Literature DB >> 25263944

Evaluation of segmented 3D acquisition schemes for whole-brain high-resolution arterial spin labeling at 3 T.

Marta Vidorreta1, Evelyne Balteau, Ze Wang, Enrico De Vita, María A Pastor, David L Thomas, John A Detre, María A Fernández-Seara.   

Abstract

Recent technical developments have significantly increased the signal-to-noise ratio (SNR) of arterial spin labeled (ASL) perfusion MRI. Despite this, typical ASL acquisitions still employ large voxel sizes. The purpose of this work was to implement and evaluate two ASL sequences optimized for whole-brain high-resolution perfusion imaging, combining pseudo-continuous ASL (pCASL), background suppression (BS) and 3D segmented readouts, with different in-plane k-space trajectories. Identical labeling and BS pulses were implemented for both sequences. Two segmented 3D readout schemes with different in-plane trajectories were compared: Cartesian (3D GRASE) and spiral (3D RARE Stack-Of-Spirals). High-resolution perfusion images (2 × 2 × 4 mm(3) ) were acquired in 15 young healthy volunteers with the two ASL sequences at 3 T. The quality of the perfusion maps was evaluated in terms of SNR and gray-to-white matter contrast. Point-spread-function simulations were carried out to assess the impact of readout differences on the effective resolution. The combination of pCASL, in-plane segmented 3D readouts and BS provided high-SNR high-resolution ASL perfusion images of the whole brain. Although both sequences produced excellent image quality, the 3D RARE Stack-Of-Spirals readout yielded higher temporal and spatial SNR than 3D GRASE (spatial SNR = 8.5 ± 2.8 and 3.7 ± 1.4; temporal SNR = 27.4 ± 12.5 and 15.6 ± 7.6, respectively) and decreased through-plane blurring due to its inherent oversampling of the central k-space region, its reduced effective TE and shorter total readout time, at the expense of a slight increase in the effective in-plane voxel size.
Copyright © 2014 John Wiley & Sons, Ltd.

Entities:  

Keywords:  arterial spin labeling; cerebral blood flow; high-resolution ASL; perfusion imaging; segmented readouts; spiral imaging

Mesh:

Substances:

Year:  2014        PMID: 25263944      PMCID: PMC4233410          DOI: 10.1002/nbm.3201

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  38 in total

1.  New approach to gridding using regularization and estimation theory.

Authors:  Daniel Rosenfeld
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

2.  Whole-brain 3D perfusion MRI at 3.0 T using CASL with a separate labeling coil.

Authors:  S Lalith Talagala; Frank Q Ye; Patrick J Ledden; Scott Chesnick
Journal:  Magn Reson Med       Date:  2004-07       Impact factor: 4.668

Review 3.  Spiral imaging in fMRI.

Authors:  Gary H Glover
Journal:  Neuroimage       Date:  2011-10-20       Impact factor: 6.556

4.  Continuous arterial spin labeling perfusion measurements using single shot 3D GRASE at 3 T.

Authors:  María A Fernández-Seara; Ze Wang; Jiongjiong Wang; Heng-Yi Rao; Matthias Guenther; David A Feinberg; John A Detre
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

5.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application].

Authors:  J I Jackson; C H Meyer; D G Nishimura; A Macovski
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

6.  Measurement error.

Authors:  J M Bland; D G Altman
Journal:  BMJ       Date:  1996-06-29

7.  Measuring signal-to-noise ratios in MR imaging.

Authors:  L Kaufman; D M Kramer; L E Crooks; D A Ortendahl
Journal:  Radiology       Date:  1989-10       Impact factor: 11.105

Review 8.  Applications of arterial spin labeled MRI in the brain.

Authors:  John A Detre; Hengyi Rao; Danny J J Wang; Yu Fen Chen; Ze Wang
Journal:  J Magn Reson Imaging       Date:  2012-01-13       Impact factor: 4.813

9.  Minimizing acquisition time of arterial spin labeling at 3T.

Authors:  María A Fernández-Seara; Brian L Edlow; Angela Hoang; Jiongjiong Wang; David A Feinberg; John A Detre
Journal:  Magn Reson Med       Date:  2008-06       Impact factor: 4.668

10.  Human whole blood T2 relaxometry at 3 Tesla.

Authors:  Jean J Chen; G Bruce Pike
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

View more
  16 in total

1.  Effects of systematic partial volume errors on the estimation of gray matter cerebral blood flow with arterial spin labeling MRI.

Authors:  Jan Petr; Henri J M M Mutsaerts; Enrico De Vita; Rebecca M E Steketee; Marion Smits; Aart J Nederveen; Frank Hofheinz; Jörg van den Hoff; Iris Asllani
Journal:  MAGMA       Date:  2018-06-18       Impact factor: 2.310

2.  MRI of cerebral micro-vascular flow patterns: A multi-direction diffusion-weighted ASL approach.

Authors:  J A Wells; D L Thomas; T Saga; J Kershaw; I Aoki
Journal:  J Cereb Blood Flow Metab       Date:  2016-01-01       Impact factor: 6.200

3.  3D-accelerated, stack-of-spirals acquisitions and reconstruction of arterial spin labeling MRI.

Authors:  Yulin V Chang; Marta Vidorreta; Ze Wang; John A Detre
Journal:  Magn Reson Med       Date:  2016-11-03       Impact factor: 4.668

4.  Self-navigation for 3D multishot EPI with data-reference.

Authors:  Steen Moeller; Sudhir Ramanna; Christophe Lenglet; Pramod K Pisharady; Edward J Auerbach; Lance Delabarre; Xiaoping Wu; Mehmet Akcakaya; Kamil Ugurbil
Journal:  Magn Reson Med       Date:  2020-03-02       Impact factor: 4.668

5.  Whole-brain background-suppressed pCASL MRI with 1D-accelerated 3D RARE Stack-Of-Spirals readout.

Authors:  Marta Vidorreta; Ze Wang; Yulin V Chang; David A Wolk; María A Fernández-Seara; John A Detre
Journal:  PLoS One       Date:  2017-08-24       Impact factor: 3.240

6.  Study protocol: Insight 46 - a neuroscience sub-study of the MRC National Survey of Health and Development.

Authors:  Christopher A Lane; Thomas D Parker; Dave M Cash; Kirsty Macpherson; Elizabeth Donnachie; Heidi Murray-Smith; Anna Barnes; Suzie Barker; Daniel G Beasley; Jose Bras; David Brown; Ninon Burgos; Michelle Byford; M Jorge Cardoso; Ana Carvalho; Jessica Collins; Enrico De Vita; John C Dickson; Norah Epie; Miklos Espak; Susie M D Henley; Chandrashekar Hoskote; Michael Hutel; Jana Klimova; Ian B Malone; Pawel Markiewicz; Andrew Melbourne; Marc Modat; Anette Schrag; Sachit Shah; Nikhil Sharma; Carole H Sudre; David L Thomas; Andrew Wong; Hui Zhang; John Hardy; Henrik Zetterberg; Sebastien Ourselin; Sebastian J Crutch; Diana Kuh; Marcus Richards; Nick C Fox; Jonathan M Schott
Journal:  BMC Neurol       Date:  2017-04-18       Impact factor: 2.474

7.  Three-dimensional Pseudo-continuous Arterial Spin-labeling Using Turbo-spin Echo with Pseudo-steady State Readout: A Comparison with Other Major Readout Methods.

Authors:  Suzuko Aoike; Hiroyuki Sugimori; Noriyuki Fujima; Yuriko Suzuki; Yukie Shimizu; Akira Suwa; Kinya Ishizaka; Kohsuke Kudo
Journal:  Magn Reson Med Sci       Date:  2018-10-12       Impact factor: 2.471

8.  Arterial spin labeling MR image denoising and reconstruction using unsupervised deep learning.

Authors:  Kuang Gong; Paul Han; Georges El Fakhri; Chao Ma; Quanzheng Li
Journal:  NMR Biomed       Date:  2019-12-22       Impact factor: 4.044

9.  Spatial coefficient of variation in pseudo-continuous arterial spin labeling cerebral blood flow images as a hemodynamic measure for cerebrovascular steno-occlusive disease: A comparative 15O positron emission tomography study.

Authors:  Masanobu Ibaraki; Kazuhiro Nakamura; Hideto Toyoshima; Kazuhiro Takahashi; Keisuke Matsubara; Atsushi Umetsu; Josef Pfeuffer; Hideto Kuribayashi; Toshibumi Kinoshita
Journal:  J Cereb Blood Flow Metab       Date:  2018-06-05       Impact factor: 6.200

10.  Perfusion and apparent oxygenation in the human placenta (PERFOX).

Authors:  Jana Hutter; Anita A Harteveld; Laurence H Jackson; Suzanne Franklin; Clemens Bos; Matthias J P van Osch; Jonathan O'Muircheartaigh; Alison Ho; Lucy Chappell; Joseph V Hajnal; Mary Rutherford; Enrico De Vita
Journal:  Magn Reson Med       Date:  2019-08-21       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.