Literature DB >> 12550809

The effect of metallic radial head arthroplasty on radiocapitellar joint contact area.

Victor S Liew1, Ian C Cooper, Louis M Ferreira, James A Johnson, Graham J W King.   

Abstract

OBJECTIVE: This study determined the effect of metallic radial head arthroplasty on radiocapitellar joint contact area.
DESIGN: The contact area of eight intact radiocapitellar joints was assessed during simulated compressive loading. Subsequently, the same experiments were repeated after reconstruction with three different radial head implant sizes.
BACKGROUND: There has been an increasing use of metal radial head implants relative to silicone implants. However, the contact characteristics with the metal reconstruction have not been determined.
METHODS: A 100 N compressive load was applied to the radiocapitellar joint at three different flexion angles for the native joint and three different sizes of a metal head implant. An impression material was employed to quantify joint contact area.
RESULTS: Following metallic radial head arthroplasty, the contact area decreased by approximately two-thirds relative to the native radiocapitellar joint (P<0.001). Smaller implant sizes resulted in slightly larger contact areas (P<0.05). In addition, contact area decreased as joint flexion angle increased (P<0.04).
CONCLUSIONS: Selection of radial head implant size is likely not a significant factor with regard to contact area mechanics of the radiocapitellar articulation. RELEVANCE: The effect of radial head implant size on the contact area produced with the native capitellum is not known. This study shows that the design or selection of a metallic radial head implant from the viewpoint of size is likely not an important factor with regard to minimizing joint contact stresses.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12550809     DOI: 10.1016/s0268-0033(02)00172-9

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  5 in total

1.  Is a silastic radial head still a reasonable option?

Authors:  Yariv Maghen; Andrew J Leo; Jennifer W Hsu; Michael R Hausman
Journal:  Clin Orthop Relat Res       Date:  2011-04       Impact factor: 4.176

2.  [Endoprosthetics of acute radial head fractures].

Authors:  K J Burkhart; K Wegmann; C Ries; L P Müller
Journal:  Unfallchirurg       Date:  2013-08       Impact factor: 1.000

3.  Do the radial head prosthesis components fit with the anatomical structures of the proximal radioulnar joint?

Authors:  Kilian Wegmann; Moritz K Hain; Christian Ries; Wolfram F Neiss; Lars P Müller; Klaus J Burkhart
Journal:  Surg Radiol Anat       Date:  2014-12-28       Impact factor: 1.246

4.  Radiocapitellar prosthetic arthroplasty in traumatic and post-traumatic complex lesions of the elbow.

Authors:  Prospero Bigazzi; Marco Biondi; Massimo Ceruso
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-08-20

Review 5.  [Destruction of the radial head : Endoprosthesis, autologous reconstruction or anconeus arthroplasty?]

Authors:  K J Burkhart; F Gohlke; R Nietschke; M M Schneider; B Hollinger
Journal:  Orthopade       Date:  2017-12       Impact factor: 1.087

  5 in total