Optimization of magnetization-prepared 3-dimensional fluid attenuated inversion recovery imaging for lesion detection at 7 T.

Manojkumar Saranathan1, Thomas Tourdias, Adam B Kerr, Jeff D Bernstein, Geoffrey A Kerchner, May H Han, Brian K Rutt.   

Abstract

PURPOSE: The aim of this study was to optimize the 3-dimensional (3D) fluid attenuated inversion recovery (FLAIR) pulse sequence for isotropic high-spatial-resolution imaging of white matter (WM) and cortical lesions at 7 T.
MATERIALS AND METHODS: We added a magnetization-prepared (MP) FLAIR module to a Cube 3D fast spin echo sequence and optimized the refocusing flip angle train using extended phase graph simulations, taking into account image contrast, specific absorption rate (SAR), and signal-to-noise ratio (SNR) as well as T1/T2 values of the different species of interest (WM, grey matter, lesions) at 7 T. We also effected improved preparation homogeneity at 7 T by redesigning the refocusing pulse used in the MP segments. Two sets of refocusing flip angle trains-(a) an SNR-optimal and (b) a contrast-optimal set-were derived and used to scan 7 patients with Alzheimer disease/cognitive impairment and 7 patients with multiple sclerosis. Conventional constant refocusing flip MP-FLAIR images were also acquired for comparison. Lesion SNR, contrast, and lesion count were compared between the 2 optimized and the standard FLAIR sequences.
RESULTS: Whole brain coverage with 0.8 mm isotropic spatial resolution in ∼5-minute scan times was achieved using the optimized 3D FLAIR sequences at clinically acceptable SAR levels. The SNR efficiency of the SNR-optimal sequence was significantly better than that of conventional constant refocusing flip MP-FLAIR sequence, whereas the scan time was reduced more than 2-fold (∼5 vs >10 minutes). The contrast efficiency of the contrast-optimal sequence was comparable with that of the constant refocusing flip sequence. Lesion load ascertained by lesion counting was not significantly different among the sequences.
CONCLUSION: Magnetization-prepared FLAIR-Cube with refocusing flip angle trains optimized for SNR and contrast can be used to characterize WM and cortical lesions at 7 T with 0.8 mm isotropic resolution in short scan times and without SAR penalty.

Entities:  

Mesh:

Year:  2014        PMID: 24566291      PMCID: PMC4852716          DOI: 10.1097/RLI.0000000000000041

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  31 in total

1.  Optimized single-slab three-dimensional spin-echo MR imaging of the brain.

Authors:  J P Mugler; S Bao; R V Mulkern; C R Guttmann; R L Robertson; F A Jolesz; J R Brookeman
Journal:  Radiology       Date:  2000-09       Impact factor: 11.105

2.  High-resolution magnetization-prepared 3D-FLAIR imaging at 7.0 Tesla.

Authors:  Fredy Visser; Jaco J M Zwanenburg; Johannes M Hoogduin; Peter R Luijten
Journal:  Magn Reson Med       Date:  2010-07       Impact factor: 4.668

3.  Brain MR imaging at ultra-low radiofrequency power.

Authors:  Subhendra N Sarkar; David C Alsop; Ananth J Madhuranthakam; Reed F Busse; Philip M Robson; Neil M Rofsky; David B Hackney
Journal:  Radiology       Date:  2011-02-25       Impact factor: 11.105

4.  kT -points: short three-dimensional tailored RF pulses for flip-angle homogenization over an extended volume.

Authors:  M A Cloos; N Boulant; M Luong; G Ferrand; E Giacomini; D Le Bihan; A Amadon
Journal:  Magn Reson Med       Date:  2011-05-16       Impact factor: 4.668

5.  Diagnosis of acetabular labral tears: comparison of three-dimensional intermediate-weighted fast spin-echo MR arthrography with two-dimensional MR arthrography at 3.0 T.

Authors:  So Young Park; Ji Seon Park; Wook Jin; Kee Hyung Rhyu; Kyung Nam Ryu
Journal:  Acta Radiol       Date:  2012-10-23       Impact factor: 1.990

6.  Initial clinical experience in MR imaging of the brain with a fast fluid-attenuated inversion-recovery pulse sequence.

Authors:  J N Rydberg; C A Hammond; R C Grimm; B J Erickson; C R Jack; J Huston; S J Riederer
Journal:  Radiology       Date:  1994-10       Impact factor: 11.105

Review 7.  Cerebral small vessel disease: from pathogenesis and clinical characteristics to therapeutic challenges.

Authors:  Leonardo Pantoni
Journal:  Lancet Neurol       Date:  2010-07       Impact factor: 44.182

8.  Cerebral microbleeds on MR imaging: comparison between 1.5 and 7T.

Authors:  M M A Conijn; M I Geerlings; G-J Biessels; T Takahara; T D Witkamp; J J M Zwanenburg; P R Luijten; J Hendrikse
Journal:  AJNR Am J Neuroradiol       Date:  2011-05-05       Impact factor: 3.825

9.  Diagnostic criteria for multiple sclerosis: 2010 revisions to the McDonald criteria.

Authors:  Chris H Polman; Stephen C Reingold; Brenda Banwell; Michel Clanet; Jeffrey A Cohen; Massimo Filippi; Kazuo Fujihara; Eva Havrdova; Michael Hutchinson; Ludwig Kappos; Fred D Lublin; Xavier Montalban; Paul O'Connor; Magnhild Sandberg-Wollheim; Alan J Thompson; Emmanuelle Waubant; Brian Weinshenker; Jerry S Wolinsky
Journal:  Ann Neurol       Date:  2011-02       Impact factor: 10.422

10.  Lesion detection at seven Tesla in multiple sclerosis using magnetisation prepared 3D-FLAIR and 3D-DIR.

Authors:  Wolter L de Graaf; Jaco J M Zwanenburg; Fredy Visser; Mike P Wattjes; Petra J W Pouwels; Jeroen J G Geurts; Chris H Polman; Frederik Barkhof; Peter R Luijten; Jonas A Castelijns
Journal:  Eur Radiol       Date:  2011-08-27       Impact factor: 5.315

View more
  13 in total

1.  MS lesions are better detected with 3D T1 gradient-echo than with 2D T1 spin-echo gadolinium-enhanced imaging at 3T.

Authors:  A Crombé; M Saranathan; A Ruet; M Durieux; E de Roquefeuil; J C Ouallet; B Brochet; V Dousset; T Tourdias
Journal:  AJNR Am J Neuroradiol       Date:  2014-11-06       Impact factor: 3.825

2.  MRI quality control for the Italian Neuroimaging Network Initiative: moving towards big data in multiple sclerosis.

Authors:  Loredana Storelli; Maria A Rocca; Patrizia Pantano; Elisabetta Pagani; Nicola De Stefano; Gioacchino Tedeschi; Paola Zaratin; Massimo Filippi
Journal:  J Neurol       Date:  2019-08-17       Impact factor: 4.849

3.  White-matter-nulled MPRAGE at 7T reveals thalamic lesions and atrophy of specific thalamic nuclei in multiple sclerosis.

Authors:  Vincent Planche; Jason H Su; Sandy Mournet; Manojkumar Saranathan; Vincent Dousset; May Han; Brian K Rutt; Thomas Tourdias
Journal:  Mult Scler       Date:  2019-02-07       Impact factor: 6.312

4.  7T MPFLAIR versus MP2RAGE for Quantifying Lesion Volume in Multiple Sclerosis.

Authors:  Margaret Spini; Seongjin Choi; Daniel M Harrison
Journal:  J Neuroimaging       Date:  2020-06-22       Impact factor: 2.486

Review 5.  Ultra-High-Field MR Neuroimaging.

Authors:  P Balchandani; T P Naidich
Journal:  AJNR Am J Neuroradiol       Date:  2014-12-18       Impact factor: 3.825

6.  Ultra-High-Field Targeted Imaging of Focal Cortical Dysplasia: The Intracortical Black Line Sign in Type IIb.

Authors:  E Bartolini; M Cosottini; M Costagli; C Barba; L Tassi; R Spreafico; R Garbelli; L Biagi; A Buccoliero; F Giordano; R Guerrini
Journal:  AJNR Am J Neuroradiol       Date:  2019-11-14       Impact factor: 3.825

Review 7.  Diagnosis of multiple sclerosis through the lens of ultra-high-field MRI.

Authors:  Pascal Sati
Journal:  J Magn Reson       Date:  2018-04-26       Impact factor: 2.229

8.  Automated Detection and Segmentation of Multiple Sclerosis Lesions Using Ultra-High-Field MP2RAGE.

Authors:  Mário João Fartaria; Pascal Sati; Alexandra Todea; Ernst-Wilhelm Radue; Reza Rahmanzadeh; Kieran OʼBrien; Daniel S Reich; Meritxell Bach Cuadra; Tobias Kober; Cristina Granziera
Journal:  Invest Radiol       Date:  2019-06       Impact factor: 6.016

9.  In Vivo 7T MR Quantitative Susceptibility Mapping Reveals Opposite Susceptibility Contrast between Cortical and White Matter Lesions in Multiple Sclerosis.

Authors:  W Bian; E Tranvinh; T Tourdias; M Han; T Liu; Y Wang; B Rutt; M M Zeineh
Journal:  AJNR Am J Neuroradiol       Date:  2016-06-09       Impact factor: 3.825

10.  7T MRI subthalamic nucleus atlas for use with 3T MRI.

Authors:  Mikhail Milchenko; Scott A Norris; Kathleen Poston; Meghan C Campbell; Mwiza Ushe; Joel S Perlmutter; Abraham Z Snyder
Journal:  J Med Imaging (Bellingham)       Date:  2018-01-08