Literature DB >> 24399498

Optimized three-dimensional fast-spin-echo MRI.

John P Mugler1.   

Abstract

Spin-echo-based acquisitions are the workhorse of clinical MRI because they provide a variety of useful image contrasts and are resistant to image artifacts from radio-frequency or static field inhomogeneity. Three-dimensional (3D) acquisitions provide datasets that can be retrospectively reformatted for viewing in freely selectable orientations, and are thus advantageous for evaluating the complex anatomy associated with many clinical applications of MRI. Historically, however, 3D spin-echo-based acquisitions have not played a significant role in clinical MRI due to unacceptably long acquisition times or image artifacts associated with details of the acquisition method. Recently, optimized forms of 3D fast/turbo spin-echo imaging have become available from several MR-equipment manufacturers (for example, CUBE [GE], SPACE [Siemens], and VISTA [Philips]). Through specific design strategies and optimization, including short non-spatially selective radio-frequency pulses to significantly shorten the echo spacing and variable flip angles for the refocusing radio-frequency pulses to suppress blurring or considerably lengthen the useable duration of the spin-echo train, these techniques permit single-slab 3D imaging of sizeable volumes in clinically acceptable acquisition times. These optimized fast/turbo spin-echo pulse sequences provide a robust and flexible approach for 3D spin-echo-based imaging with a broad range of clinical applications.
Copyright © 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  3D FSE; 3D TSE; RARE; fast spin echo; turbo spin echo; variable flip angles

Mesh:

Substances:

Year:  2014        PMID: 24399498     DOI: 10.1002/jmri.24542

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  102 in total

Review 1.  MR Imaging of the Musculoskeletal System Using Ultrahigh Field (7T) MR Imaging.

Authors:  Hamza Alizai; Gregory Chang; Ravinder R Regatte
Journal:  PET Clin       Date:  2018-10

2.  Cerebral Venous Thrombosis: MR Black-Blood Thrombus Imaging with Enhanced Blood Signal Suppression.

Authors:  G Wang; X Yang; J Duan; N Zhang; M M Maya; Y Xie; X Bi; X Ji; D Li; Q Yang; Z Fan
Journal:  AJNR Am J Neuroradiol       Date:  2019-09-26       Impact factor: 3.825

3.  Contrast enhancement of intracranial lesions at 1.5 T: comparison among 2D spin echo, black-blood (BB) Cube, and BB Cube-FLAIR sequences.

Authors:  SungWoon Im; Ryuichiro Ashikaga; Yukinobu Yagyu; Tetsuya Wakayama; Mitsuharu Miyoshi; Tomoko Hyodo; Izumi Imaoka; Seishi Kumano; Kazunari Ishii; Takamichi Murakami
Journal:  Eur Radiol       Date:  2015-05-01       Impact factor: 5.315

4.  MS lesions are better detected with 3D T1 gradient-echo than with 2D T1 spin-echo gadolinium-enhanced imaging at 3T.

Authors:  A Crombé; M Saranathan; A Ruet; M Durieux; E de Roquefeuil; J C Ouallet; B Brochet; V Dousset; T Tourdias
Journal:  AJNR Am J Neuroradiol       Date:  2014-11-06       Impact factor: 3.825

5.  Analysis of phase error effects in multishot diffusion-prepared turbo spin echo imaging.

Authors:  Anh T Van; Barbara Cervantes; Hendrik Kooijman; Dimitrios C Karampinos
Journal:  Quant Imaging Med Surg       Date:  2017-04

6.  3T MRI Whole-Brain Microscopy Discrimination of Subcortical Anatomy, Part 1: Brain Stem.

Authors:  M J Hoch; M T Bruno; A Faustin; N Cruz; L Crandall; T Wisniewski; O Devinsky; T M Shepherd
Journal:  AJNR Am J Neuroradiol       Date:  2019-01-31       Impact factor: 3.825

7.  Isotropic 3D black blood MRI of abdominal aortic aneurysm wall and intraluminal thrombus.

Authors:  Chengcheng Zhu; Henrik Haraldsson; Farshid Faraji; Christopher Owens; Warren Gasper; Sinyeob Ahn; Jing Liu; Gerhard Laub; Michael D Hope; David Saloner
Journal:  Magn Reson Imaging       Date:  2015-10-22       Impact factor: 2.546

8.  Optimization of magnetization-prepared rapid gradient echo (MP-RAGE) sequence for neonatal brain MRI.

Authors:  Lili He; Jinghua Wang; Zhong-Lin Lu; Beth M Kline-Fath; Nehal A Parikh
Journal:  Pediatr Radiol       Date:  2018-05-02

9.  Automated patient-specific optimization of three-dimensional double-inversion recovery magnetic resonance imaging.

Authors:  Refaat E Gabr; Xiaojun Sun; Amol S Pednekar; Ponnada A Narayana
Journal:  Magn Reson Med       Date:  2015-03-11       Impact factor: 4.668

10.  Increased Speed and Image Quality for Pelvic Single-Shot Fast Spin-Echo Imaging with Variable Refocusing Flip Angles and Full-Fourier Acquisition.

Authors:  Andreas M Loening; Daniel V Litwiller; Manojkumar Saranathan; Shreyas S Vasanawala
Journal:  Radiology       Date:  2016-08-26       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.