Literature DB >> 23014717

Completion of a truncated attenuation image from the attenuated PET emission data.

Johan Nuyts1, Girish Bal, Frank Kehren, Matthias Fenchel, Christian Michel, Charles Watson.   

Abstract

Positron emission tomographs (PETs) are currently almost exclusively designed as hybrid systems. The current standard is the PET/CT combination, while prototype PET/MRI systems are being studied by several research groups. One problem in these systems is that the transaxial field-of-view of the second system is smaller than that of the PET camera and does not provide complete attenuation data. Because this second system provides the image for PET attenuation and scatter correction, the smaller FOV causes truncation of the attenuation map, producing bias in the attenuation corrected activity image. In this paper, we propose a maximum-a-posteriori algorithm for estimating the missing part of the attenuation map from the PET emission data. The method is evaluated on five artificially truncated 18F-FDGPET/CT studies, where it reduced the error on the reconstructed PET activities from 20% to less than 7%. The results on a PET/MRI patient study with 18F-FDG are presented as well.

Entities:  

Mesh:

Year:  2012        PMID: 23014717     DOI: 10.1109/TMI.2012.2220376

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  38 in total

1.  Can PET be performed without an attenuation scan?

Authors:  Colin Jones; Ran Klein
Journal:  J Nucl Cardiol       Date:  2015-09-04       Impact factor: 5.952

2.  Attenuation correction in emission tomography using the emission data--A review.

Authors:  Yannick Berker; Yusheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

3.  Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging.

Authors:  David Izquierdo-Garcia; Stephen J Sawiak; Karin Knesaurek; Jagat Narula; Valentin Fuster; Joseph Machac; Zahi A Fayad
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-03-21       Impact factor: 9.236

4.  Quantitative simultaneous positron emission tomography and magnetic resonance imaging.

Authors:  Jinsong Ouyang; Yoann Petibon; Chuan Huang; Timothy G Reese; Aleksandra L Kolnick; Georges El Fakhri
Journal:  J Med Imaging (Bellingham)       Date:  2014-11-03

5.  Automatic correction of dental artifacts in PET/MRI.

Authors:  Claes N Ladefoged; Flemming L Andersen; Sune H Keller; Thomas Beyer; Ian Law; Liselotte Højgaard; Sune Darkner; Francois Lauze
Journal:  J Med Imaging (Bellingham)       Date:  2015-06-09

6.  PET/MR attenuation correction: where have we come from and where are we going?

Authors:  Dimitris Visvikis; Florian Monnier; Julien Bert; Mathieu Hatt; Hadi Fayad
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-06       Impact factor: 9.236

Review 7.  Advances in PET/MR instrumentation and image reconstruction.

Authors:  Jorge Cabello; Sibylle I Ziegler
Journal:  Br J Radiol       Date:  2016-07-22       Impact factor: 3.039

8.  Accurate PET/MR quantification using time of flight MLAA image reconstruction.

Authors:  R Boellaard; M B M Hofman; O S Hoekstra; A A Lammertsma
Journal:  Mol Imaging Biol       Date:  2014-08       Impact factor: 3.488

Review 9.  MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging.

Authors:  David Izquierdo-Garcia; Ciprian Catana
Journal:  PET Clin       Date:  2016-01-26

10.  Impact of improved attenuation correction featuring a bone atlas and truncation correction on PET quantification in whole-body PET/MR.

Authors:  Mark Oehmigen; Maike E Lindemann; Marcel Gratz; Julian Kirchner; Verena Ruhlmann; Lale Umutlu; Jan Ole Blumhagen; Matthias Fenchel; Harald H Quick
Journal:  Eur J Nucl Med Mol Imaging       Date:  2017-11-09       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.