Literature DB >> 25369288

Energy response calibration of photon-counting detectors using x-ray fluorescence: a feasibility study.

H-M Cho1, H Ding, B P Ziemer, S Molloi.   

Abstract

Accurate energy calibration is critical for the application of energy-resolved photon-counting detectors in spectral imaging. The aim of this study is to investigate the feasibility of energy response calibration and characterization of a photon-counting detector using x-ray fluorescence. A comprehensive Monte Carlo simulation study was performed using Geant4 Application for Tomographic Emission (GATE) to investigate the optimal technique for x-ray fluorescence calibration. Simulations were conducted using a 100 kVp tungsten-anode spectra with 2.7 mm Al filter for a single pixel cadmium telluride (CdTe) detector with 3 × 3 mm(2) in detection area. The angular dependence of x-ray fluorescence and scatter background was investigated by varying the detection angle from 20° to 170° with respect to the beam direction. The effects of the detector material, shape, and size on the recorded x-ray fluorescence were investigated. The fluorescent material size effect was considered with and without the container for the fluorescent material. In order to provide validation for the simulation result, the angular dependence of x-ray fluorescence from five fluorescent materials was experimentally measured using a spectrometer. Finally, eleven of the fluorescent materials were used for energy calibration of a CZT-based photon-counting detector. The optimal detection angle was determined to be approximately at 120° with respect to the beam direction, which showed the highest fluorescence to scatter ratio (FSR) with a weak dependence on the fluorescent material size. The feasibility of x-ray fluorescence for energy calibration of photon-counting detectors in the diagnostic x-ray energy range was verified by successfully calibrating the energy response of a CZT-based photon-counting detector. The results of this study can be used as a guideline to implement the x-ray fluorescence calibration method for photon-counting detectors in a typical imaging laboratory.

Entities:  

Mesh:

Year:  2014        PMID: 25369288      PMCID: PMC4241961          DOI: 10.1088/0031-9155/59/23/7211

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  18 in total

Review 1.  Medical applications of synchrotron radiation.

Authors:  P Suortti; W Thomlinson
Journal:  Phys Med Biol       Date:  2003-07-07       Impact factor: 3.609

2.  Synchrotron radiation in radiology: radiology techniques based on synchrotron sources.

Authors:  Reto Meuli; Yeukuang Hwu; Jung Ho Je; Giorgio Margaritondo
Journal:  Eur Radiol       Date:  2004-07-31       Impact factor: 5.315

3.  K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors.

Authors:  E Roessl; R Proksa
Journal:  Phys Med Biol       Date:  2007-07-17       Impact factor: 3.609

4.  Computed tomography with energy-resolved detection: a feasibility study.

Authors:  Polad M Shikhaliev
Journal:  Phys Med Biol       Date:  2008-02-19       Impact factor: 3.609

5.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography.

Authors:  J P Schlomka; E Roessl; R Dorscheid; S Dill; G Martens; T Istel; C Bäumer; C Herrmann; R Steadman; G Zeitler; A Livne; R Proksa
Journal:  Phys Med Biol       Date:  2008-07-08       Impact factor: 3.609

Review 6.  Vision 20/20: Single photon counting x-ray detectors in medical imaging.

Authors:  Katsuyuki Taguchi; Jan S Iwanczyk
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

7.  SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes.

Authors:  G Poludniowski; G Landry; F DeBlois; P M Evans; F Verhaegen
Journal:  Phys Med Biol       Date:  2009-09-01       Impact factor: 3.609

8.  Three-dimensional x-ray fluorescence mapping of a gold nanoparticle-loaded phantom.

Authors:  Liqiang Ren; Di Wu; Yuhua Li; Ge Wang; Xizeng Wu; Hong Liu
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

9.  Order of magnitude sensitivity increase in X-ray Fluorescence Computed Tomography (XFCT) imaging with an optimized spectro-spatial detector configuration: theory and simulation.

Authors:  Moiz Ahmad; Magdalena Bazalova; Liangzhong Xiang; Lei Xing
Journal:  IEEE Trans Med Imaging       Date:  2014-05       Impact factor: 10.048

10.  Imaging properties of small-pixel spectroscopic x-ray detectors based on cadmium telluride sensors.

Authors:  Thomas Koenig; Julia Schulze; Marcus Zuber; Kristian Rink; Jochen Butzer; Elias Hamann; Angelica Cecilia; Andreas Zwerger; Alex Fauler; Michael Fiederle; Uwe Oelfke
Journal:  Phys Med Biol       Date:  2012-10-03       Impact factor: 3.609

View more
  1 in total

Review 1.  Tutorial on X-ray photon counting detector characterization.

Authors:  Liqiang Ren; Bin Zheng; Hong Liu
Journal:  J Xray Sci Technol       Date:  2018       Impact factor: 1.535

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.