Literature DB >> 26793330

Options for temporary mechanical circulatory support.

Areo Saffarzadeh1, Pramod Bonde1.   

Abstract

Temporary mechanical circulatory support (MCS) refers to a group of devices generally used for less than 30 days to maintain adequate organ perfusion by compensating for a failure of the pumping mechanism of the heart. The increased availability and rapid adoption of new temporary MCS strategies necessitate physicians to become familiar with devices placed both percutaneously and via median sternotomy. This review will examine the different options for commonly used temporary MCS devices including intra-aortic balloon pumps (IABPs), veno-arterial-extracorporeal membrane oxygenation (VA-ECMO), TandemHeart(®) (CardiacAssist, Pittsburg, PA, USA) Impella(®) and BVS 5000(®) (both Abiomed Inc., Danvers, MA, USA), CentriMag(®) and Thoratec percutaneous ventricular assist device (pVAD)(®) (both Thoratec Corporation, Pleasanton, CA, USA). A specific emphasis will be made to describe relevant mechanisms of action, standard placement strategies, hemodynamic effects, relevant contraindications and complications, and important daily management considerations.

Entities:  

Keywords:  CentriMag; Left ventricular assist device (LVAD); TandemHeart; biventricular assist device (BIVAD); extracorporeal membrane oxygenation (ECMO); percutaneous ventricular assist device (pVAD); right ventricular assist device (RVAD)

Year:  2015        PMID: 26793330      PMCID: PMC4703696          DOI: 10.3978/j.issn.2072-1439.2015.09.14

Source DB:  PubMed          Journal:  J Thorac Dis        ISSN: 2072-1439            Impact factor:   2.895


  22 in total

Review 1.  Ventricular assist device therapy for heart failure--past, present, and future.

Authors:  Lavanya Bellumkonda; Pramod Bonde
Journal:  Int Anesthesiol Clin       Date:  2012

2.  The percutaneous ventricular assist device in severe refractory cardiogenic shock.

Authors:  Biswajit Kar; Igor D Gregoric; Sukhdeep S Basra; Gary M Idelchik; Pranav Loyalka
Journal:  J Am Coll Cardiol       Date:  2010-10-14       Impact factor: 24.094

3.  Complications of extracorporeal membrane oxygenation for treatment of cardiogenic shock and cardiac arrest: a meta-analysis of 1,866 adult patients.

Authors:  Richard Cheng; Rory Hachamovitch; Michelle Kittleson; Jignesh Patel; Francisco Arabia; Jaime Moriguchi; Fardad Esmailian; Babak Azarbal
Journal:  Ann Thorac Surg       Date:  2013-11-08       Impact factor: 4.330

4.  Severe intra-aortic balloon pump complications: a single-center 12-year experience.

Authors:  Luca Severi; Paola Vaccaro; Marco Covotta; Giovanni Landoni; Rosalba Lembo; Antonio Menichetti
Journal:  J Cardiothorac Vasc Anesth       Date:  2012-03-22       Impact factor: 2.628

5.  A prospective, randomized clinical trial of hemodynamic support with Impella 2.5 versus intra-aortic balloon pump in patients undergoing high-risk percutaneous coronary intervention: the PROTECT II study.

Authors:  William W O'Neill; Neal S Kleiman; Jeffrey Moses; Jose P S Henriques; Simon Dixon; Joseph Massaro; Igor Palacios; Brijeshwar Maini; Suresh Mulukutla; Vladimír Dzavík; Jeffrey Popma; Pamela S Douglas; Magnus Ohman
Journal:  Circulation       Date:  2012-08-30       Impact factor: 29.690

6.  Extracorporeal membrane oxygenation use has increased by 433% in adults in the United States from 2006 to 2011.

Authors:  Christopher M Sauer; David D Yuh; Pramod Bonde
Journal:  ASAIO J       Date:  2015 Jan-Feb       Impact factor: 2.872

7.  Intraaortic balloon support for myocardial infarction with cardiogenic shock.

Authors:  Holger Thiele; Uwe Zeymer; Franz-Josef Neumann; Miroslaw Ferenc; Hans-Georg Olbrich; Jörg Hausleiter; Gert Richardt; Marcus Hennersdorf; Klaus Empen; Georg Fuernau; Steffen Desch; Ingo Eitel; Rainer Hambrecht; Jörg Fuhrmann; Michael Böhm; Henning Ebelt; Steffen Schneider; Gerhard Schuler; Karl Werdan
Journal:  N Engl J Med       Date:  2012-08-26       Impact factor: 91.245

8.  Mechanically unloading the left ventricle before coronary reperfusion reduces left ventricular wall stress and myocardial infarct size.

Authors:  Navin K Kapur; Vikram Paruchuri; Jose Angel Urbano-Morales; Emily E Mackey; Gerard H Daly; Xiaoying Qiao; Natesa Pandian; George Perides; Richard H Karas
Journal:  Circulation       Date:  2013-06-13       Impact factor: 29.690

9.  Percutaneous placement of an intra-aortic balloon pump in the left axillary/subclavian position provides safe, ambulatory long-term support as bridge to heart transplantation.

Authors:  Jerry D Estep; Andrea M Cordero-Reyes; Arvind Bhimaraj; Barry Trachtenberg; Nashwa Khalil; Matthias Loebe; Brian Bruckner; Carlos M Orrego; Jean Bismuth; Neal S Kleiman; Guillermo Torre-Amione
Journal:  JACC Heart Fail       Date:  2013-09-11       Impact factor: 12.035

Review 10.  Temporary mechanical circulatory support: a review of the options, indications, and outcomes.

Authors:  Nisha A Gilotra; Gerin R Stevens
Journal:  Clin Med Insights Cardiol       Date:  2015-02-03
View more
  8 in total

1.  Development of a real-time and quantitative thrombus sensor for an extracorporeal centrifugal blood pump by near-infrared light.

Authors:  Daisuke Sakota; Tatsuki Fujiwara; Katsuhiro Ohuchi; Katsuyuki Kuwana; Hiroyuki Yamazaki; Ryo Kosaka; Masahiro Nishida; Tomohiro Mizuno; Hirokuni Arai; Osamu Maruyama
Journal:  Biomed Opt Express       Date:  2017-12-12       Impact factor: 3.732

2.  EEG Artifact Versus Subclinical Status Epilepticus in a Patient Following Cardiac Arrest.

Authors:  Jean E Cibula; Daniel S Demos; Brenda G Fahy
Journal:  Neurocrit Care       Date:  2018-08       Impact factor: 3.210

Review 3.  The Surgeon's Role in Cardiogenic Shock.

Authors:  Alexandra E Sperry; Matthew Williams; Pavan Atluri; Wilson Y Szeto; Marisa Cevasco; Christian A Bermudez; Michael A Acker; Michael Ibrahim
Journal:  Curr Heart Fail Rep       Date:  2021-05-06

4.  Temporary assist device support for the right ventricle: pre-implant and post-implant challenges.

Authors:  Michael Dandel; Roland Hetzer
Journal:  Heart Fail Rev       Date:  2018-03       Impact factor: 4.214

Review 5.  Mechanical Circulatory Support for Decompensated Heart Failure.

Authors:  Tarique Al Musa; Colin Dominic Chue; Hoong Sern Lim
Journal:  Curr Heart Fail Rep       Date:  2017-10

Review 6.  Mechanical Circulatory Support to Treat Pulmonary Embolism: Venoarterial Extracorporeal Membrane Oxygenation and Right Ventricular Assist Devices.

Authors:  Aneil Bhalla; Robert Attaran
Journal:  Tex Heart Inst J       Date:  2020-06-01

7.  Minimal invasive temporary percutaneous right ventricular circulatory support after left ventricular assist device implantation.

Authors:  Ruslan Natanov; Marcel Ricklefs; Nodir Madrahimov; Felix Fleissner; Axel Haverich; Christian Kühn
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-10-29

Review 8.  Facilitating noncardiac surgery for the patient with left ventricular assist device: A guide for the anesthesiologist.

Authors:  Kai-Yin Hwang; Nian-Chih Hwang
Journal:  Ann Card Anaesth       Date:  2018 Oct-Dec
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.