Literature DB >> 12591571

Three-dimensional numerical simulations of susceptibility-induced magnetic field inhomogeneities in the human head.

Trong-Kha Truong1, Bradley D Clymer, Donald W Chakeres, Petra Schmalbrock.   

Abstract

Three-dimensional numerical simulations of the static magnetic field in the human head were carried out to assess the field inhomogeneity due to magnetic susceptibility differences at tissue interfaces. We used a finite difference method and magnetic permeability distributions obtained by segmentation of computed tomography images. Computations were carried out for four models, consisting of the head and the neck; the head, neck, and shoulders; the head, neck, and thorax; and the head tilted backwards, including the neck and the shoulders. Considerable magnetic field inhomogeneities were observed in the inferior frontal lobes and inferior temporal lobes, particularly near the sphenoid sinus and the temporal bones. Air/tissue interfaces at the shoulders were found to induce substantial magnetic field inhomogeneities in the occipital lobes and the cerebellum, whereas air/tissue interfaces in the lungs appeared to have less influence on the magnetic field in the brain. Tilting the head backwards could significantly reduce the field inhomogeneities superior to the planum sphenoidale as well as in the occipital lobes and the cerebellum.

Entities:  

Mesh:

Year:  2002        PMID: 12591571     DOI: 10.1016/s0730-725x(02)00601-x

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  21 in total

1.  The clinical relevance and scientific potential of ultra high-field-strength MR imaging.

Authors:  Stephen Chan
Journal:  AJNR Am J Neuroradiol       Date:  2002-10       Impact factor: 3.825

2.  Combining prospective motion correction and distortion correction for EPI: towards a comprehensive correction of motion and susceptibility-induced artifacts.

Authors:  Rainer Boegle; Julian Maclaren; Maxim Zaitsev
Journal:  MAGMA       Date:  2010-08-06       Impact factor: 2.310

3.  Degraded water suppression in small volume ¹H MRS due to localised shimming.

Authors:  Asa Carlsson; Maria Ljungberg; Göran Starck; Eva Forssell-Aronsson
Journal:  MAGMA       Date:  2011-01-06       Impact factor: 2.310

4.  Usefulness of IDEAL T2 imaging for homogeneous fat suppression and reducing susceptibility artefacts in brachial plexus MRI at 3.0 T.

Authors:  Alberto Tagliafico; Bianca Bignotti; Giulio Tagliafico; Carlo Martinoli
Journal:  Radiol Med       Date:  2015-08-08       Impact factor: 3.469

5.  Computer-generated fMRI phantoms with motion-distortion interaction.

Authors:  Ning Xu; J Michael Fitzpatrick; Yong Li; Benoit M Dawant; David R Pickens; Victoria L Morgan
Journal:  Magn Reson Imaging       Date:  2007-06-21       Impact factor: 2.546

6.  Concurrent correction of geometric distortion and motion using the map-slice-to-volume method in echo-planar imaging.

Authors:  Desmond T B Yeo; Jeffrey A Fessler; Boklye Kim
Journal:  Magn Reson Imaging       Date:  2008-02-15       Impact factor: 2.546

7.  Functional imaging with MR T1 contrast: a feasibility study with blood-pool contrast agent.

Authors:  Agata Majos; Piotr Bogorodzki; Ewa Piatkowska-Janko; Tomasz Wolak; Robert Kurjata; Ludomir Stefańczyk
Journal:  Eur Radiol       Date:  2008-11-06       Impact factor: 5.315

8.  Geometric distortion correction for echo planar images using nonrigid registration with spatially varying scale.

Authors:  Yong Li; Ning Xu; J Michael Fitzpatrick; Benoit M Dawant
Journal:  Magn Reson Imaging       Date:  2008-05-21       Impact factor: 2.546

9.  Computation of Magnetic Field Distortions and Impact on T2*-weighted MRI with Application to Magnetic Susceptibility Parameter Estimation.

Authors:  Corey E Cruttenden; Xiao-Hong Zhu; Wei Chen; Rajesh Rajamani
Journal:  Biomed Phys Eng Express       Date:  2018-06-14

Review 10.  Numerical field calculations considering the human subject for engineering and safety assurance in MRI.

Authors:  Christopher M Collins
Journal:  NMR Biomed       Date:  2009-11       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.