Literature DB >> 27170632

Glucose Control in the ICU: A Continuing Story.

Jean-Charles Preiser1, J Geoffrey Chase2, Roman Hovorka3, Jeffrey I Joseph4, James S Krinsley5, Christophe De Block6, Thomas Desaive7, Luc Foubert8, Pierre Kalfon9, Ulrike Pielmeier10, Tom Van Herpe11, Jan Wernerman12.   

Abstract

In the present era of near-continuous glucose monitoring (CGM) and automated therapeutic closed-loop systems, measures of accuracy and of quality of glucose control need to be standardized for licensing authorities and to enable comparisons across studies and devices. Adequately powered, good quality, randomized, controlled studies are needed to assess the impact of different CGM devices on the quality of glucose control, workload, and costs. The additional effects of continuing glucose control on the general floor after the ICU stay also need to be investigated. Current algorithms need to be adapted and validated for CGM, including effects on glucose variability and workload. Improved collaboration within the industry needs to be encouraged because no single company produces all the necessary components for an automated closed-loop system. Combining glucose measurement with measurement of other variables in 1 sensor may help make this approach more financially viable.
© 2016 Diabetes Technology Society.

Entities:  

Keywords:  continuous glucose control; diabetes; intensive care; time in band

Mesh:

Substances:

Year:  2016        PMID: 27170632      PMCID: PMC5094326          DOI: 10.1177/1932296816648713

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  67 in total

1.  Stochastic targeted (STAR) glycemic control: design, safety, and performance.

Authors:  Alicia Evans; Aaron Le Compte; Chia-Siong Tan; Logan Ward; James Steel; Christopher G Pretty; Sophie Penning; Fatanah Suhaimi; Geoffrey M Shaw; Thomas Desaive; J Geoffrey Chase
Journal:  J Diabetes Sci Technol       Date:  2012-01-01

Review 2.  Clinical practice. Glycemic control in the ICU.

Authors:  Brian P Kavanagh; Karen C McCowen
Journal:  N Engl J Med       Date:  2010-12-23       Impact factor: 91.245

3.  The Glucosafe system for tight glycemic control in critical care: a pilot evaluation study.

Authors:  Ulrike Pielmeier; Steen Andreassen; Brian Juliussen; J Geoffrey Chase; Birgitte Steenfeldt Nielsen; Pernille Haure
Journal:  J Crit Care       Date:  2010-03       Impact factor: 3.425

4.  Use of intensive insulin therapy for the management of glycemic control in hospitalized patients: a clinical practice guideline from the American College of Physicians.

Authors:  Amir Qaseem; Linda L Humphrey; Roger Chou; Vincenza Snow; Paul Shekelle
Journal:  Ann Intern Med       Date:  2011-02-15       Impact factor: 25.391

5.  Glucose control positively influences patient outcome: A retrospective study.

Authors:  Sophie Penning; Chris Pretty; Jean-Charles Preiser; Geoffrey M Shaw; Thomas Desaive; J Geoffrey Chase
Journal:  J Crit Care       Date:  2014-12-31       Impact factor: 3.425

6.  The evaluation of the ability of closed-loop glycemic control device to maintain the blood glucose concentration in intensive care unit patients.

Authors:  Tomoaki Yatabe; Rie Yamazaki; Hiroyuki Kitagawa; Takehiro Okabayashi; Koichi Yamashita; Kazuhiro Hanazaki; Masataka Yokoyama
Journal:  Crit Care Med       Date:  2011-03       Impact factor: 7.598

Review 7.  Guidelines for the use of an insulin infusion for the management of hyperglycemia in critically ill patients.

Authors:  Judith Jacobi; Nicholas Bircher; James Krinsley; Michael Agus; Susan S Braithwaite; Clifford Deutschman; Amado X Freire; Douglas Geehan; Benjamin Kohl; Stanley A Nasraway; Mark Rigby; Karen Sands; Lynn Schallom; Beth Taylor; Guillermo Umpierrez; John Mazuski; Holger Schunemann
Journal:  Crit Care Med       Date:  2012-12       Impact factor: 7.598

8.  Intensive versus conventional insulin therapy: a randomized controlled trial in medical and surgical critically ill patients.

Authors:  Yaseen M Arabi; Ousama C Dabbagh; Hani M Tamim; Abdullah A Al-Shimemeri; Ziad A Memish; Samir H Haddad; Sofia J Syed; Hema R Giridhar; Asgar H Rishu; Mouhamad O Al-Daker; Salim H Kahoul; Riette J Britts; Maram H Sakkijha
Journal:  Crit Care Med       Date:  2008-12       Impact factor: 7.598

9.  Corticosteroid treatment and intensive insulin therapy for septic shock in adults: a randomized controlled trial.

Authors:  Djillali Annane; Alain Cariou; Virginie Maxime; Elie Azoulay; Gilles D'honneur; Jean François Timsit; Yves Cohen; Michel Wolf; Muriel Fartoukh; Christophe Adrie; Charles Santré; Pierre Edouard Bollaert; Armelle Mathonet; Roland Amathieu; Alexis Tabah; Christophe Clec'h; Julien Mayaux; Julie Lejeune; Sylvie Chevret
Journal:  JAMA       Date:  2010-01-27       Impact factor: 56.272

10.  Real-time continuous glucose monitoring in critically ill patients: a prospective randomized trial.

Authors:  Ulrike Holzinger; Joanna Warszawska; Reinhard Kitzberger; Marlene Wewalka; Wolfgang Miehsler; Harald Herkner; Christian Madl
Journal:  Diabetes Care       Date:  2009-12-10       Impact factor: 19.112

View more
  29 in total

1.  Autoregressive Modeling of Drift and Random Error to Characterize a Continuous Intravascular Glucose Monitoring Sensor.

Authors:  Tony Zhou; Jennifer L Dickson; J Geoffrey Chase
Journal:  J Diabetes Sci Technol       Date:  2017-07-14

2.  Dynamic properties of glucose complexity during the course of critical illness: a pilot study.

Authors:  Emmanuel Godat; Jean-Charles Preiser; Jean-Christophe Aude; Pierre Kalfon
Journal:  J Clin Monit Comput       Date:  2019-03-19       Impact factor: 2.502

Review 3.  Designing the Glucose Telemetry for Hospital Management: From Bedside to the Nursing Station.

Authors:  Medha Satyarengga; Tariq Siddiqui; Elias K Spanakis
Journal:  Curr Diab Rep       Date:  2018-08-29       Impact factor: 4.810

4.  Consensus Statement on Inpatient Use of Continuous Glucose Monitoring.

Authors:  Amisha Wallia; Guillermo E Umpierrez; Robert J Rushakoff; David C Klonoff; Daniel J Rubin; Sherita Hill Golden; Curtiss B Cook; Bithika Thompson
Journal:  J Diabetes Sci Technol       Date:  2017-04-21

5.  Glucose Management Technologies for the Critically Ill.

Authors:  Pedro D Salinas; Carlos E Mendez
Journal:  J Diabetes Sci Technol       Date:  2019-01-13

6.  Advancing the Use of CGM Devices in a Non-ICU Setting.

Authors:  Meng Wang; Lakshmi G Singh; Elias K Spanakis
Journal:  J Diabetes Sci Technol       Date:  2019-01-13

Review 7.  Inpatient Continuous Glucose Monitoring and Glycemic Outcomes.

Authors:  David L Levitt; Kristi D Silver; Elias K Spanakis
Journal:  J Diabetes Sci Technol       Date:  2017-03-14

Review 8.  Hypoglycemia Reduction Strategies in the ICU.

Authors:  Susan Shapiro Braithwaite; Dharmesh B Bavda; Thaer Idrees; Faisal Qureshi; Oluwakemi T Soetan
Journal:  Curr Diab Rep       Date:  2017-11-02       Impact factor: 4.810

Review 9.  Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes.

Authors:  David Rodbard
Journal:  Diabetes Technol Ther       Date:  2017-06       Impact factor: 6.118

Review 10.  Updates in Glycemic Management in the Hospital.

Authors:  Wasineenart Mongkolpun; Bruna Provenzano; Jean-Charles Preiser
Journal:  Curr Diab Rep       Date:  2019-11-20       Impact factor: 4.810

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.