Experimental and theoretical performance analysis for a CMOS-based high resolution image detector.

Amit Jain1, Daniel R Bednarek1, Stephen Rudin1.   

Abstract

Increasing complexity of endovascular interventional procedures requires superior x-ray imaging quality. Present state-of-the-art x-ray imaging detectors may not be adequate due to their inherent noise and resolution limitations. With recent developments, CMOS based detectors are presenting an option to fulfill the need for better image quality. For this work, a new CMOS detector has been analyzed experimentally and theoretically in terms of sensitivity, MTF and DQE. The detector (Dexela Model 1207, Perkin-Elmer Co., London, UK) features 14-bit image acquisition, a CsI phosphor, 75 µm pixels and an active area of 12 cm × 7 cm with over 30 fps frame rate. This detector has two modes of operations with two different full-well capacities: high and low sensitivity. The sensitivity and instrumentation noise equivalent exposure (INEE) were calculated for both modes. The detector modulation-transfer function (MTF), noise-power spectra (NPS) and detective quantum efficiency (DQE) were measured using an RQA5 spectrum. For the theoretical performance evaluation, a linear cascade model with an added aliasing stage was used. The detector showed excellent linearity in both modes. The sensitivity and the INEE of the detector were found to be 31.55 DN/µR and 0.55 µR in high sensitivity mode, while they were 9.87 DN/µR and 2.77 µR in low sensitivity mode. The theoretical and experimental values for the MTF and DQE showed close agreement with good DQE even at fluoroscopic exposure levels. In summary, the Dexela detector's imaging performance in terms of sensitivity, linear system metrics, and INEE demonstrates that it can overcome the noise and resolution limitations of present state-of-the-art x-ray detectors.

Entities:  

Keywords:  Aliasing; CMOS; DQE; Linear Cascade Model; MTF; X-Ray Imager

Year:  2014        PMID: 25300571      PMCID: PMC4187383          DOI: 10.1117/12.2043053

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  7 in total

1.  A ghost story: spatio-temporal response characteristics of an indirect-detection flat-panel imager.

Authors:  J H Siewerdsen; D A Jaffray
Journal:  Med Phys       Date:  1999-08       Impact factor: 4.071

2.  X-ray image intensifier.

Authors:  S Balter
Journal:  Catheter Cardiovasc Interv       Date:  1999-02       Impact factor: 2.692

3.  A method for measuring the presampled MTF of digital radiographic systems using an edge test device.

Authors:  E Samei; M J Flynn; D A Reimann
Journal:  Med Phys       Date:  1998-01       Impact factor: 4.071

4.  Digital radiology using active matrix readout of amorphous selenium: theoretical analysis of detective quantum efficiency.

Authors:  W Zhao; J A Rowlands
Journal:  Med Phys       Date:  1997-12       Impact factor: 4.071

5.  X-ray imaging using amorphous selenium: inherent spatial resolution.

Authors:  W Que; J A Rowlands
Journal:  Med Phys       Date:  1995-04       Impact factor: 4.071

6.  A spatial-frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging systems.

Authors:  I A Cunningham; M S Westmore; A Fenster
Journal:  Med Phys       Date:  1994-03       Impact factor: 4.071

7.  Endovascular image-guided interventions (EIGIs).

Authors:  Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

  7 in total
  11 in total

1.  Region-of-interest cone beam computed tomography (ROI CBCT) with a high resolution CMOS detector.

Authors:  A Jain; H Takemoto; M D Silver; S V S Nagesh; C N Ionita; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-18

2.  A CMOS-based high resolution fluoroscope (HRF) detector prototype with 49.5 μm pixels for use in endovascular image guided interventions (EIGI).

Authors:  M Russ; A Shankar; S V Setlur Nagesh; C N Ionita; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-09

3.  Quantitative comparison using Generalized Relative Object Detectability (G-ROD) metrics of an amorphous selenium detector with high resolution Microangiographic Fluoroscopes (MAF) and standard flat panel detectors (FPD).

Authors:  M Russ; A Shankar; A Jain; S V Setlur Nagesh; C N Ionita; C Scott; K S Karim; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-22

4.  Evaluation of image quality and task performance for a mobile C-arm with a complementary metal-oxide semiconductor detector.

Authors:  Godwin O Abiola; Niral M Sheth; Wojciech Zbijewski; Matthew W Jacobson; Christopher Bailey; John Filtes; Gerhard Kleinszig; Sebastian K Vogt; Stefan Soellradl; Jens Bialkowski; William S Anderson; Jeffrey H Siewerdsen; Clifford R Weiss
Journal:  J Med Imaging (Bellingham)       Date:  2020-01-24

5.  Anti-scatter grid artifact elimination for high resolution x-ray imaging CMOS detectors.

Authors:  R Rana; V Singh; A Jain; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-18

6.  Theoretical investigation of the noise performance of active pixel imaging arrays based on polycrystalline silicon thin film transistors.

Authors:  Martin Koniczek; Larry E Antonuk; Youcef El-Mohri; Albert K Liang; Qihua Zhao
Journal:  Med Phys       Date:  2017-05-22       Impact factor: 4.071

7.  Focal spot size reduction using asymmetric collimation to enable reduced anode angles with a conventional angiographic x-ray tube for use with high resolution detectors.

Authors:  M Russ; A Shankar; S V Setlur Nagesh; C N Ionita; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-09

8.  Initial investigations of a special high-definition (Hi-Def) zoom capability in a new detector system for neuro-interventional procedures.

Authors:  S V Setlur Nagesh; A Shankar; J Krebs; J Hinaman; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-09

9.  Mobile C-Arm with a CMOS detector: Technical assessment of fluoroscopy and Cone-Beam CT imaging performance.

Authors:  Niral M Sheth; Wojciech Zbijewski; Matthew W Jacobson; Godwin Abiola; Gerhard Kleinszig; Sebastian Vogt; Stefan Soellradl; Jens Bialkowski; William S Anderson; Clifford R Weiss; Greg M Osgood; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2018-11-13       Impact factor: 4.071

10.  Anti-scatter grid artifact elimination for high-resolution x-ray imaging detectors without a prior scatter distribution profile.

Authors:  S V Setlur Nagesh; R Rana; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.