Literature DB >> 16193469

Continuous arterial spin labeling perfusion measurements using single shot 3D GRASE at 3 T.

María A Fernández-Seara1, Ze Wang, Jiongjiong Wang, Heng-Yi Rao, Matthias Guenther, David A Feinberg, John A Detre.   

Abstract

Single shot 3D GRASE is less sensitive to field inhomogeneity and susceptibility effects than gradient echo based fast imaging sequences while preserving the acquisition speed. In this study, a continuous arterial spin labeling (CASL) pulse was added prior to the single shot 3D GRASE readout and quantitative perfusion measurements were carried out at 3 T, at rest and during functional activation. The sequence performance was evaluated by comparison with a CASL sequence with EPI readout. It is shown that perfusion measurements using CASL GRASE can be performed safely on humans at 3 T without exceeding the current RF power deposition limits. The maps of resting cerebral blood flow generated from the GRASE images are comparable to those obtained with the 2D EPI readout, albeit with better coverage in the orbitofrontal cortex. The sequence proved effective for functional imaging, yielding time series of images with improved temporal SNR with respect to EPI and group activation maps with increased significance levels. The method was further improved using parallel imaging techniques to provide increased spatial resolution and better separation of the gray-white matter cerebral blood flow maps. (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16193469     DOI: 10.1002/mrm.20674

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  43 in total

1.  Whole-brain cerebral blood flow mapping using 3D echo planar imaging and pulsed arterial tagging.

Authors:  Neville D Gai; S Lalith Talagala; John A Butman
Journal:  J Magn Reson Imaging       Date:  2011-02       Impact factor: 4.813

2.  Arterial spin labeling in neuroimaging.

Authors:  Sasitorn Petcharunpaisan; Joana Ramalho; Mauricio Castillo
Journal:  World J Radiol       Date:  2010-10-28

3.  Optimization of background suppression for arterial spin labeling perfusion imaging.

Authors:  Nasim Maleki; Weiying Dai; David C Alsop
Journal:  MAGMA       Date:  2011-10-19       Impact factor: 2.310

4.  Nonlinear magnetic field gradients can reduce SAR in flow-driven arterial spin labeling measurements.

Authors:  Kenneth I Marro; Donghoon Lee; Outi M Hyyti
Journal:  J Magn Reson       Date:  2006-12-18       Impact factor: 2.229

5.  Imaging mesial temporal lobe activation during scene encoding: comparison of fMRI using BOLD and arterial spin labeling.

Authors:  María A Fernández-Seara; Jiongjiong Wang; Ze Wang; Marc Korczykowski; Matthias Guenther; David A Feinberg; John A Detre
Journal:  Hum Brain Mapp       Date:  2007-12       Impact factor: 5.038

6.  Empirical optimization of ASL data analysis using an ASL data processing toolbox: ASLtbx.

Authors:  Ze Wang; Geoffrey K Aguirre; Hengyi Rao; Jiongjiong Wang; María A Fernández-Seara; Anna R Childress; John A Detre
Journal:  Magn Reson Imaging       Date:  2007-09-10       Impact factor: 2.546

Review 7.  Clinical neuroimaging using arterial spin-labeled perfusion magnetic resonance imaging.

Authors:  Ronald L Wolf; John A Detre
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

8.  Reduced distortion artifact whole brain CBF mapping using blip-reversed non-segmented 3D echo planar imaging with pseudo-continuous arterial spin labeling.

Authors:  Neville D Gai; Yi Yu Chou; Dzung Pham; John A Butman
Journal:  Magn Reson Imaging       Date:  2017-09-01       Impact factor: 2.546

9.  Structural Correlation-based Outlier Rejection (SCORE) algorithm for arterial spin labeling time series.

Authors:  Sudipto Dolui; Ze Wang; Russell T Shinohara; David A Wolk; John A Detre
Journal:  J Magn Reson Imaging       Date:  2016-08-29       Impact factor: 4.813

Review 10.  Perfusion MRI: the five most frequently asked technical questions.

Authors:  Marco Essig; Mark S Shiroishi; Thanh Binh Nguyen; Marc Saake; James M Provenzale; David Enterline; Nicoletta Anzalone; Arnd Dörfler; Alex Rovira; Max Wintermark; Meng Law
Journal:  AJR Am J Roentgenol       Date:  2013-01       Impact factor: 3.959

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.