Literature DB >> 25294923

Glucose control in the intensive care unit by use of continuous glucose monitoring: what level of measurement error is acceptable?

Malgorzata E Wilinska1, Roman Hovorka2.   

Abstract

BACKGROUND: Accuracy and frequency of glucose measurement is essential to achieve safe and efficacious glucose control in the intensive care unit. Emerging continuous glucose monitors provide frequent measurements, trending information, and alarms. The objective of this study was to establish the level of accuracy of continuous glucose monitoring (CGM) associated with safe and efficacious glucose control in the intensive care unit.
METHODS: We evaluated 3 established glucose control protocols [Yale, University of Washington, and Normoglycemia in Intensive Care Evaluation and Surviving Using Glucose Algorithm Regulation (NICE-SUGAR)] by use of computer simulations. Insulin delivery was informed by intermittent blood glucose (BG) measurements or CGM levels with an increasing level of measurement error. Measures of glucose control included mean glucose, glucose variability, proportion of time glucose was in target range, and hypoglycemia episodes.
RESULTS: Apart from the Washington protocol, CGM with mean absolute relative deviation (MARD) ≤ 15% resulted in similar mean glucose as with the use of intermittent BG measurements. Glucose variability was also similar between CGM and BG-informed protocols. Frequency and duration of hypoglycemia were not worse by use of CGM with MARD ≤ 10%. Measures of glucose control varied more between protocols than at different levels of the CGM error.
CONCLUSIONS: The efficacy of CGM-informed and BG-informed commonly used glucose protocols is similar, but the risk of hypoglycemia may be reduced by use of CGM with MARD ≤ 10%. Protocol choice has greater influence on glucose control measures than the glucose measurement method.
© 2014 American Association for Clinical Chemistry.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25294923     DOI: 10.1373/clinchem.2014.225326

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  14 in total

1.  Impact of Glucose Meter Error on Glycemic Variability and Time in Target Range During Glycemic Control After Cardiovascular Surgery.

Authors:  Brad S Karon; Jeffrey W Meeusen; Sandra C Bryant
Journal:  J Diabetes Sci Technol       Date:  2015-08-25

2.  Glucose Variability Based on Continuous Glucose Monitoring Assessment Is Associated with Postoperative Complications after Cardiovascular Surgery.

Authors:  Hiroki Sato; Michihiro Hosojima; Tomomi Ishikawa; Kenji Aoki; Takeshi Okamoto; Akihiko Saito; Masanori Tsuchida
Journal:  Ann Thorac Cardiovasc Surg       Date:  2017-07-18       Impact factor: 1.520

3.  Comparison of Accuracy Guidelines for Hospital Glucose Meters.

Authors:  Cynthia Foss Bowman; James H Nichols
Journal:  J Diabetes Sci Technol       Date:  2020-01-25

Review 4.  Toward a Framework for Outcome-Based Analytical Performance Specifications: A Methodology Review of Indirect Methods for Evaluating the Impact of Measurement Uncertainty on Clinical Outcomes.

Authors:  Alison F Smith; Bethany Shinkins; Peter S Hall; Claire T Hulme; Mike P Messenger
Journal:  Clin Chem       Date:  2019-08-23       Impact factor: 8.327

5.  Significant Published Articles for Pharmacy Nutrition Support Practice in 2017.

Authors:  Roland N Dickerson; Vanessa J Kumpf; Angela L Bingham; Allison B Blackmer; Todd W Canada; Lingtak-Neander Chan; Sarah V Cogle; Anne M Tucker
Journal:  Hosp Pharm       Date:  2018-05-30

6.  The impact of measurement frequency on the domains of glycemic control in the critically ill--a Monte Carlo simulation.

Authors:  James S Krinsley; David E Bruns; James C Boyd
Journal:  J Diabetes Sci Technol       Date:  2015-01-06

7.  In Silico Testing of an Artificial-Intelligence-Based Artificial Pancreas Designed for Use in the Intensive Care Unit Setting.

Authors:  Leon DeJournett; Jeremy DeJournett
Journal:  J Diabetes Sci Technol       Date:  2016-11-01

Review 8.  Glucose Control in the ICU: A Continuing Story.

Authors:  Jean-Charles Preiser; J Geoffrey Chase; Roman Hovorka; Jeffrey I Joseph; James S Krinsley; Christophe De Block; Thomas Desaive; Luc Foubert; Pierre Kalfon; Ulrike Pielmeier; Tom Van Herpe; Jan Wernerman
Journal:  J Diabetes Sci Technol       Date:  2016-11-01

Review 9.  Nonadjunctive Use of Continuous Glucose Monitoring for Diabetes Treatment Decisions.

Authors:  Jessica R Castle; Peter G Jacobs
Journal:  J Diabetes Sci Technol       Date:  2016-08-22

10.  Accuracy of Blood Glucose Measurement and Blood Glucose Targets.

Authors:  Gert-Jan Eerdekens; Steffen Rex; Dieter Mesotten
Journal:  J Diabetes Sci Technol       Date:  2020-02-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.