A new method for detecting the outer corneal contour in images from an ultra-fast Scheimpflug camera.

Magdalena Jędzierowska1, Robert Koprowski2, Sławomir Wilczyński3, Katarzyna Krysik4.   

Abstract

BACKGROUND: The Corvis® ST tonometer is an innovative device which, by combining a classic non-contact tonometer with an ultra-fast Scheimpflug camera, provides a number of parameters allowing for the assessment of corneal biomechanics. The acquired biomechanical parameters improve medical diagnosis of selected eye diseases. One of the key elements in biomechanical measurements is the correct corneal contour detection, which is the basis for further calculations. The presented study deals with the problem of outer corneal edge detection based on a series of images from the afore-mentioned device. Corneal contour detection is the first and extremely important stage in the acquisition and analysis of corneal dynamic parameters. RESULT: A total of 15,400 images from the Corvis® ST tonometer acquired from 110 patients undergoing routine ophthalmologic examinations were analysed. A method of outer corneal edge detection on the basis of a series of images from the Corvis® ST was proposed. The method was compared with known and commonly used edge detectors: Sobel, Roberts, and Canny operators, as well as others, known from the literature. The analysis was carried out in MATLAB® version 9.0.0.341360 (R2016a) with the Image Processing Toolbox (version 9.4) and the Neural Network Toolbox (version 9.0). The method presented in this paper provided the smallest values of the mean error (0.16%), stability (standard deviation 0.19%) and resistance to noise, characteristic for Corvis® ST tonometry tests, compared to the methods known from the literature. The errors were 5.78 ± 9.19%, 3.43 ± 6.21%, and 1.26 ± 3.11% for the Roberts, Sobel, and Canny methods, respectively.
CONCLUSIONS: The proposed new method for detecting the outer corneal contour increases the accuracy of intraocular pressure measurements. It can be used to analyse dynamic parameters of the cornea.

Entities:  

Keywords:  Canny; Corneal; Corneal contour; Corvis ST; Edge detection; Image processing; Roberts; Scheimpflug camera; Sobel; Tonometry

Mesh:

Year:  2019        PMID: 31796067      PMCID: PMC6888987          DOI: 10.1186/s12938-019-0735-1

Source DB:  PubMed          Journal:  Biomed Eng Online        ISSN: 1475-925X            Impact factor:   2.819


  47 in total

1.  Determining in vivo biomechanical properties of the cornea with an ocular response analyzer.

Authors:  David A Luce
Journal:  J Cataract Refract Surg       Date:  2005-01       Impact factor: 3.351

2.  Biomechanical properties of the cornea measured by the Ocular Response Analyzer and their association with intraocular pressure and the central corneal curvature.

Authors:  Sandra Franco; Madalena Lira
Journal:  Clin Exp Optom       Date:  2009-08-19       Impact factor: 2.742

3.  The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry.

Authors:  A Kotecha; E T White; J M Shewry; D F Garway-Heath
Journal:  Br J Ophthalmol       Date:  2005-12       Impact factor: 4.638

Review 4.  In vivo human corneal deformation analysis with a Scheimpflug camera, a critical review.

Authors:  Michele Lanza; Stefania Iaccarino; Mario Bifani
Journal:  J Biophotonics       Date:  2016-02-12       Impact factor: 3.207

5.  Evaluation of corneal deformation analyzed with a Scheimpflug based device.

Authors:  Michele Lanza; Michela Cennamo; Stefania Iaccarino; Vito Romano; Mario Bifani; Carlo Irregolare; Alessandro Lanza
Journal:  Cont Lens Anterior Eye       Date:  2014-11-21       Impact factor: 3.077

6.  Dynamic curvature topography for evaluating the anterior corneal surface change with Corvis ST.

Authors:  Chunhong Ji; Jinhua Yu; Tianjie Li; Lei Tian; Yifei Huang; Yuanyuan Wang; Yongping Zheng
Journal:  Biomed Eng Online       Date:  2015-06-04       Impact factor: 2.819

7.  Computed tomographic image analysis based on FEM performance comparison of segmentation on knee joint reconstruction.

Authors:  Seong-Wook Jang; Young-Jin Seo; Yon-Sik Yoo; Yoon Sang Kim
Journal:  ScientificWorldJournal       Date:  2014-11-27

8.  Intra-Ocular Pressure Measurement in a Patient with a Thin, Thick or Abnormal Cornea.

Authors:  Colin I Clement; Douglas G A Parker; Ivan Goldberg
Journal:  Open Ophthalmol J       Date:  2016-02-29

9.  Measurements of Corneal Thickness in Eyes with Pseudoexfoliation Syndrome: Comparative Study of Different Image Processing Protocols.

Authors:  Katarzyna Krysik; Dariusz Dobrowolski; Katarzyna Polanowska; Anita Lyssek-Boron; Edward A Wylegala
Journal:  J Healthc Eng       Date:  2017-09-07       Impact factor: 2.682

10.  Scheimpflug Camera and Swept-Source Optical Coherence Tomography in Pachymetry Evaluation of Diabetic Patients.

Authors:  Katarzyna Krysik; Dariusz Dobrowolski; Karolina Stanienda-Sokół; Edward A Wylegala; Anita Lyssek-Boron
Journal:  J Ophthalmol       Date:  2019-04-15       Impact factor: 1.909

View more
  1 in total

1.  Modification of Corneal Biomechanics and Intraocular Pressure Following Non-Penetrating Deep Sclerectomy.

Authors:  María Dolores Díaz-Barreda; Ignacio Sánchez-Marín; Ana Boned-Murillo; Itziar Pérez-Navarro; Juana Martínez; Elena Pardina-Claver; Diana Pérez; Francisco Javier Ascaso; Juan Ibáñez
Journal:  J Clin Med       Date:  2022-02-24       Impact factor: 4.241

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.