Literature DB >> 25270602

Integrated RF/shim coil array for parallel reception and localized B0 shimming in the human brain.

Trong-Kha Truong1, Dean Darnell2, Allen W Song2.   

Abstract

The purpose of this work was to develop a novel integrated radiofrequency and shim (RF/shim) coil array that can perform parallel reception and localized B0 shimming in the human brain with the same coils, thereby maximizing both the signal-to-noise ratio and shimming efficiency. A 32-channel receive-only head coil array was modified to enable both RF currents (for signal reception) and direct currents (for B0 shimming) to flow in individual coil elements. Its in vivo performance was assessed in the frontal brain region, which is affected by large susceptibility-induced B0 inhomogeneities. The coil modifications did not reduce their quality factor or signal-to-noise ratio. Axial B0 maps and echo-planar images acquired in vivo with direct currents optimized to shim specific slices showed substantially reduced B0 inhomogeneities and image distortions in the frontal brain region. The B0 root-mean-square error in the anterior half of the brain was reduced by 60.3% as compared to that obtained with second-order spherical harmonic shimming. These results demonstrate that the integrated RF/shim coil array can perform parallel reception and localized B0 shimming in the human brain and provide a much more effective shimming than conventional spherical harmonic shimming alone, without taking up additional space in the magnet bore and without compromising the signal-to-noise ratio or shimming performance.
Copyright © 2014 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  B(0) shimming; Coil array; Human brain; RF coil; Shim coil

Mesh:

Year:  2014        PMID: 25270602      PMCID: PMC4312247          DOI: 10.1016/j.neuroimage.2014.09.052

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  11 in total

1.  Three-dimensional numerical simulations of susceptibility-induced magnetic field inhomogeneities in the human head.

Authors:  Trong-Kha Truong; Bradley D Clymer; Donald W Chakeres; Petra Schmalbrock
Journal:  Magn Reson Imaging       Date:  2002-12       Impact factor: 2.546

2.  Centiles for adult head circumference.

Authors:  K M Bushby; T Cole; J N Matthews; J A Goodship
Journal:  Arch Dis Child       Date:  1992-10       Impact factor: 3.791

3.  Mitigation of susceptibility-induced signal loss in neuroimaging using localized shim coils.

Authors:  Jung-Jiin Hsu; Gary H Glover
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

4.  Dynamic shim updating: a new approach towards optimized whole brain shimming.

Authors:  A M Blamire; D L Rothman; T Nixon
Journal:  Magn Reson Med       Date:  1996-07       Impact factor: 4.668

5.  A new approach to shimming: the dynamically controlled adaptive current network.

Authors:  Chad T Harris; William B Handler; Blaine A Chronik
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

6.  Multicoil shimming of the mouse brain.

Authors:  Christoph Juchem; Peter B Brown; Terence W Nixon; Scott McIntyre; Douglas L Rothman; Robin A de Graaf
Journal:  Magn Reson Med       Date:  2011-03-25       Impact factor: 4.668

7.  Magnet field profiling: analysis and correcting coil design.

Authors:  F Roméo; D I Hoult
Journal:  Magn Reson Med       Date:  1984-03       Impact factor: 4.668

8.  Integrated parallel reception, excitation, and shimming (iPRES).

Authors:  Hui Han; Allen W Song; Trong-Kha Truong
Journal:  Magn Reson Med       Date:  2013-04-29       Impact factor: 4.668

9.  Dynamic multi-coil shimming of the human brain at 7 T.

Authors:  Christoph Juchem; Terence W Nixon; Scott McIntyre; Vincent O Boer; Douglas L Rothman; Robin A de Graaf
Journal:  J Magn Reson       Date:  2011-07-23       Impact factor: 2.229

10.  A 64-channel 3T array coil for accelerated brain MRI.

Authors:  Boris Keil; James N Blau; Stephan Biber; Philipp Hoecht; Veneta Tountcheva; Kawin Setsompop; Christina Triantafyllou; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2012-07-31       Impact factor: 4.668

View more
  29 in total

1.  Modeling of active shimming of metallic needles for interventional MRI.

Authors:  Saikat Sengupta
Journal:  Magn Reson Med       Date:  2020-06-29       Impact factor: 4.668

2.  Rapid multi-orientation quantitative susceptibility mapping.

Authors:  Berkin Bilgic; Luke Xie; Russell Dibb; Christian Langkammer; Aysegul Mutluay; Huihui Ye; Jonathan R Polimeni; Jean Augustinack; Chunlei Liu; Lawrence L Wald; Kawin Setsompop
Journal:  Neuroimage       Date:  2015-08-12       Impact factor: 6.556

3.  3D-MB-MUSE: A robust 3D multi-slab, multi-band and multi-shot reconstruction approach for ultrahigh resolution diffusion MRI.

Authors:  Iain P Bruce; Hing-Chiu Chang; Christopher Petty; Nan-Kuei Chen; Allen W Song
Journal:  Neuroimage       Date:  2017-07-18       Impact factor: 6.556

4.  Integrated radio-frequency/wireless coil design for simultaneous MR image acquisition and wireless communication.

Authors:  Dean Darnell; Jonathan Cuthbertson; Fraser Robb; Allen W Song; Trong-Kha Truong
Journal:  Magn Reson Med       Date:  2018-09-14       Impact factor: 4.668

5.  A 32-channel combined RF and B0 shim array for 3T brain imaging.

Authors:  Jason P Stockmann; Thomas Witzel; Boris Keil; Jonathan R Polimeni; Azma Mareyam; Cristen LaPierre; Kawin Setsompop; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2015-02-17       Impact factor: 4.668

6.  Adaptive integrated parallel reception, excitation, and shimming (iPRES-A) with microelectromechanical systems switches.

Authors:  Dean Darnell; Yixin Ma; Hongyuan Wang; Fraser Robb; Allen W Song; Trong-Kha Truong
Journal:  Magn Reson Med       Date:  2017-11-16       Impact factor: 4.668

Review 7.  Proton MR spectroscopy in the breast: Technical innovations and clinical applications.

Authors:  Reza Fardanesh; Maria Adele Marino; Daly Avendano; Doris Leithner; Katja Pinker; Sunitha B Thakur
Journal:  J Magn Reson Imaging       Date:  2019-03-07       Impact factor: 4.813

Review 8.  Magnetic Resonance Imaging technology-bridging the gap between noninvasive human imaging and optical microscopy.

Authors:  Jonathan R Polimeni; Lawrence L Wald
Journal:  Curr Opin Neurobiol       Date:  2018-05-11       Impact factor: 6.627

9.  High-fidelity, high-isotropic-resolution diffusion imaging through gSlider acquisition with B 1 + and T1 corrections and integrated ΔB0 /Rx shim array.

Authors:  Congyu Liao; Jason Stockmann; Qiyuan Tian; Berkin Bilgic; Nicolas S Arango; Mary Kate Manhard; Susie Y Huang; William A Grissom; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2019-08-01       Impact factor: 4.668

10.  Slice-selective adiabatic magnetization T2 -preparation (SAMPA) for efficient T2 -weighted imaging at ultrahigh field strengths.

Authors:  Hadrien Dyvorne; Priti Balchandani
Journal:  Magn Reson Med       Date:  2015-12-01       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.