Literature DB >> 25426312

Noncontact depth-resolved micro-scale optical coherence elastography of the cornea.

Shang Wang1, Kirill V Larin1.   

Abstract

High-resolution elastographic assessment of the cornea can greatly assist clinical diagnosis and treatment of various ocular diseases. Here, we report on the first noncontact depth-resolved micro-scale optical coherence elastography of the cornea achieved using shear wave imaging optical coherence tomography (SWI-OCT) combined with the spectral analysis of the corneal Lamb wave propagation. This imaging method relies on a focused air-puff device to load the cornea with highly-localized low-pressure short-duration air stream and applies phase-resolved OCT detection to capture the low-amplitude deformation with nano-scale sensitivity. The SWI-OCT system is used here to image the corneal Lamb wave propagation with the frame rate the same as the OCT A-line acquisition speed. Based on the spectral analysis of the corneal temporal deformation profiles, the phase velocity of the Lamb wave is obtained at different depths for the major frequency components, which shows the depthwise distribution of the corneal stiffness related to its structural features. Our pilot experiments on ex vivo rabbit eyes demonstrate the feasibility of this method in depth-resolved micro-scale elastography of the cornea. The assessment of the Lamb wave dispersion is also presented, suggesting the potential for the quantitative measurement of corneal viscoelasticity.

Entities:  

Keywords:  (120.5050) Phase measurement; (170.4460) Ophthalmic optics and devices; (170.4500) Optical coherence tomography

Year:  2014        PMID: 25426312      PMCID: PMC4242019          DOI: 10.1364/BOE.5.003807

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  64 in total

1.  Assessment of viscous and elastic properties of sub-wavelength layered soft tissues using shear wave spectroscopy: theoretical framework and in vitro experimental validation.

Authors:  Thu-Mai Nguyen; Mathieu Couade; Jeremy Bercoff; Mickael Tanter
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-11       Impact factor: 2.725

2.  Assessment of corneal dynamics with high-speed swept source optical coherence tomography combined with an air puff system.

Authors:  David Alonso-Caneiro; Karol Karnowski; Bartlomiej J Kaluzny; Andrzej Kowalczyk; Maciej Wojtkowski
Journal:  Opt Express       Date:  2011-07-18       Impact factor: 3.894

3.  Needle optical coherence elastography for the measurement of microscale mechanical contrast deep within human breast tissues.

Authors:  Kelsey M Kennedy; Robert A McLaughlin; Brendan F Kennedy; Alan Tien; Bruce Latham; Christobel M Saunders; David D Sampson
Journal:  J Biomed Opt       Date:  2013-12       Impact factor: 3.170

4.  Confocal Brillouin microscopy for three-dimensional mechanical imaging.

Authors:  Giuliano Scarcelli; Seok Hyun Yun
Journal:  Nat Photonics       Date:  2007-12-09       Impact factor: 38.771

5.  DYNAMIC OPTICAL COHERENCE ELASTOGRAPHY: A REVIEW.

Authors:  Xing Liang; Vasilica Crecea; Stephen A Boppart
Journal:  J Innov Opt Health Sci       Date:  2010-10

6.  Anterior and posterior corneal stroma elasticity assessed using nanoindentation.

Authors:  Janice M Dias; Noël M Ziebarth
Journal:  Exp Eye Res       Date:  2013-06-22       Impact factor: 3.467

Review 7.  Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach.

Authors:  M J Doughty; M L Zaman
Journal:  Surv Ophthalmol       Date:  2000 Mar-Apr       Impact factor: 6.048

8.  Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes.

Authors:  Sunil Shah; Mohammed Laiquzzaman; Rajan Bhojwani; Sanjay Mantry; Ian Cunliffe
Journal:  Invest Ophthalmol Vis Sci       Date:  2007-07       Impact factor: 4.799

9.  In vivo three-dimensional optical coherence elastography.

Authors:  Brendan F Kennedy; Xing Liang; Steven G Adie; Derek K Gerstmann; Bryden C Quirk; Stephen A Boppart; David D Sampson
Journal:  Opt Express       Date:  2011-03-28       Impact factor: 3.894

10.  Distribution of Young's modulus in porcine corneas after riboflavin/UVA-induced collagen cross-linking as measured by atomic force microscopy.

Authors:  Jan Seifert; Christian M Hammer; Johannes Rheinlaender; Saadettin Sel; Michael Scholz; Friedrich Paulsen; Tilman E Schäffer
Journal:  PLoS One       Date:  2014-01-31       Impact factor: 3.240

View more
  54 in total

1.  Phase-sensitive optical coherence elastography at 1.5 million A-Lines per second.

Authors:  Manmohan Singh; Chen Wu; Chih-Hao Liu; Jiasong Li; Alexander Schill; Achuth Nair; Kirill V Larin
Journal:  Opt Lett       Date:  2015-06-01       Impact factor: 3.776

2.  Assessing the biomechanical properties of the porcine crystalline lens as a function of intraocular pressure with optical coherence elastography.

Authors:  Chen Wu; Salavat R Aglyamov; Zhaolong Han; Manmohan Singh; Chih-Hao Liu; Kirill V Larin
Journal:  Biomed Opt Express       Date:  2018-11-26       Impact factor: 3.732

3.  Assessing the effects of riboflavin/UV-A crosslinking on porcine corneal mechanical anisotropy with optical coherence elastography.

Authors:  Manmohan Singh; Jiasong Li; Zhaolong Han; Raksha Raghunathan; Achuth Nair; Chen Wu; Chih-Hao Liu; Salavat Aglyamov; Michael D Twa; Kirill V Larin
Journal:  Biomed Opt Express       Date:  2016-12-19       Impact factor: 3.732

4.  Ultra-fast line-field low coherence holographic elastography using spatial phase shifting.

Authors:  Chih-Hao Liu; Alexander Schill; Raksha Raghunathan; Chen Wu; Manmohan Singh; Zhaolong Han; Achuth Nair; Kirill V Larin
Journal:  Biomed Opt Express       Date:  2017-01-23       Impact factor: 3.732

Review 5.  Optical coherence elastography - OCT at work in tissue biomechanics [Invited].

Authors:  Kirill V Larin; David D Sampson
Journal:  Biomed Opt Express       Date:  2017-01-27       Impact factor: 3.732

6.  Applanation optical coherence elastography: noncontact measurement of intraocular pressure, corneal biomechanical properties, and corneal geometry with a single instrument.

Authors:  Manmohan Singh; Zhaolong Han; Achuth Nair; Alexander Schill; Michael D Twa; Kirill V Larin
Journal:  J Biomed Opt       Date:  2017-02-01       Impact factor: 3.170

7.  Optical coherence elastography for evaluating customized riboflavin/UV-A corneal collagen crosslinking.

Authors:  Manmohan Singh; Jiasong Li; Srilatha Vantipalli; Zhaolong Han; Kirill V Larin; Michael D Twa
Journal:  J Biomed Opt       Date:  2017-09-01       Impact factor: 3.170

8.  Wide-field optical coherence micro-elastography for intraoperative assessment of human breast cancer margins.

Authors:  Wes M Allen; Lixin Chin; Philip Wijesinghe; Rodney W Kirk; Bruce Latham; David D Sampson; Christobel M Saunders; Brendan F Kennedy
Journal:  Biomed Opt Express       Date:  2016-09-19       Impact factor: 3.732

9.  In-vivo 3D corneal elasticity using air-coupled ultrasound optical coherence elastography.

Authors:  Zi Jin; Reza Khazaeinezhad; Jiang Zhu; Junxiao Yu; Yueqiao Qu; Youmin He; Yan Li; Tomas E Gomez Alvarez-Arenas; Fan Lu; Zhongping Chen
Journal:  Biomed Opt Express       Date:  2019-11-14       Impact factor: 3.732

10.  In Vivo Noninvasive Measurement of Young's Modulus of Elasticity in Human Eyes: A Feasibility Study.

Authors:  Arthur J Sit; Shuai-Chun Lin; Arash Kazemi; Jay W McLaren; Christopher M Pruet; Xiaoming Zhang
Journal:  J Glaucoma       Date:  2017-11       Impact factor: 2.503

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.