Literature DB >> 21934782

Assessment of corneal dynamics with high-speed swept source optical coherence tomography combined with an air puff system.

David Alonso-Caneiro1, Karol Karnowski, Bartlomiej J Kaluzny, Andrzej Kowalczyk, Maciej Wojtkowski.   

Abstract

We present a novel method and instrument for in vivo imaging and measurement of the human corneal dynamics during an air puff. The instrument is based on high-speed swept source optical coherence tomography (ssOCT) combined with a custom adapted air puff chamber from a non-contact tonometer, which uses an air stream to deform the cornea in a non-invasive manner. During the short period of time that the deformation takes place, the ssOCT acquires multiple A-scans in time (M-scan) at the center of the air puff, allowing observation of the dynamics of the anterior and posterior corneal surfaces as well as the anterior lens surface. The dynamics of the measurement are driven by the biomechanical properties of the human eye as well as its intraocular pressure. Thus, the analysis of the M-scan may provide useful information about the biomechanical behavior of the anterior segment during the applanation caused by the air puff. An initial set of controlled clinical experiments are shown to comprehend the performance of the instrument and its potential applicability to further understand the eye biomechanics and intraocular pressure measurements. Limitations and possibilities of the new apparatus are discussed.

Entities:  

Mesh:

Year:  2011        PMID: 21934782     DOI: 10.1364/OE.19.014188

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  29 in total

1.  Development of an integrated optical coherence tomography-gas nozzle system for surgical laser ablation applications: preliminary findings of in situ spinal cord deformation due to gas flow effects.

Authors:  Ronnie Wong; Jamil Jivraj; Barry Vuong; Joel Ramjist; Nicole A Dinn; Cuiru Sun; Yize Huang; James A Smith; Victor X D Yang
Journal:  Biomed Opt Express       Date:  2014-12-05       Impact factor: 3.732

Review 2.  Optical coherence elastography - OCT at work in tissue biomechanics [Invited].

Authors:  Kirill V Larin; David D Sampson
Journal:  Biomed Opt Express       Date:  2017-01-27       Impact factor: 3.732

3.  Optical coherence elastography for evaluating customized riboflavin/UV-A corneal collagen crosslinking.

Authors:  Manmohan Singh; Jiasong Li; Srilatha Vantipalli; Zhaolong Han; Kirill V Larin; Michael D Twa
Journal:  J Biomed Opt       Date:  2017-09-01       Impact factor: 3.170

4.  A focused air-pulse system for optical-coherence-tomography-based measurements of tissue elasticity.

Authors:  Shang Wang; K V Larin; Jiasong Li; S Vantipalli; R K Manapuram; S Aglyamov; S Emelianov; M D Twa
Journal:  Laser Phys Lett       Date:  2013-05-20       Impact factor: 2.016

5.  In vivo estimation of elastic wave parameters using phase-stabilized swept source optical coherence elastography.

Authors:  Ravi Kiran Manapuram; Salavat R Aglyamov; Floredes M Monediado; Maleeha Mashiatulla; Jiasong Li; Stanislav Y Emelianov; Kirill V Larin
Journal:  J Biomed Opt       Date:  2012-10       Impact factor: 3.170

6.  Spatial characterization of corneal biomechanical properties with optical coherence elastography after UV cross-linking.

Authors:  Michael D Twa; Jiasong Li; Srilatha Vantipalli; Manmohan Singh; Salavat Aglyamov; Stanislav Emelianov; Kirill V Larin
Journal:  Biomed Opt Express       Date:  2014-04-04       Impact factor: 3.732

7.  Multi-meridian corneal imaging of air-puff induced deformation for improved detection of biomechanical abnormalities.

Authors:  Andrea Curatolo; Judith S Birkenfeld; Eduardo Martinez-Enriquez; James A Germann; Geethika Muralidharan; Jesús Palací; Daniel Pascual; Ashkan Eliasy; Ahmed Abass; Jędrzej Solarski; Karol Karnowski; Maciej Wojtkowski; Ahmed Elsheikh; Susana Marcos
Journal:  Biomed Opt Express       Date:  2020-10-14       Impact factor: 3.732

8.  Noncontact depth-resolved micro-scale optical coherence elastography of the cornea.

Authors:  Shang Wang; Kirill V Larin
Journal:  Biomed Opt Express       Date:  2014-10-06       Impact factor: 3.732

9.  Noncontact Elastic Wave Imaging Optical Coherence Elastography for Evaluating Changes in Corneal Elasticity Due to Crosslinking.

Authors:  Manmohan Singh; Jiasong Li; Srilatha Vantipalli; Shang Wang; Zhaolong Han; Achuth Nair; Salavat R Aglyamov; Michael D Twa; Kirill V Larin
Journal:  IEEE J Sel Top Quantum Electron       Date:  2015-12-17       Impact factor: 4.544

Review 10.  Application of Elastography for the Noninvasive Assessment of Biomechanics in Engineered Biomaterials and Tissues.

Authors:  Woong Kim; Virginia L Ferguson; Mark Borden; Corey P Neu
Journal:  Ann Biomed Eng       Date:  2016-01-20       Impact factor: 3.934