minimum diameter was seen perpendicular to the maximum; it also increased from the radiocapitular joint surface to the 6 mm slice and then decreased. There was a significant difference between the minimum and maximum diameter of each slice at a P-level of P < 0.001. Left and right sides were not significantly different at a P-level of 0.01.
CONCLUSION: Our data show that the radial head is neither round nor conical. It has a complex shape with an increasing size from the radiocapitular joint surface to the middle of the proximal radioulnar joint surface. No statistically significant differences could be observed between right and left radii.

Entities:  

Mesh:

Year:  2007        PMID: 17342570     DOI: 10.1007/s00276-007-0197-1

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  26 in total

1.  The anatomic features of the radial head and their implication for prosthesis design.

Authors:  W Swieszkowski; K Skalski; S Pomianowski; K Kedzior
Journal:  Clin Biomech (Bristol, Avon)       Date:  2001-12       Impact factor: 2.063

2.  The noncircular shape of the radial head.

Authors:  Roger P van Riet; Francis Van Glabbeek; Patricia G Neale; Hilde Bortier; Kai Nan An; Shawn W O'Driscoll
Journal:  J Hand Surg Am       Date:  2003-11       Impact factor: 2.230

3.  A comparative study between proximal radial morphology and the floating radial head prosthesis.

Authors:  Nebojsa Popovic; Julien Djekic; Roger Lemaire; Philippe Gillet
Journal:  J Shoulder Elbow Surg       Date:  2005 Jul-Aug       Impact factor: 3.019

4.  A cadaver study on volume and surface area of the fingertip.

Authors:  M Murai; H K Lau; B P Pereira; R W Pho
Journal:  J Hand Surg Am       Date:  1997-09       Impact factor: 2.230

5.  The anatomy of the proximal radioulnar joint.

Authors:  A P Weiss; H Hastings
Journal:  J Shoulder Elbow Surg       Date:  2009-02-25       Impact factor: 3.019

6.  Open reduction and internal fixation of fractures of the radial head.

Authors:  David Ring; Jaime Quintero; Jesse B Jupiter
Journal:  J Bone Joint Surg Am       Date:  2002-10       Impact factor: 5.284

7.  Results of acute excision of the radial head in elbow radial head fracture-dislocations.

Authors:  J Sanchez-Sotelo; O Romanillos; E G Garay
Journal:  J Orthop Trauma       Date:  2000 Jun-Jul       Impact factor: 2.512

8.  Open reduction and internal fixation of comminuted fractures of the radial head using low-profile mini-plates.

Authors:  M Ikeda; Y Yamashina; M Kamimoto; Y Oka
Journal:  J Bone Joint Surg Br       Date:  2003-09

9.  Silicone rubber replacement of the severely fractured radial head.

Authors:  R M Carn; J Medige; D Curtain; A Koenig
Journal:  Clin Orthop Relat Res       Date:  1986-08       Impact factor: 4.176

10.  Fractures of the radial head and neck treated with radial head excision.

Authors:  Pär Herbertsson; Per Olof Josefsson; Ralph Hasserius; Jack Besjakov; Fredrik Nyqvist; Magnus K Karlsson
Journal:  J Bone Joint Surg Am       Date:  2004-09       Impact factor: 5.284

View more
  7 in total

1.  Intra-articular compressive stress of the elbow joint in extension: an experimental study using Fuji films.

Authors:  C Chantelot; G Wavreille; C Dos Remedios; B Landejerit; C Fontaine; H Hildebrand
Journal:  Surg Radiol Anat       Date:  2008-01-29       Impact factor: 1.246

2.  Do the radial head prosthesis components fit with the anatomical structures of the proximal radioulnar joint?

Authors:  Kilian Wegmann; Moritz K Hain; Christian Ries; Wolfram F Neiss; Lars P Müller; Klaus J Burkhart
Journal:  Surg Radiol Anat       Date:  2014-12-28       Impact factor: 1.246

3.  Beveled posteromedial corner of the radial head: a three-dimensional micro-computed tomography modeling study.

Authors:  Arnold Adikrishna; Young-Ho Shin; Rizki F Zulkarnain; Hanpyo Hong; Yucheng Sun; In-Ho Jeon
Journal:  J Anat       Date:  2017-08-15       Impact factor: 2.610

4.  Treatment of radial head and neck fractures: in favor of anatomical reconstruction.

Authors:  K J Burkhart; K Wegmann; J Dargel; C Ries; L P Mueller
Journal:  Eur J Trauma Emerg Surg       Date:  2012-09-13       Impact factor: 3.693

5.  Subchondral bone density of the radial head measured with subtraction densitometry.

Authors:  T C Koslowsky; K Mader; A Brandenburg; M Hellmich; J Koebke
Journal:  Surg Radiol Anat       Date:  2008-01-09       Impact factor: 1.246

6.  Morphometric parameters of the radial neck: an anatomical study.

Authors:  T C Koslowsky; F Beyer; I Germund; K Mader; M Jergas; J Koebke
Journal:  Surg Radiol Anat       Date:  2007-05-10       Impact factor: 1.354

7.  Validation of the contralateral side as reference for selecting radial head implant sizes.

Authors:  Paul W L Ten Berg; Johannes G G Dobbe; Gerhard van Wolfswinkel; Simon D Strackee; Geert J Streekstra
Journal:  Surg Radiol Anat       Date:  2016-01-21       Impact factor: 1.246

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.