Evaluation of corneal deformation analyzed with a Scheimpflug based device.

Michele Lanza1, Michela Cennamo2, Stefania Iaccarino2, Vito Romano3, Mario Bifani3, Carlo Irregolare2, Alessandro Lanza3.   

Abstract

PURPOSE: To evaluate the correlation between corneal biomechanical and morphological data in healthy eyes.
METHODS: A complete clinical eye examination of naïve eyes was followed by tomographic (Pentacam, Oculus, Wetzlar, Germany) and biomechanical (Corvis ST, Oculus, Wetzlar, Germany) evaluation. Linear regression between central corneal thickness (CCT), corneal volume (CV) and anterior corneal curvature measured with Sim'K (SK), versus corneal deformation parameters measured with Corvis ST have been run using SPSS software version 18.0.
RESULTS: Seventy-six eyes of 76 healthy subjects (44 women and 32 men) with a mean age of 36.84 ± 10.74 years and a mean refractive error of -0.55 ± 1.68 D (measured as spherical equivalent) were evaluated. Corneal deformation parameters were weakly correlated with corneal morphological parameters and with spherical equivalent. Although the correlations between deformation amplitude versus SK and between SK versus Velocity of Applanation 2, were higher than the others (R(2) = 0.28 and 0.26 respectively), none of them was statistically significant (p>0.01).
CONCLUSIONS: According with these findings, Corvis ST seems to be able to provide an analysis of corneal deformation independent from corneal morphological characteristics. If these data will be confirmed in further studies, this device could be useful in the management and screening of eyes with corneal diseases.
Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biomechanical evaluation; Corneal biomechanics; Corneal pachimetry; Naive eyes; Tomographic evaluation

Mesh:

Year:  2014        PMID: 25467289     DOI: 10.1016/j.clae.2014.10.002

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  9 in total

1.  Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas.

Authors:  Gabor Nemeth; Eszter Szalai; Ziad Hassan; Agnes Lipecz; Zsuzsa Flasko; Laszlo Modis
Journal:  Int J Ophthalmol       Date:  2017-02-18       Impact factor: 1.779

2.  Comparison of corneal biomechanics in Sjögren's syndrome and non-Sjögren's syndrome dry eyes by Scheimpflug based device.

Authors:  Qin Long; Jing-Yi Wang; Dong Xu; Ying Li
Journal:  Int J Ophthalmol       Date:  2017-05-18       Impact factor: 1.779

3.  Analysis of corneal biomechanical properties 25 years after myopic photorefractive keratectomy.

Authors:  Sibel Özdoğan; Gökhan Gürelik; Kamil Bilgihan
Journal:  Int Ophthalmol       Date:  2022-08-02       Impact factor: 2.029

4.  A new method for detecting the outer corneal contour in images from an ultra-fast Scheimpflug camera.

Authors:  Magdalena Jędzierowska; Robert Koprowski; Sławomir Wilczyński; Katarzyna Krysik
Journal:  Biomed Eng Online       Date:  2019-12-03       Impact factor: 2.819

5.  Effects of diabetic keratopathy on corneal optical density, central corneal thickness, and corneal endothelial cell counts.

Authors:  Feng Gao; Tao Lin; Yingzhe Pan
Journal:  Exp Ther Med       Date:  2016-07-05       Impact factor: 2.447

6.  Estimation of the Corneal Young's Modulus In Vivo Based on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging.

Authors:  Po-Jen Shih; Chun-Ju Huang; Tzu-Han Huang; Hung-Chou Lin; Jia-Yush Yen; I-Jong Wang; Hui-Jyun Cao; Wen-Pin Shih; Chi-An Dai
Journal:  J Ophthalmol       Date:  2017-11-08       Impact factor: 1.909

Review 7.  Retinal and Corneal Changes Associated with Intraocular Silicone Oil Tamponade.

Authors:  Mariantonia Ferrara; Giulia Coco; Tania Sorrentino; Kirti M Jasani; George Moussa; Francesco Morescalchi; Felipe Dhawahir-Scala; Francesco Semeraro; David H W Steel; Vito Romano; Mario R Romano
Journal:  J Clin Med       Date:  2022-09-05       Impact factor: 4.964

8.  Corneal Disease & Transplantation.

Authors:  Giulia Coco; Vito Romano
Journal:  J Clin Med       Date:  2022-07-29       Impact factor: 4.964

9.  Corneal biomechanical properties in healthy children measured by corneal visualization scheimpflug technology.

Authors:  Miao He; Hui Ding; Hong He; Chi Zhang; Liangping Liu; Xingwu Zhong
Journal:  BMC Ophthalmol       Date:  2017-05-17       Impact factor: 2.209

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.