Literature DB >> 25251933

Increased SNR efficiency in velocity selective arterial spin labeling using multiple velocity selective saturation modules (mm-VSASL).

Jia Guo1, Eric C Wong2,3.   

Abstract

PURPOSE: Velocity-selective arterial spin labeling (VSASL) is theoretically insensitive to transit delay (TD) effects. However, it uses saturation instead of inversion, resulting in compromised signal to noise ratio (SNR). In this study we explore the use of multiple velocity-selective saturation (VSS) modules in VSASL (mm-VSASL) to improve SNR.
METHODS: Theoretical SNR efficiency improvement and optimized parameters were calculated from simulations for mm-VSASL. VSASL with two VSS modules (VSASL-2VSS) was implemented to measure cerebral blood flow in vivo, compared with conventional VSASL (VSASL-1VSS), pulsed ASL (PASL), and pseudo-continuous ASL (PCASL). TDs and bolus durations (BDs) were measured to validate the simulations and to examine the TD sensitivity of these preparations.
RESULTS: Compared with VSASL-1VSS, VSASL-2VSS achieved a significant improvement of SNR (22.1 ± 1.9%, P = 1.7 × 10(-6) ) in vivo, consistent with a 22.7% improvement predicted from simulations. The SNR was comparable to or higher (in gray matter, P = 4.3 × 10(-3) ) than that using PCASL. VSASL was experimentally verified to have minimal TD effects.
CONCLUSION: Utilizing multiple VSS modules can improve the SNR efficiency of VSASL. Mm-VSASL may result in an SNR that is comparable to or even higher than that of PCASL in applications where long postlabeling delays are required.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  arterial spin labeling; perfusion; transit delay; velocity-selective ASL; velocity-selective saturation

Mesh:

Substances:

Year:  2014        PMID: 25251933      PMCID: PMC4369468          DOI: 10.1002/mrm.25462

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  29 in total

1.  Evaluation of systematic quantification errors in velocity-selective arterial spin labeling of the brain.

Authors:  Guillaume Duhamel; Cédric de Bazelaire; David C Alsop
Journal:  Magn Reson Med       Date:  2003-07       Impact factor: 4.668

Review 2.  Diffusion MR imaging: clinical applications.

Authors:  D Le Bihan; R Turner; P Douek; N Patronas
Journal:  AJR Am J Roentgenol       Date:  1992-09       Impact factor: 3.959

3.  Magnetic resonance imaging of perfusion using spin inversion of arterial water.

Authors:  D S Williams; J A Detre; J S Leigh; A P Koretsky
Journal:  Proc Natl Acad Sci U S A       Date:  1992-01-01       Impact factor: 11.205

4.  Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping.

Authors:  S G Kim
Journal:  Magn Reson Med       Date:  1995-09       Impact factor: 4.668

5.  AFNI: software for analysis and visualization of functional magnetic resonance neuroimages.

Authors:  R W Cox
Journal:  Comput Biomed Res       Date:  1996-06

6.  Different apparent diffusion coefficient: water content correlations of gray and white matter during early ischemia.

Authors:  T Kuroiwa; T Nagaoka; M Ueki; I Yamada; N Miyasaka; H Akimoto
Journal:  Stroke       Date:  1998-04       Impact factor: 7.914

7.  Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling.

Authors:  E C Wong; R B Buxton; L R Frank
Journal:  NMR Biomed       Date:  1997 Jun-Aug       Impact factor: 4.044

8.  Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow.

Authors:  D C Alsop; J A Detre
Journal:  J Cereb Blood Flow Metab       Date:  1996-11       Impact factor: 6.200

9.  Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques.

Authors:  F Q Ye; V S Mattay; P Jezzard; J A Frank; D R Weinberger; A C McLaughlin
Journal:  Magn Reson Med       Date:  1997-02       Impact factor: 4.668

10.  Qualitative mapping of cerebral blood flow and functional localization with echo-planar MR imaging and signal targeting with alternating radio frequency.

Authors:  R R Edelman; B Siewert; D G Darby; V Thangaraj; A C Nobre; M M Mesulam; S Warach
Journal:  Radiology       Date:  1994-08       Impact factor: 11.105

View more
  15 in total

Review 1.  CEST, ASL, and magnetization transfer contrast: How similar pulse sequences detect different phenomena.

Authors:  Linda Knutsson; Jiadi Xu; André Ahlgren; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2018-05-30       Impact factor: 4.668

2.  Pseudo-asymmetry of cerebral blood flow in arterial spin labeling caused by unilateral fetal-type circle of Willis: Technical limitation or a way to better understanding physiological variations of cerebral perfusion and improving arterial spin labeling acquisition?

Authors:  B Law-Ye; B Geerts; D Galanaud; D Dormont; N Pyatigorskaya
Journal:  J Cereb Blood Flow Metab       Date:  2016-06-02       Impact factor: 6.200

Review 3.  Arterial spin labeling for the measurement of cerebral perfusion and angiography.

Authors:  Peter Jezzard; Michael A Chappell; Thomas W Okell
Journal:  J Cereb Blood Flow Metab       Date:  2017-11-23       Impact factor: 6.200

4.  Quantitative measurement of cerebral blood volume using velocity-selective pulse trains.

Authors:  Dexiang Liu; Feng Xu; Doris D Lin; Peter C M van Zijl; Qin Qin
Journal:  Magn Reson Med       Date:  2016-10-31       Impact factor: 4.668

5.  Predicting 15O-Water PET cerebral blood flow maps from multi-contrast MRI using a deep convolutional neural network with evaluation of training cohort bias.

Authors:  Jia Guo; Enhao Gong; Audrey P Fan; Maged Goubran; Mohammad M Khalighi; Greg Zaharchuk
Journal:  J Cereb Blood Flow Metab       Date:  2019-11-13       Impact factor: 6.200

6.  Improved velocity-selective-inversion arterial spin labeling for cerebral blood flow mapping with 3D acquisition.

Authors:  Dapeng Liu; Feng Xu; Wenbo Li; Peter C van Zijl; Doris D Lin; Qin Qin
Journal:  Magn Reson Med       Date:  2020-05-13       Impact factor: 4.668

7.  Wedge-shaped slice-selective adiabatic inversion pulse for controlling temporal width of bolus in pulsed arterial spin labeling.

Authors:  Jia Guo; Richard B Buxton; Eric C Wong
Journal:  Magn Reson Med       Date:  2015-10-09       Impact factor: 4.668

8.  Velocity-selective-inversion prepared arterial spin labeling.

Authors:  Qin Qin; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2015-10-28       Impact factor: 4.668

9.  Spatial dependency and the role of local susceptibility for velocity selective arterial spin labeling (VS-ASL) relative tagging efficiency using accelerated 3D radial sampling with a BIR-8 preparation.

Authors:  James H Holmes; Mu-Lan Jen; Laura B Eisenmenger; Tilman Schubert; Patrick A Turski; Kevin M Johnson
Journal:  Magn Reson Med       Date:  2021-02-21       Impact factor: 3.737

10.  The dorsal posterior insula is not an island in pain but subserves a fundamental role - Response to: "Evidence against pain specificity in the dorsal posterior insula" by Davis et al.

Authors:  Andrew R Segerdahl; Melvin Mezue; Thomas W Okell; John T Farrar; Irene Tracey
Journal:  F1000Res       Date:  2015-11-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.