Literature DB >> 19798739

New registration algorithm for determining 3D knee kinematics using CT and single-plane fluoroscopy with improved out-of-plane translation accuracy.

Jennifer M Scarvell1, Mark R Pickering, Paul N Smith.   

Abstract

To understand the kinematic effects of surgery, arthroplasty or conservative treatments, a noninvasive system to capture accurate 3D imaging of functional activities in prospective, controlled studies is required. To provide such a technique, a new algorithm was developed to register 3D CT data of normal bones to the same bones in a 2D fluoroscopy frame. The algorithm produces a digitally reconstructed radiograph (DRR) from the CT data and then filters this to produce an edge-enhanced image. The resulting image is then registered with an edge-enhanced version of the fluoroscopy frame using a new similarity measure called Cross-Correlation Residual Entropy (CCRE). The system was evaluated by implanting tantalum beads into three cadaveric knees to act as fiducial markers. The knees were flexed between 0 degrees and 70 degrees , and single-plane fluoroscopy data of the knees were acquired. CT data of the femur and tibia were then individually registered to the fluoroscopy images. No significant measurement bias was observed, and the standard deviation of the error in bead positions was 0.38 mm for in-plane translation and 0.42 degrees for rotation. To determine the accuracy of the registration algorithm for out-of-plane translations, fluoroscopy frames were scaled in size by fixed increments; the average standard deviation of the errors for out-of-plane translation was 0.65 mm. The ability to obtain such accurate 3D motion data from a noninvasive technique will enable prospective, longitudinal, and controlled studies of reconstruction surgery, and conservative management of joint pathologies.

Entities:  

Mesh:

Year:  2010        PMID: 19798739     DOI: 10.1002/jor.21003

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  8 in total

1.  Predicting 3D pose in partially overlapped X-ray images of knee prostheses using model-based Roentgen stereophotogrammetric analysis (RSA).

Authors:  Chi-Pin Hsu; Shang-Chih Lin; Kao-Shang Shih; Chang-Hung Huang; Chian-Her Lee
Journal:  Med Biol Eng Comput       Date:  2014-10-08       Impact factor: 2.602

2.  An automatic 2D-3D image matching method for reproducing spatial knee joint positions using single or dual fluoroscopic images.

Authors:  Zhonglin Zhu; Guoan Li
Journal:  Comput Methods Biomech Biomed Engin       Date:  2011-08-01       Impact factor: 1.763

3.  Accuracy assessment of Tri-plane B-mode ultrasound for non-invasive 3D kinematic analysis of knee joints.

Authors:  Md Abdullah Masum; Mark Pickering; Andrew Lambert; Jennie Scarvell; Paul Smith
Journal:  Biomed Eng Online       Date:  2014-08-26       Impact factor: 2.819

4.  Vertical stiffness is not related to anterior cruciate ligament elongation in professional rugby union players.

Authors:  Benjamin G Serpell; Jennie M Scarvell; Mark R Pickering; Nick B Ball; Diana Perriman; John Warmenhoven; Paul N Smith
Journal:  BMJ Open Sport Exerc Med       Date:  2016-11-01

5.  Comparison of in vivo hindfoot joints motion changes during stance phase between non-flatfoot and stage II adult acquired flatfoot.

Authors:  Zhenhan Deng; Zijun Cai; Siyu Chen; Yan Liu; Fanglin Chen; Zhiqin Deng; Yusheng Li; Jian Xu
Journal:  J Foot Ankle Res       Date:  2022-10-13       Impact factor: 3.050

6.  Reliability of semiautomated computational methods for estimating tibiofemoral contact stress in the Multicenter Osteoarthritis Study.

Authors:  Donald D Anderson; Neil A Segal; Andrew M Kern; Michael C Nevitt; James C Torner; John A Lynch
Journal:  Comput Math Methods Med       Date:  2012-10-14       Impact factor: 2.238

7.  Medial and lateral hamstrings and quadriceps co-activation affects knee joint kinematics and ACL elongation: a pilot study.

Authors:  Benjamin G Serpell; Jennie M Scarvell; Mark R Pickering; Nick B Ball; Phillip Newman; Diana Perriman; John Warmenhoven; Paul N Smith
Journal:  BMC Musculoskelet Disord       Date:  2015-11-12       Impact factor: 2.362

8.  Accurate determination of post-operative 3D component positioning in total knee arthroplasty: the AURORA protocol.

Authors:  Edgar A Wakelin; Linda Tran; Joshua G Twiggs; Willy Theodore; Justin P Roe; Michael I Solomon; Brett A Fritsch; Brad P Miles
Journal:  J Orthop Surg Res       Date:  2018-10-30       Impact factor: 2.359

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.