Literature DB >> 22948340

Simultaneous MR-compatible emission and transmission imaging for PET using time-of-flight information.

Pieter Mollet1, Vincent Keereman, Enrico Clementel, Stefaan Vandenberghe.   

Abstract

Quantitative positron emission tomography (PET) imaging relies on accurate attenuation correction. Predicting attenuation values from magnetic resonance (MR) images is difficult because MR signals are related to proton density and relaxation properties of tissues. Here, we propose a method to derive the attenuation map from a transmission scan. An annulus transmission source is positioned inside the field-of-view of the PET scanner. First a blank scan is acquired. The patient is injected with FDG and placed inside the scanner. 511-keV photons coming from the patient and the transmission source are acquired simultaneously. Time-of-flight information is used to extract the coincident photons originating from the annulus. The blank and transmission data are compared in an iterative reconstruction method to derive the attenuation map. Simulations with a digital phantom were performed to validate the method. The reconstructed attenuation coefficients differ less than 5% in volumes of interest inside the lungs, bone, and soft tissue. When applying attenuation correction in the reconstruction of the emission data a standardized uptake value error smaller than 9% was obtained for all tissues. In conclusion, our method can reconstruct the attenuation map and the emission data from a simultaneous scan without prior knowledge about the anatomy or the attenuation coefficients of the tissues.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22948340     DOI: 10.1109/TMI.2012.2198831

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  26 in total

1.  Attenuation correction in emission tomography using the emission data--A review.

Authors:  Yannick Berker; Yusheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

2.  Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging.

Authors:  David Izquierdo-Garcia; Stephen J Sawiak; Karin Knesaurek; Jagat Narula; Valentin Fuster; Joseph Machac; Zahi A Fayad
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-03-21       Impact factor: 9.236

3.  Clinical evaluation of TOF versus non-TOF on PET artifacts in simultaneous PET/MR: a dual centre experience.

Authors:  Edwin E G W Ter Voert; Patrick Veit-Haibach; Sangtae Ahn; Florian Wiesinger; M Mehdi Khalighi; Craig S Levin; Andrei H Iagaru; Greg Zaharchuk; Martin Huellner; Gaspar Delso
Journal:  Eur J Nucl Med Mol Imaging       Date:  2017-01-26       Impact factor: 9.236

Review 4.  From simultaneous to synergistic MR-PET brain imaging: A review of hybrid MR-PET imaging methodologies.

Authors:  Zhaolin Chen; Sharna D Jamadar; Shenpeng Li; Francesco Sforazzini; Jakub Baran; Nicholas Ferris; Nadim Jon Shah; Gary F Egan
Journal:  Hum Brain Mapp       Date:  2018-08-04       Impact factor: 5.038

Review 5.  Challenges and current methods for attenuation correction in PET/MR.

Authors:  Vincent Keereman; Pieter Mollet; Yannick Berker; Volkmar Schulz; Stefaan Vandenberghe
Journal:  MAGMA       Date:  2012-08-09       Impact factor: 2.310

6.  PET/MR attenuation correction: where have we come from and where are we going?

Authors:  Dimitris Visvikis; Florian Monnier; Julien Bert; Mathieu Hatt; Hadi Fayad
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-06       Impact factor: 9.236

7.  Joint Reconstruction of Activity and Attenuation in Time-of-Flight PET: A Quantitative Analysis.

Authors:  Ahmadreza Rezaei; Christophe M Deroose; Thomas Vahle; Fernando Boada; Johan Nuyts
Journal:  J Nucl Med       Date:  2018-03-01       Impact factor: 10.057

8.  Improvement of attenuation correction in time-of-flight PET/MR imaging with a positron-emitting source.

Authors:  Pieter Mollet; Vincent Keereman; Jason Bini; David Izquierdo-Garcia; Zahi A Fayad; Stefaan Vandenberghe
Journal:  J Nucl Med       Date:  2014-01-16       Impact factor: 10.057

Review 9.  MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging.

Authors:  David Izquierdo-Garcia; Ciprian Catana
Journal:  PET Clin       Date:  2016-01-26

Review 10.  Advances in time-of-flight PET.

Authors:  Suleman Surti; Joel S Karp
Journal:  Phys Med       Date:  2016-01-06       Impact factor: 2.685

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.