Literature DB >> 1729691

Magnetic resonance imaging of perfusion using spin inversion of arterial water.

D S Williams1, J A Detre, J S Leigh, A P Koretsky.   

Abstract

A technique has been developed for proton magnetic resonance imaging (MRI) of perfusion, using water as a freely diffusable tracer, and its application to the measurement of cerebral blood flow (CBF) in the rat is demonstrated. The method involves labeling the inflowing water proton spins in the arterial blood by inverting them continuously at the neck region and observing the effects of inversion on the intensity of brain MRI. Solution to the Bloch equations, modified to include the effects of flow, allows regional perfusion rates to be measured from an image with spin inversion, a control image, and a T1 image. Continuous spin inversion labeling the arterial blood water was accomplished, using principles of adiabatic fast passage by applying continuous-wave radiofrequency power in the presence of a magnetic field gradient in the direction of arterial flow. In the detection slice used to measure perfusion, whole brain CBF averaged 1.39 +/- 0.19 ml.g-1.min-1 (mean +/- SEM, n = 5). The technique's sensitivity to changes in CBF was measured by using graded hypercarbia, a condition that is known to increase brain perfusion. CBF vs. pCO2 data yield a best-fit straight line described by CBF (ml.g-1.min-1) = 0.052pCO2 (mm Hg) - 0.173, in excellent agreement with values in the literature. Finally, perfusion images of a freeze-injured rat brain have been obtained, demonstrating the technique's ability to detect regional abnormalities in perfusion.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1729691      PMCID: PMC48206          DOI: 10.1073/pnas.89.1.212

Source DB:  PubMed          Journal:  Proc Natl Acad Sci U S A        ISSN: 0027-8424            Impact factor:   11.205


  18 in total

1.  A venous outflow method for continuously monitoring cerebral blood flow in the rat.

Authors:  S Morii; A C Ngai; K R Ko; H R Winn
Journal:  Am J Physiol       Date:  1986-02

2.  Nonoxidative glucose consumption during focal physiologic neural activity.

Authors:  P T Fox; M E Raichle; M A Mintun; C Dence
Journal:  Science       Date:  1988-07-22       Impact factor: 47.728

3.  Does mental activity change the oxidative metabolism of the brain?

Authors:  P E Roland; L Eriksson; S Stone-Elander; L Widen
Journal:  J Neurosci       Date:  1987-08       Impact factor: 6.167

4.  Projection angiograms of blood labeled by adiabatic fast passage.

Authors:  W T Dixon; L N Du; D D Faul; M Gado; S Rossnick
Journal:  Magn Reson Med       Date:  1986-06       Impact factor: 4.668

5.  What is the correct value for the brain--blood partition coefficient for water?

Authors:  P Herscovitch; M E Raichle
Journal:  J Cereb Blood Flow Metab       Date:  1985-03       Impact factor: 6.200

6.  A method for determining blood flow and oxygen consumption in the rat brain.

Authors:  B Nilsson; B K Siesjö
Journal:  Acta Physiol Scand       Date:  1976-01

7.  Deuterium nuclear magnetic resonance measurements of blood flow and tissue perfusion employing 2H2O as a freely diffusible tracer.

Authors:  J J Ackerman; C S Ewy; N N Becker; R A Shalwitz
Journal:  Proc Natl Acad Sci U S A       Date:  1987-06       Impact factor: 11.205

8.  Concurrent measurements of cerebral blood flow, sodium, lactate, and high-energy phosphate metabolism using 19F, 23Na, 1H, and 31P nuclear magnetic resonance spectroscopy.

Authors:  S M Eleff; M D Schnall; L Ligetti; M Osbakken; V H Subramanian; B Chance; J S Leigh
Journal:  Magn Reson Med       Date:  1988-08       Impact factor: 4.668

9.  Cerebral blood flow measured by NMR indicator dilution in cats.

Authors:  J R Ewing; C A Branch; J A Helpern; M B Smith; S M Butt; K M Welch
Journal:  Stroke       Date:  1989-02       Impact factor: 7.914

10.  Measurement of cerebral blood flow in rat brain by 19F-NMR detection of trifluoromethane washout.

Authors:  J A Detre; C J Eskey; A P Koretsky
Journal:  Magn Reson Med       Date:  1990-07       Impact factor: 4.668

View more
  463 in total

1.  Penumbra detection using PWI/DWI mismatch MRI in a rat stroke model with and without comorbidity: comparison of methods.

Authors:  Emma Reid; Delyth Graham; M Rosario Lopez-Gonzalez; William M Holmes; I Mhairi Macrae; Christopher McCabe
Journal:  J Cereb Blood Flow Metab       Date:  2012-06-06       Impact factor: 6.200

2.  Quantitative analysis of arterial spin labeling FMRI data using a general linear model.

Authors:  Luis Hernandez-Garcia; Hesamoddin Jahanian; Daniel B Rowe
Journal:  Magn Reson Imaging       Date:  2010-04-24       Impact factor: 2.546

3.  Association cortex hypoperfusion in mild dementia with Lewy bodies: a potential indicator of cholinergic dysfunction?

Authors:  Tamara G Fong; Sharon K Inouye; Weiying Dai; Daniel Z Press; David C Alsop
Journal:  Brain Imaging Behav       Date:  2011-03       Impact factor: 3.978

4.  Cerebral Blood Flow Is Associated with Diagnostic Class and Cognitive Decline in Alzheimer's Disease.

Authors:  Wenna Duan; Parshant Sehrawat; Arvind Balachandrasekaran; Ashish B Bhumkar; Paresh B Boraste; James T Becker; Lewis H Kuller; Oscar L Lopez; H Michael Gach; Weiying Dai
Journal:  J Alzheimers Dis       Date:  2020       Impact factor: 4.472

5.  Simultaneous measurement of cerebral blood flow and transit time with turbo dynamic arterial spin labeling (Turbo-DASL): application to functional studies.

Authors:  Yuguang Meng; Ping Wang; Seong-Gi Kim
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

6.  Unique in utero identification of fetuses in multifetal mouse pregnancies by placental bidirectional arterial spin labeling MRI.

Authors:  Reut Avni; Tal Raz; Inbal E Biton; Vyacheslav Kalchenko; Joel R Garbow; Michal Neeman
Journal:  Magn Reson Med       Date:  2011-12-08       Impact factor: 4.668

7.  Arterial spin labeling measurements of cerebral perfusion territories in experimental ischemic stroke.

Authors:  Renata F Leoni; Fernando F Paiva; Byeong-Teck Kang; Erica C Henning; George C Nascimento; Alberto Tannús; Dráulio B De Araújo; Afonso C Silva
Journal:  Transl Stroke Res       Date:  2011-11-16       Impact factor: 6.829

8.  Reduced distortion artifact whole brain CBF mapping using blip-reversed non-segmented 3D echo planar imaging with pseudo-continuous arterial spin labeling.

Authors:  Neville D Gai; Yi Yu Chou; Dzung Pham; John A Butman
Journal:  Magn Reson Imaging       Date:  2017-09-01       Impact factor: 2.546

9.  Simultaneous magnetic resonance angiography and perfusion (MRAP) measurement: initial application in lower extremity skeletal muscle.

Authors:  Katherine L Wright; Nicole Seiberlich; John A Jesberger; Dean A Nakamoto; Raymond F Muzic; Mark A Griswold; Vikas Gulani
Journal:  J Magn Reson Imaging       Date:  2013-02-06       Impact factor: 4.813

Review 10.  Current trends and challenges in MRI acquisitions to investigate brain function.

Authors:  Bradley P Sutton; Cheng Ouyang; Dimitrios C Karampinos; Gregory A Miller
Journal:  Int J Psychophysiol       Date:  2009-02-21       Impact factor: 2.997

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.