Literature DB >> 25277608

National trends in the utilization of short-term mechanical circulatory support: incidence, outcomes, and cost analysis.

Robert Stretch1, Christopher M Sauer1, David D Yuh2, Pramod Bonde3.   

Abstract

BACKGROUND: The number of alternatives to intra-aortic balloon counterpulsation in the treatment of anticipated and established acute circulatory failure is growing. Despite the clinical importance and significant cost of short-term mechanical circulatory support (MCS) devices, the state of their present use has not been analyzed on a national scale.
OBJECTIVES: The purpose of this study was to characterize the demographics, treatment practices, survival rates, and cost of short-term MCS.
METHODS: In this serial cross-sectional study, we analyzed all adult patients receiving short-term MCS in the United States from 2004 to 2011 by using the Nationwide Inpatient Sample from the Healthcare Cost and Utilization Project.
RESULTS: From 2007 to 2011, use of percutaneous devices for short-term MCS increased by 1,511% compared with a 101% increase in nonpercutaneous devices. Mortality rates declined over this period (p for trend = 0.027) from 41.1% in 2004 to 2007 to 33.4% in 2008 to 2011. A similar trend was observed for the subset of patients with cardiogenic shock, decreasing from 51.6% to 43.1% (p for trend = 0.012). Hospital costs also declined over this period (p for trend = 0.011). Multivariable analysis revealed balloon pumps (odds ratio [OR]: 2.00; 95% confidence interval [CI]: 1.58 to 2.52), coagulopathy (OR: 2.35; 95% CI: 1.88 to 2.94), and cardiopulmonary resuscitation (OR: 3.50; 95% CI: 2.20 to 5.57) before short-term MCS were among the most significant predictors of mortality.
CONCLUSIONS: Use of short-term MCS in the United States has increased rapidly, whereas rates of in-hospital mortality have decreased. These changes have taken place in the context of declining hospital costs associated with short-term MCS.
Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  heart failure; left ventricular assist device; percutaneous devices; shock

Mesh:

Year:  2014        PMID: 25277608     DOI: 10.1016/j.jacc.2014.07.958

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  96 in total

Review 1.  Options for temporary mechanical circulatory support.

Authors:  Areo Saffarzadeh; Pramod Bonde
Journal:  J Thorac Dis       Date:  2015-12       Impact factor: 2.895

2.  INTERMACS profiles and modifiers: Heterogeneity of patient classification and the impact of modifiers on predicting patient outcome.

Authors:  Jennifer Cowger; Palak Shah; John Stulak; Simon Maltais; Keith D Aaronson; James K Kirklin; Francis D Pagani; Christopher Salerno
Journal:  J Heart Lung Transplant       Date:  2015-11-06       Impact factor: 10.247

Review 3.  Cellular responses to mild heat stress.

Authors:  H G Park; S I Han; S Y Oh; H S Kang
Journal:  Cell Mol Life Sci       Date:  2005-01       Impact factor: 9.261

Review 4.  Phagocytosis of apoptotic cells: a matter of balance.

Authors:  C J G de Almeida; R Linden
Journal:  Cell Mol Life Sci       Date:  2005-07       Impact factor: 9.261

Review 5.  Management of refractory cardiogenic shock.

Authors:  Alex Reyentovich; Maya H Barghash; Judith S Hochman
Journal:  Nat Rev Cardiol       Date:  2016-06-30       Impact factor: 32.419

6.  Incidence and clinical outcomes of bleeding complications and acute limb ischemia in STEMI and cardiogenic shock.

Authors:  Mohit Pahuja; Sagar Ranka; Omar Chehab; Tushar Mishra; Emmanuel Akintoye; Oluwole Adegbala; Ahmed S Yassin; Tomo Ando; Katherine L Thayer; Palak Shah; Carey D Kimmelstiel; Payam Salehi; Navin K Kapur
Journal:  Catheter Cardiovasc Interv       Date:  2020-05-30       Impact factor: 2.692

Review 7.  [Mechanical support in cardiogenic shock].

Authors:  T Graf; H Thiele
Journal:  Herz       Date:  2015-04       Impact factor: 1.443

Review 8.  Cardiogenic Shock in Patients with Advanced Chronic Heart Failure.

Authors:  Cesar Y Guerrero-Miranda; Shelley A Hall
Journal:  Methodist Debakey Cardiovasc J       Date:  2020 Jan-Mar

Review 9.  Percutaneous Ventricular Assist Devices: A Novel Approach in the Management of Patients With Acute Cardiogenic Shock.

Authors:  Kevin Ergle; Parham Parto; Selim R Krim
Journal:  Ochsner J       Date:  2016

10.  Abdominal Positioning of the Next-Generation Intra-Aortic Fluid Entrainment Pump (Aortix) Improves Cardiac Output in a Swine Model of Heart Failure.

Authors:  Shiva K Annamalai; Michele L Esposito; Lara A Reyelt; Peter Natov; Lena E Jorde; Richard H Karas; Navin K Kapur
Journal:  Circ Heart Fail       Date:  2018-08       Impact factor: 8.790

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.