Literature DB >> 25278515

An SPM8-based approach for attenuation correction combining segmentation and nonrigid template formation: application to simultaneous PET/MR brain imaging.

David Izquierdo-Garcia1, Adam E Hansen2, Stefan Förster3, Didier Benoit2, Sylvia Schachoff3, Sebastian Fürst3, Kevin T Chen4, Daniel B Chonde5, Ciprian Catana6.   

Abstract

UNLABELLED: We present an approach for head MR-based attenuation correction (AC) based on the Statistical Parametric Mapping 8 (SPM8) software, which combines segmentation- and atlas-based features to provide a robust technique to generate attenuation maps (μ maps) from MR data in integrated PET/MR scanners.
METHODS: Coregistered anatomic MR and CT images of 15 glioblastoma subjects were used to generate the templates. The MR images from these subjects were first segmented into 6 tissue classes (gray matter, white matter, cerebrospinal fluid, bone, soft tissue, and air), which were then nonrigidly coregistered using a diffeomorphic approach. A similar procedure was used to coregister the anatomic MR data for a new subject to the template. Finally, the CT-like images obtained by applying the inverse transformations were converted to linear attenuation coefficients to be used for AC of PET data. The method was validated on 16 new subjects with brain tumors (n = 12) or mild cognitive impairment (n = 4) who underwent CT and PET/MR scans. The μ maps and corresponding reconstructed PET images were compared with those obtained using the gold standard CT-based approach and the Dixon-based method available on the Biograph mMR scanner. Relative change (RC) images were generated in each case, and voxel- and region-of-interest-based analyses were performed.
RESULTS: The leave-one-out cross-validation analysis of the data from the 15 atlas-generation subjects showed small errors in brain linear attenuation coefficients (RC, 1.38% ± 4.52%) compared with the gold standard. Similar results (RC, 1.86% ± 4.06%) were obtained from the analysis of the atlas-validation datasets. The voxel- and region-of-interest-based analysis of the corresponding reconstructed PET images revealed quantification errors of 3.87% ± 5.0% and 2.74% ± 2.28%, respectively. The Dixon-based method performed substantially worse (the mean RC values were 13.0% ± 10.25% and 9.38% ± 4.97%, respectively). Areas closer to the skull showed the largest improvement.
CONCLUSION: We have presented an SPM8-based approach for deriving the head μ map from MR data to be used for PET AC in integrated PET/MR scanners. Its implementation is straightforward and requires only the morphologic data acquired with a single MR sequence. The method is accurate and robust, combining the strengths of both segmentation- and atlas-based approaches while minimizing their drawbacks.
© 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

Entities:  

Keywords:  attenuation correction; integrated PET/MRI; segmentation; template

Mesh:

Year:  2014        PMID: 25278515      PMCID: PMC4246705          DOI: 10.2967/jnumed.113.136341

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  29 in total

1.  Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinograms.

Authors:  J Nuyts; P Dupont; S Stroobants; R Benninck; L Mortelmans; P Suetens
Journal:  IEEE Trans Med Imaging       Date:  1999-05       Impact factor: 10.048

2.  MR-based attenuation correction for torso-PET/MR imaging: pitfalls in mapping MR to CT data.

Authors:  Thomas Beyer; Markus Weigert; Harald H Quick; Uwe Pietrzyk; Florian Vogt; Christoph Palm; Gerald Antoch; Stefan P Müller; Andreas Bockisch
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-02-19       Impact factor: 9.236

3.  MRI-based attenuation correction for PET/MRI: a novel approach combining pattern recognition and atlas registration.

Authors:  Matthias Hofmann; Florian Steinke; Verena Scheel; Guillaume Charpiat; Jason Farquhar; Philip Aschoff; Michael Brady; Bernhard Schölkopf; Bernd J Pichler
Journal:  J Nucl Med       Date:  2008-10-16       Impact factor: 10.057

4.  Simultaneous reconstruction of activity and attenuation in time-of-flight PET.

Authors:  Ahmadreza Rezaei; Michel Defrise; Girish Bal; Christian Michel; Maurizio Conti; Charles Watson; Johan Nuyts
Journal:  IEEE Trans Med Imaging       Date:  2012-08-09       Impact factor: 10.048

5.  Completion of a truncated attenuation image from the attenuated PET emission data.

Authors:  Johan Nuyts; Girish Bal; Frank Kehren; Matthias Fenchel; Christian Michel; Charles Watson
Journal:  IEEE Trans Med Imaging       Date:  2012-09-21       Impact factor: 10.048

Review 6.  PET/MRI for neurologic applications.

Authors:  Ciprian Catana; Alexander Drzezga; Wolf-Dieter Heiss; Bruce R Rosen
Journal:  J Nucl Med       Date:  2012-11-09       Impact factor: 10.057

7.  MR-Based PET attenuation correction for PET/MR imaging.

Authors:  Ilja Bezrukov; Frédéric Mantlik; Holger Schmidt; Bernhard Schölkopf; Bernd J Pichler
Journal:  Semin Nucl Med       Date:  2013-01       Impact factor: 4.446

8.  Evaluation of an attenuation correction method for PET/MR imaging of the head based on substitute CT images.

Authors:  Anne Larsson; Adam Johansson; Jan Axelsson; Tufve Nyholm; Thomas Asklund; Katrine Riklund; Mikael Karlsson
Journal:  MAGMA       Date:  2012-09-07       Impact factor: 2.310

9.  Simultaneous MR-compatible emission and transmission imaging for PET using time-of-flight information.

Authors:  Pieter Mollet; Vincent Keereman; Enrico Clementel; Stefaan Vandenberghe
Journal:  IEEE Trans Med Imaging       Date:  2012-09       Impact factor: 10.048

10.  PET/MR imaging of bone lesions--implications for PET quantification from imperfect attenuation correction.

Authors:  Andrei Samarin; Cyrill Burger; Scott D Wollenweber; David W Crook; Irene A Burger; Daniel T Schmid; Gustav K von Schulthess; Felix P Kuhn
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-04-14       Impact factor: 9.236

View more
  88 in total

1.  Sensitivity estimation in time-of-flight list-mode positron emission tomography.

Authors:  J L Herraiz; A Sitek
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

Review 2.  Combined PET/MRI: Multi-modality Multi-parametric Imaging Is Here: Summary Report of the 4th International Workshop on PET/MR Imaging; February 23-27, 2015, Tübingen, Germany.

Authors:  D L Bailey; B J Pichler; B Gückel; H Barthel; A J Beer; J Bremerich; J Czernin; A Drzezga; C Franzius; V Goh; M Hartenbach; H Iida; A Kjaer; C la Fougère; C N Ladefoged; I Law; K Nikolaou; H H Quick; O Sabri; J Schäfer; M Schäfers; H F Wehrl; T Beyer
Journal:  Mol Imaging Biol       Date:  2015-10       Impact factor: 3.488

3.  Feasibility and acceptance of simultaneous amyloid PET/MRI.

Authors:  Lisa Schütz; Donald Lobsien; Dominik Fritzsch; Solveig Tiepolt; Peter Werner; Matthias L Schroeter; Jörg Berrouschot; Dorothee Saur; Swen Hesse; Thies Jochimsen; Michael Rullmann; Bernhard Sattler; Marianne Patt; Hermann-Josef Gertz; Arno Villringer; Joseph Claßen; Karl-Titus Hoffmann; Osama Sabri; Henryk Barthel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-07-19       Impact factor: 9.236

4.  Different partial volume correction methods lead to different conclusions: An (18)F-FDG-PET study of aging.

Authors:  Douglas N Greve; David H Salat; Spencer L Bowen; David Izquierdo-Garcia; Aaron P Schultz; Ciprian Catana; J Alex Becker; Claus Svarer; Gitte M Knudsen; Reisa A Sperling; Keith A Johnson
Journal:  Neuroimage       Date:  2016-02-23       Impact factor: 6.556

5.  Dopamine in the medial amygdala network mediates human bonding.

Authors:  Shir Atzil; Alexandra Touroutoglou; Tali Rudy; Stephanie Salcedo; Ruth Feldman; Jacob M Hooker; Bradford C Dickerson; Ciprian Catana; Lisa Feldman Barrett
Journal:  Proc Natl Acad Sci U S A       Date:  2017-02-13       Impact factor: 11.205

6.  PET Image Reconstruction Using Deep Image Prior.

Authors:  Kuang Gong; Ciprian Catana; Jinyi Qi; Quanzheng Li
Journal:  IEEE Trans Med Imaging       Date:  2018-12-19       Impact factor: 10.048

Review 7.  Machine learning in quantitative PET: A review of attenuation correction and low-count image reconstruction methods.

Authors:  Tonghe Wang; Yang Lei; Yabo Fu; Walter J Curran; Tian Liu; Jonathon A Nye; Xiaofeng Yang
Journal:  Phys Med       Date:  2020-07-29       Impact factor: 2.685

8.  Striatal hypofunction as a neural correlate of mood alterations in chronic pain patients.

Authors:  Minhae Kim; Ishtiaq Mawla; Daniel S Albrecht; Roee Admon; Angel Torrado-Carvajal; Courtney Bergan; Ekaterina Protsenko; Poornima Kumar; Robert R Edwards; Atreyi Saha; Vitaly Napadow; Diego A Pizzagalli; Marco L Loggia
Journal:  Neuroimage       Date:  2020-02-15       Impact factor: 6.556

9.  On the accuracy and reproducibility of a novel probabilistic atlas-based generation for calculation of head attenuation maps on integrated PET/MR scanners.

Authors:  Kevin T Chen; David Izquierdo-Garcia; Clare B Poynton; Daniel B Chonde; Ciprian Catana
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-08-29       Impact factor: 9.236

Review 10.  MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging.

Authors:  David Izquierdo-Garcia; Ciprian Catana
Journal:  PET Clin       Date:  2016-01-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.