Literature DB >> 26030564

Phase-sensitive optical coherence elastography at 1.5 million A-Lines per second.

Manmohan Singh, Chen Wu, Chih-Hao Liu, Jiasong Li, Alexander Schill, Achuth Nair, Kirill V Larin.   

Abstract

Shear-wave imaging optical coherence elastography (SWI-OCE) is an emerging method for 3D quantitative assessment of tissue local mechanical properties based on imaging and analysis of elastic wave propagation. Current methods for SWI-OCE involve multiple temporal optical coherence tomography scans (M-mode) at different spatial locations across tissue surface (B- and C-modes). This requires an excitation for each measurement position leading to clinically unacceptable long acquisition times up to tens of minutes. In this Letter, we demonstrate, for the first time, noncontact true kilohertz frame-rate OCE by combining a Fourier domain mode-locked swept source laser with an A-scan rate of ∼1.5  MHz and a focused air-pulse as an elastic wave excitation source. The propagation of the elastic wave in the sample was imaged at a frame rate of ∼7.3  kHz. Therefore, to quantify the elastic wave propagation velocity in a single direction, only a single excitation was needed. This method was validated by quantifying the elasticity of tissue-mimicking agar phantoms as well as of a porcine cornea ex vivo at different intraocular pressures. The results demonstrate that this method can reduce the acquisition time of an elastogram to milliseconds.

Entities:  

Mesh:

Year:  2015        PMID: 26030564      PMCID: PMC5451255          DOI: 10.1364/OL.40.002588

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  31 in total

1.  Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound.

Authors:  Ik-Kyung Jang; Brett E Bouma; Dong-Heon Kang; Seung-Jung Park; Seong-Wook Park; Ki-Bae Seung; Kyu-Bo Choi; Milen Shishkov; Kelly Schlendorf; Eugene Pomerantsev; Stuart L Houser; H Thomas Aretz; Guillermo J Tearney
Journal:  J Am Coll Cardiol       Date:  2002-02-20       Impact factor: 24.094

2.  Thyroid gland tumor diagnosis at US elastography.

Authors:  Andrej Lyshchik; Tatsuya Higashi; Ryo Asato; Shinzo Tanaka; Juichi Ito; Jerome J Mai; Claire Pellot-Barakat; Michael F Insana; Aaron B Brill; Tsuneo Saga; Masahiro Hiraoka; Kaori Togashi
Journal:  Radiology       Date:  2005-08-18       Impact factor: 11.105

3.  Elastography: a quantitative method for imaging the elasticity of biological tissues.

Authors:  J Ophir; I Céspedes; H Ponnekanti; Y Yazdi; X Li
Journal:  Ultrason Imaging       Date:  1991-04       Impact factor: 1.578

4.  Shear modulus imaging by direct visualization of propagating shear waves with phase-sensitive optical coherence tomography.

Authors:  Shaozhen Song; Zhihong Huang; Thu-Mai Nguyen; Emily Y Wong; Bastien Arnal; Matthew O'Donnell; Ruikang K Wang
Journal:  J Biomed Opt       Date:  2013-12       Impact factor: 3.170

5.  Optical coherence tomography.

Authors:  D Huang; E A Swanson; C P Lin; J S Schuman; W G Stinson; W Chang; M R Hee; T Flotte; K Gregory; C A Puliafito
Journal:  Science       Date:  1991-11-22       Impact factor: 47.728

6.  In vivo evidence of porcine cornea anisotropy using supersonic shear wave imaging.

Authors:  Thu-Mai Nguyen; Jean-Francois Aubry; Mathias Fink; Jeremy Bercoff; Mickael Tanter
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-10-28       Impact factor: 4.799

7.  Shear wave imaging optical coherence tomography (SWI-OCT) for ocular tissue biomechanics.

Authors:  Shang Wang; Kirill V Larin
Journal:  Opt Lett       Date:  2014-01-01       Impact factor: 3.776

8.  Measurement of corneal elasticity with an acoustic radiation force elasticity microscope.

Authors:  Eric Mikula; Kyle Hollman; Dongyul Chai; James V Jester; Tibor Juhasz
Journal:  Ultrasound Med Biol       Date:  2014-04-13       Impact factor: 2.998

9.  Biomechanical properties of human and porcine corneas.

Authors:  Ahmed Elsheikh; Daad Alhasso; Paolo Rama
Journal:  Exp Eye Res       Date:  2008-03-04       Impact factor: 3.467

10.  Stress-strain measurements of human and porcine corneas after riboflavin-ultraviolet-A-induced cross-linking.

Authors:  Gregor Wollensak; Eberhard Spoerl; Theo Seiler
Journal:  J Cataract Refract Surg       Date:  2003-09       Impact factor: 3.351

View more
  43 in total

1.  Acoustic radiation force optical coherence elastography for evaluating mechanical properties of soft condensed matters and its biological applications.

Authors:  Hsiao-Chuan Liu; Piotr Kijanka; Matthew W Urban
Journal:  J Biophotonics       Date:  2020-01-02       Impact factor: 3.207

2.  Clinical feasibility of optical coherence micro-elastography for imaging tumor margins in breast-conserving surgery.

Authors:  Wes M Allen; Ken Y Foo; Renate Zilkens; Kelsey M Kennedy; Qi Fang; Lixin Chin; Benjamin F Dessauvagie; Bruce Latham; Christobel M Saunders; Brendan F Kennedy
Journal:  Biomed Opt Express       Date:  2018-11-19       Impact factor: 3.732

3.  Assessing the effects of riboflavin/UV-A crosslinking on porcine corneal mechanical anisotropy with optical coherence elastography.

Authors:  Manmohan Singh; Jiasong Li; Zhaolong Han; Raksha Raghunathan; Achuth Nair; Chen Wu; Chih-Hao Liu; Salavat Aglyamov; Michael D Twa; Kirill V Larin
Journal:  Biomed Opt Express       Date:  2016-12-19       Impact factor: 3.732

4.  Ultra-fast line-field low coherence holographic elastography using spatial phase shifting.

Authors:  Chih-Hao Liu; Alexander Schill; Raksha Raghunathan; Chen Wu; Manmohan Singh; Zhaolong Han; Achuth Nair; Kirill V Larin
Journal:  Biomed Opt Express       Date:  2017-01-23       Impact factor: 3.732

Review 5.  Optical coherence elastography - OCT at work in tissue biomechanics [Invited].

Authors:  Kirill V Larin; David D Sampson
Journal:  Biomed Opt Express       Date:  2017-01-27       Impact factor: 3.732

Review 6.  High-speed OCT light sources and systems [Invited].

Authors:  Thomas Klein; Robert Huber
Journal:  Biomed Opt Express       Date:  2017-01-13       Impact factor: 3.732

7.  Applanation optical coherence elastography: noncontact measurement of intraocular pressure, corneal biomechanical properties, and corneal geometry with a single instrument.

Authors:  Manmohan Singh; Zhaolong Han; Achuth Nair; Alexander Schill; Michael D Twa; Kirill V Larin
Journal:  J Biomed Opt       Date:  2017-02-01       Impact factor: 3.170

8.  Single-shot two-dimensional spectroscopic magnetomotive optical coherence elastography with graphics processing unit acceleration.

Authors:  Pin-Chieh Huang; Rishyashring R Iyer; Yuan-Zhi Liu; Stephen A Boppart
Journal:  Opt Lett       Date:  2020-08-01       Impact factor: 3.776

9.  Biomechanical assessment of myocardial infarction using optical coherence elastography.

Authors:  Shang Wang; Manmohan Singh; Thuy Tien Tran; John Leach; Salavat R Aglyamov; Irina V Larina; James F Martin; Kirill V Larin
Journal:  Biomed Opt Express       Date:  2018-01-23       Impact factor: 3.732

10.  Wide-field quantitative micro-elastography of human breast tissue.

Authors:  Wes M Allen; Kelsey M Kennedy; Qi Fang; Lixin Chin; Andrea Curatolo; Lucinda Watts; Renate Zilkens; Synn Lynn Chin; Benjamin F Dessauvagie; Bruce Latham; Christobel M Saunders; Brendan F Kennedy
Journal:  Biomed Opt Express       Date:  2018-02-09       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.