Literature DB >> 27813164

3D-accelerated, stack-of-spirals acquisitions and reconstruction of arterial spin labeling MRI.

Yulin V Chang1, Marta Vidorreta2, Ze Wang3, John A Detre1,2.   

Abstract

PURPOSE: The goal of this study was to develop a 3D acceleration and reconstruction method to improve image quality and resolution of background-suppressed arterial spin-labeled perfusion MRI.
METHODS: Accelerated acquisition was implemented in all three k-space dimensions in a stack-of-spirals readout using variable density spirals and partition undersampling. A single 3D self-consistent parallel imaging (SPIRiT) kernel was calibrated and iteratively applied to reconstruct each imaging volume. Whole-brain (including cerebellum) perfusion imaging was obtained at 3-mm isotropic resolution (nominal) using single- and 2-shot acquisitions and at 2-mm isotropic resolution (nominal) using four-shot acquisitions, achieving effective acceleration factors between 5.5 and 6.6. The signal-to-noise (SNR) performance of 3D SPIRiT was evaluated. The temporal SNR (tSNR) of the cerebral blood flow (CBF) maps and the gray/white matter CBF ratios were quantified.
RESULTS: The readout of the arterial spin labeling (ASL) sequence was significantly shortened with acceleration. The CBF values were consistent between accelerated and fully sampled ASL. With shorter spiral interleaves and shorter echo trains, the accelerated images demonstrated reduced blurring and signal dropout in regions with high susceptibility gradients, resulting in improved image quality and increased gray/white matter CBF ratios. The shortened readout was accompanied by a corresponding decrease in tSNR.
CONCLUSION: The 3D acceleration and reconstruction allow a rapid whole-brain readout that improved the quality of ASL perfusion imaging. Magn Reson Med 78:1405-1419, 2017.
© 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  SNR; SPIRiT; arterial spin labeling; image blurring; iterative reconstruction; multiple pseudo replica; non-Cartesian; perfusion; tSNR

Mesh:

Substances:

Year:  2016        PMID: 27813164      PMCID: PMC5515691          DOI: 10.1002/mrm.26549

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  62 in total

1.  Variable density randomized stack of spirals (VDR-SoS) for compressive sensing MRI.

Authors:  Giuseppe Valvano; Nicola Martini; Luigi Landini; Maria Filomena Santarelli
Journal:  Magn Reson Med       Date:  2015-07-29       Impact factor: 4.668

2.  How long to scan? The relationship between fMRI temporal signal to noise ratio and necessary scan duration.

Authors:  Kevin Murphy; Jerzy Bodurka; Peter A Bandettini
Journal:  Neuroimage       Date:  2006-11-22       Impact factor: 6.556

3.  2D partially parallel imaging with k-space surrounding neighbors-based data reconstruction.

Authors:  Ze Wang; María A Fernández-Seara
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

4.  On optimality of parallel MRI reconstruction in k-space.

Authors:  Alexey A Samsonov
Journal:  Magn Reson Med       Date:  2008-01       Impact factor: 4.668

5.  Fast three dimensional magnetic resonance imaging.

Authors:  P Irarrazabal; D G Nishimura
Journal:  Magn Reson Med       Date:  1995-05       Impact factor: 4.668

6.  A variable flip angle-based method for reducing blurring in 3D GRASE ASL.

Authors:  Xiaoyun Liang; Alan Connelly; Jacques-Donald Tournier; Fernando Calamante
Journal:  Phys Med Biol       Date:  2014-08-29       Impact factor: 3.609

7.  Fast l₁-SPIRiT compressed sensing parallel imaging MRI: scalable parallel implementation and clinically feasible runtime.

Authors:  Mark Murphy; Marcus Alley; James Demmel; Kurt Keutzer; Shreyas Vasanawala; Michael Lustig
Journal:  IEEE Trans Med Imaging       Date:  2012-02-15       Impact factor: 10.048

Review 8.  Arterial spin labeling blood flow MRI: its role in the early characterization of Alzheimer's disease.

Authors:  David C Alsop; Weiying Dai; Murray Grossman; John A Detre
Journal:  J Alzheimers Dis       Date:  2010       Impact factor: 4.472

9.  Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions.

Authors:  Philip M Robson; Aaron K Grant; Ananth J Madhuranthakam; Riccardo Lattanzi; Daniel K Sodickson; Charles A McKenzie
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

Review 10.  The cerebellum and cognitive function: 25 years of insight from anatomy and neuroimaging.

Authors:  Randy L Buckner
Journal:  Neuron       Date:  2013-10-30       Impact factor: 17.173

View more
  9 in total

1.  Controlling T2 blurring in 3D RARE arterial spin labeling acquisition through optimal combination of variable flip angles and k-space filtering.

Authors:  Li Zhao; Ching-Di Chang; David C Alsop
Journal:  Magn Reson Med       Date:  2018-02-09       Impact factor: 4.668

2.  Highly-accelerated volumetric brain examination using optimized wave-CAIPI encoding.

Authors:  Daniel Polak; Stephen Cauley; Susie Y Huang; Maria Gabriela Longo; John Conklin; Berkin Bilgic; Ned Ohringer; Esther Raithel; Peter Bachert; Lawrence L Wald; Kawin Setsompop
Journal:  J Magn Reson Imaging       Date:  2019-02-08       Impact factor: 4.813

3.  Laminar perfusion imaging with zoomed arterial spin labeling at 7 Tesla.

Authors:  Xingfeng Shao; Fanhua Guo; Qinyang Shou; Kai Wang; Kay Jann; Lirong Yan; Arthur W Toga; Peng Zhang; Danny J J Wang
Journal:  Neuroimage       Date:  2021-11-12       Impact factor: 7.400

4.  Time-encoded golden angle radial arterial spin labeling: Simultaneous acquisition of angiography and perfusion data.

Authors:  Merlijn C E van der Plas; Sophie Schmid; Maarten J Versluis; Thomas W Okell; Matthias J P van Osch
Journal:  NMR Biomed       Date:  2021-05-03       Impact factor: 4.478

5.  Whole-brain background-suppressed pCASL MRI with 1D-accelerated 3D RARE Stack-Of-Spirals readout.

Authors:  Marta Vidorreta; Ze Wang; Yulin V Chang; David A Wolk; María A Fernández-Seara; John A Detre
Journal:  PLoS One       Date:  2017-08-24       Impact factor: 3.240

6.  Characterizing a perfusion-based periventricular small vessel region of interest.

Authors:  Sudipto Dolui; Dylan Tisdall; Marta Vidorreta; David R Jacobs; Ilya M Nasrallah; R Nick Bryan; David A Wolk; John A Detre
Journal:  Neuroimage Clin       Date:  2019-06-12       Impact factor: 4.881

7.  Robust single-shot acquisition of high resolution whole brain ASL images by combining time-dependent 2D CAPIRINHA sampling with spatio-temporal TGV reconstruction.

Authors:  Stefan M Spann; Xingfeng Shao; Danny Jj Wang; Christoph S Aigner; Matthias Schloegl; Kristian Bredies; Rudolf Stollberger
Journal:  Neuroimage       Date:  2019-11-09       Impact factor: 7.400

Review 8.  Recent Technical Developments in ASL: A Review of the State of the Art.

Authors:  Luis Hernandez-Garcia; Verónica Aramendía-Vidaurreta; Divya S Bolar; Weiying Dai; Maria A Fernández-Seara; Jia Guo; Ananth J Madhuranthakam; Henk Mutsaerts; Jan Petr; Qin Qin; Jonas Schollenberger; Yuriko Suzuki; Manuel Taso; David L Thomas; Matthias J P van Osch; Joseph Woods; Moss Y Zhao; Lirong Yan; Ze Wang; Li Zhao; Thomas W Okell
Journal:  Magn Reson Med       Date:  2022-08-19       Impact factor: 3.737

9.  Rotated spiral RARE for high spatial and temporal resolution volumetric arterial spin labeling acquisition.

Authors:  Fanny Munsch; Manuel Taso; Li Zhao; R Marc Lebel; Arnaud Guidon; John A Detre; David C Alsop
Journal:  Neuroimage       Date:  2020-09-12       Impact factor: 7.400

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.