Intrasubject repeatability of corneal power, thickness, and wavefront aberrations with a new version of a dual rotating Scheimpflug-Placido system.

Alejandro Cerviño1, Alberto Dominguez-Vicent2, Teresa Ferrer-Blasco2, Santiago García-Lázaro2, Cesar Albarrán-Diego2.   

Abstract

PURPOSE: To determine the intrasubject repeatability of a recently introduced dual-camera rotating Scheimpflug-Placido imaging system (Galilei G4) in determining corneal thickness, power, and wavefront aberrations in young healthy subjects.
SETTING: University of Valencia, Valencia, Spain.
DESIGN: Prospective evaluation of diagnostic technology.
METHODS: The study comprised right eyes of 25 subjects aged 20 to 40 years with a spherical equivalent ranging from -4.25 to +1.00 diopters. The central corneal thickness, thinnest point value and location, anterior and posterior surface curvatures, total corneal power, and corneal wavefront aberrations were measured for distance vision using the dual Scheimpflug-Placido system. Three consecutive measurements were taken in each eye.
RESULTS: Twenty-five eyes were evaluated. Repeated-measures analysis of variance showed the only statistically significant difference between the 3 repeated measures to be in trefoil aberration. Intraclass correlation coefficients (ICCs) were higher than 0.950 for all the parameters except the thinnest point chord distance to geometric corneal center (0.528) and chord angle (0.742), corneal astigmatism (0.811) and its vector components J0 (0.891) and J45 (0.724), and all wavefront aberrations.
CONCLUSIONS: The new dual Scheimpflug-Placido system had high intraobserver repeatability for corneal power and thickness and moderate repeatability for corneal astigmatism and corneal wavefront aberrations in healthy corneas with low astigmatism. This iteration of the device performed better in young healthy corneas than preceding versions. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 25465211     DOI: 10.1016/j.jcrs.2014.04.037

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  9 in total

1.  Meibomian glands visibility assessment through a new quantitative method.

Authors:  José Vicente García-Marqués; Santiago García-Lázaro; Noelia Martínez-Albert; Alejandro Cerviño
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-01-06       Impact factor: 3.117

2.  Repeatability of Non-invasive Keratograph Break-Up Time measurements obtained using Oculus Keratograph 5M.

Authors:  José Vicente García-Marqués; Noelia Martínez-Albert; Cristian Talens-Estarelles; Santiago García-Lázaro; Alejandro Cerviño
Journal:  Int Ophthalmol       Date:  2021-03-16       Impact factor: 2.031

3.  Validation of corneal topographic and aberrometric measurements obtained by color light-emitting diode reflection topography in healthy eyes.

Authors:  David P Piñero; Ainhoa Molina-Martín; Vicent J Camps; Dolores de Fez; María Teresa Caballero
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-09-03       Impact factor: 3.117

4.  Intrasession repeatability of ocular anatomical measurements obtained with a multidiagnostic device in healthy eyes.

Authors:  David P Piñero; Inmaculada Cabezos; Alberto López-Navarro; Dolores de Fez; María T Caballero; Vicente J Camps
Journal:  BMC Ophthalmol       Date:  2017-10-18       Impact factor: 2.209

5.  Corneal Topographic and Aberrometric Measurements Obtained with a Multidiagnostic Device in Healthy Eyes: Intrasession Repeatability.

Authors:  David P Piñero; Alberto López-Navarro; Inmaculada Cabezos; Dolores de Fez; María T Caballero; Vicent J Camps
Journal:  J Ophthalmol       Date:  2017-01-04       Impact factor: 1.909

6.  Intrasession repeatability of refractive and ocular aberrometric measurements obtained using a multidiagnostic device in healthy eyes.

Authors:  David P Piñero; Alberto López-Navarro; Inmaculada Cabezos; Dolores de Fez; María T Caballero; Vicent J Camps
Journal:  Clin Optom (Auckl)       Date:  2017-05-04

7.  Comparison of higher order wavefront aberrations with four aberrometers.

Authors:  William H Cook; James McKelvie; Henry B Wallace; Stuti L Misra
Journal:  Indian J Ophthalmol       Date:  2019-07       Impact factor: 1.848

8.  Comparison of central corneal thickness measurements using different imaging devices and ultrasound pachymetry.

Authors:  Ertugrul Can; Hilal Eser-Ozturk; Mustafa Duran; Tugba Cetinkaya; Nursen Arıturk
Journal:  Indian J Ophthalmol       Date:  2019-10       Impact factor: 1.848

9.  Repeatability and reproducibility of corneal higher-order aberrations measurements after small incision lenticule extraction using the Scheimpflug-Placido topographer.

Authors:  Rui Ning; Rongrong Gao; David P Piñero; Jun Zhang; Qingyi Gao; Yili Jin; Yiran Wang; Chenxiao Wang; Jinhai Huang
Journal:  Eye Vis (Lond)       Date:  2022-01-04
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.