Literature DB >> 25473125

A Study of Position-Sensitive Solid-State Photomultiplier Signal Properties.

Jeffrey P Schmall1, Junwei Du1, Martin S Judenhofer1, Purushottam Dokhale2, James Christian2, Mickel McClish2, Kanai S Shah2, Simon R Cherry1.   

Abstract

We present an analysis of the signal properties of a position-sensitive solid-state photomultiplier (PS-SSPM) that has an integrated resistive network for position sensing. Attractive features of PS-SSPMs are their large area and ability to resolve small scintillator crystals. However, the large area leads to a high detector capacitance, and in order to achieve high spatial resolution a large network resistor value is required. These inevitably create a low-pass filter that drastically slows what would be a fast micro-cell discharge pulse. Significant changes in the signal shape of the PS-SSPM cathode output as a function of position are observed, which result in a position-dependent time delay when using traditional time pick-off methods such as leading edge discrimination and constant fraction discrimination. The timing resolution and time delay, as a function of position, were characterized for two different PS-SSPM designs, a continuous 10 mm × 10 mm PS-SSPM and a tiled 2 × 2 array of 5 mm × 5 mm PS-SSPMs. After time delay correction, the block timing resolution, measured with a 6 × 6 array of 1.3 × 1.3 × 20 mm3 LSO crystals, was 8.6 ns and 8.5 ns, with the 10 mm PS-SSPM and 5 mm PS-SSPM respectively. The effect of crystal size on timing resolution was also studied, and contrary to expectation, a small improvement was measured when reducing the crystal size from 1.3 mm to 0.5 mm. Digital timing methods were studied and showed great promise for allowing accurate timing by implementation of a leading edge time pick-off. Position-dependent changes in signal shape on the anode side also are present, which complicates peak height data acquisition methods used for positioning. We studied the effect of trigger position on signal amplitude, flood histogram quality, and depth-of-interaction resolution in a dual-ended readout detector configuration. We conclude that detector timing and positioning can be significantly improved by implementation of digital timing methods and by accounting for changes in the shape of the signals from PS-SSPMs.

Entities:  

Keywords:  G-APDs; Positron emission tomography; depth-of-interaction; silicon photomultipliers; small animal imaging; solid-state photomultipliers

Year:  2014        PMID: 25473125      PMCID: PMC4249698          DOI: 10.1109/TNS.2014.2302635

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  15 in total

1.  High-resolution PET detector design: modelling components of intrinsic spatial resolution.

Authors:  Jennifer R Stickel; Simon R Cherry
Journal:  Phys Med Biol       Date:  2005-01-21       Impact factor: 3.609

2.  Evaluation of high performance data acquisition boards for simultaneous sampling of fast signals from PET detectors.

Authors:  Martin S Judenhofer; Bernd J Pichler; Simon R Cherry
Journal:  Phys Med Biol       Date:  2005-01-07       Impact factor: 3.609

3.  Convex optimization of coincidence time resolution for a high-resolution PET system.

Authors:  Paul D Reynolds; Peter D Olcott; Guillem Pratx; Frances W Y Lau; Craig S Levin
Journal:  IEEE Trans Med Imaging       Date:  2010-09-27       Impact factor: 10.048

4.  Experimental characterization and system simulations of depth of interaction PET detectors using 0.5 mm and 0.7 mm LSO arrays.

Authors:  Sara St James; Yongfeng Yang; Yibao Wu; Richard Farrell; Purushottam Dokhale; Kanai S Shah; Simon R Cherry
Journal:  Phys Med Biol       Date:  2009-06-30       Impact factor: 3.609

5.  Performance comparison of Si-PM-based block detectors with different pixel sizes for an ultrahigh-resolution small-animal PET system.

Authors:  Seiichi Yamamoto; Hiroshi Watabe; Jun Hatazawa
Journal:  Phys Med Biol       Date:  2011-09-21       Impact factor: 3.609

6.  A sub-millimeter resolution PET detector module using a multi-pixel photon counter array.

Authors:  Tae Yong Song; Heyu Wu; Sergey Komarov; Stefan B Siegel; Yuan-Chuan Tai
Journal:  Phys Med Biol       Date:  2010-04-14       Impact factor: 3.609

7.  Compact pulse width modulation circuitry for silicon photomultiplier readout.

Authors:  M F Bieniosek; P D Olcott; C S Levin
Journal:  Phys Med Biol       Date:  2013-07-08       Impact factor: 3.609

8.  Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET.

Authors:  Y Gu; J L Matteson; R T Skelton; A C Deal; E A Stephan; F Duttweiler; T M Gasaway; C S Levin
Journal:  Phys Med Biol       Date:  2011-02-18       Impact factor: 3.609

9.  Signal and noise properties of position-sensitive avalanche photodiodes.

Authors:  Yongfeng Yang; Yibao Wu; Richard Farrell; Purushottam A Dokhale; Kanai S Shah; Simon R Cherry
Journal:  Phys Med Biol       Date:  2011-09-06       Impact factor: 3.609

10.  A study of the timing properties of position-sensitive avalanche photodiodes.

Authors:  Yibao Wu; Thomas S C Ng; Yongfeng Yang; Kanai Shah; Richard Farrell; Simon R Cherry
Journal:  Phys Med Biol       Date:  2009-08-11       Impact factor: 3.609

View more
  2 in total

1.  Multiplexing Readout for Time-of-Flight (TOF) PET Detectors Using Striplines.

Authors:  Heejong Kim; Chien-Min Kao; Yuexuan Hua; Qingguo Xie; Chin-Tu Chen
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-01-13

2.  Characterization of Large-Area SiPM Array for PET Applications.

Authors:  Junwei Du; Yongfeng Yang; Xiaowei Bai; Martin S Judenhofer; Eric Berg; Kun Di; Steve Buckley; Carl Jackson; Simon R Cherry
Journal:  IEEE Trans Nucl Sci       Date:  2016-02-15       Impact factor: 1.679

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.