Literature DB >> 25532172

A Small Surrogate for the Golden Angle in Time-Resolved Radial MRI Based on Generalized Fibonacci Sequences.

Stefan Wundrak, Jan Paul, Johannes Ulrici, Erich Hell, Volker Rasche.   

Abstract

In golden angle radial magnetic resonance imaging a constant azimuthal radial profile spacing of 111.246...(°) guarantees a nearly uniform azimuthal profile distribution in k-space for an arbitrary number of radial profiles. Even though this profile order is advantageous for various real-time imaging methods, in combination with balanced steady-state free precession (SSFP) sequences the large azimuthal angle increment may lead to strong image artifacts, due to the varying eddy currents introduced by the rapidly switching gradient scheme. Based on a generalized Fibonacci sequence, a new sequence of smaller irrational angles is introduced ( 49.750...(°), 32.039...(°), 27.198...(°), 23.628...(°), ... ). The subsequent profile orders guarantee the same sampling efficiency as the golden angle if at least a minimum number of radial profiles is used for reconstruction. The suggested angular increments are applied for dynamic imaging of the heart and the temporomandibular joint. It is shown that for balanced SSFP sequences, trajectories using the smaller golden angle surrogates strongly reduce the image artifacts, while the free retrospective choice of the reconstruction window width is maintained.

Mesh:

Year:  2014        PMID: 25532172     DOI: 10.1109/TMI.2014.2382572

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  27 in total

1.  Low rank alternating direction method of multipliers reconstruction for MR fingerprinting.

Authors:  Jakob Assländer; Martijn A Cloos; Florian Knoll; Daniel K Sodickson; Jürgen Hennig; Riccardo Lattanzi
Journal:  Magn Reson Med       Date:  2017-03-05       Impact factor: 4.668

2.  Low-dose CT perfusion with projection view sharing.

Authors:  Thomas Martin; John Hoffman; Jeff R Alger; Michael McNitt-Gray; Danny Jj Wang
Journal:  Med Phys       Date:  2017-11-17       Impact factor: 4.071

3.  Optimized quantification of spin relaxation times in the hybrid state.

Authors:  Jakob Assländer; Riccardo Lattanzi; Daniel K Sodickson; Martijn A Cloos
Journal:  Magn Reson Med       Date:  2019-06-12       Impact factor: 4.668

4.  GRASP-Pro: imProving GRASP DCE-MRI through self-calibrating subspace-modeling and contrast phase automation.

Authors:  Li Feng; Qiuting Wen; Chenchan Huang; Angela Tong; Fang Liu; Hersh Chandarana
Journal:  Magn Reson Med       Date:  2019-08-10       Impact factor: 4.668

5.  Validation of highly accelerated real-time cardiac cine MRI with radial k-space sampling and compressed sensing in patients at 1.5T and 3T.

Authors:  Hassan Haji-Valizadeh; Amir A Rahsepar; Jeremy D Collins; Elwin Bassett; Tamara Isakova; Tobias Block; Ganesh Adluru; Edward V R DiBella; Daniel C Lee; James C Carr; Daniel Kim
Journal:  Magn Reson Med       Date:  2017-09-17       Impact factor: 4.668

6.  Golden-ratio rotated stack-of-stars acquisition for improved volumetric MRI.

Authors:  Ziwu Zhou; Fei Han; Lirong Yan; Danny J J Wang; Peng Hu
Journal:  Magn Reson Med       Date:  2017-02-06       Impact factor: 4.668

7.  Anisotropic field-of-view support for golden angle radial imaging.

Authors:  Ziyue Wu; Fei Han; Peng Hu; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2015-08-24       Impact factor: 4.668

8.  Segmented golden ratio radial reordering with variable temporal resolution for dynamic cardiac MRI.

Authors:  Fei Han; Ziwu Zhou; Stanislas Rapacchi; Kim-Lien Nguyen; J Paul Finn; Peng Hu
Journal:  Magn Reson Med       Date:  2015-08-04       Impact factor: 4.668

9.  Accelerated, free-breathing, noncontrast, electrocardiograph-triggered, thoracic MR angiography with stack-of-stars k-space sampling and GRASP reconstruction.

Authors:  Hassan Haji-Valizadeh; Jeremy D Collins; Pascale J Aouad; Ali M Serhal; Marc D Lindley; Jianing Pang; Nivedita K Naresh; James C Carr; Daniel Kim
Journal:  Magn Reson Med       Date:  2018-09-05       Impact factor: 4.668

10.  A fast, noniterative approach for accelerated high-temporal resolution cine-CMR using dynamically interleaved streak removal in the power-spectral encoded domain with low-pass filtering (DISPEL) and modulo-prime spokes (MoPS).

Authors:  Keigo Kawaji; Mita B Patel; Charles G Cantrell; Akiko Tanaka; Marco Marino; Satoshi Tamura; Hui Wang; Yi Wang; Timothy J Carroll; Takeyoshi Ota; Amit R Patel
Journal:  Med Phys       Date:  2017-05-23       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.