Literature DB >> 25247944

Metal artifact reduction software used with abdominopelvic dual-energy CT of patients with metal hip prostheses: assessment of image quality and clinical feasibility.

Seung Chol Han1, Yong Eun Chung, Young Han Lee, Kwan Kyu Park, Myeong Jin Kim, Ki Whang Kim.   

Abstract

OBJECTIVE: The objective of our study was to determine the feasibility of using Metal Artifact Reduction (MAR) software for abdominopelvic dual-energy CT in patients with metal hip prostheses.
MATERIALS AND METHODS: This retrospective study included 33 patients (male-female ratio, 19:14; mean age, 63.7 years) who received total hip replacements and 20 patients who did not have metal prostheses as the control group. All of the patients underwent dual-energy CT. The quality of the images reconstructed using the MAR algorithm and of those reconstructed using the standard reconstruction was evaluated in terms of the visibility of the bladder wall, pelvic sidewall, rectal shelf, and bone-prosthesis interface and the overall diagnostic image quality with a 4-point scale. The mean and SD attenuation values in Hounsfield units were measured in the bladder, pelvic sidewall, and rectal shelf. For validation of the MAR interpolation algorithm, pelvis phantoms with small bladder "lesions" and metal hip prostheses were made, and images of the phantoms both with and without MAR reconstruction were evaluated.
RESULTS: Image quality was significantly better with MAR reconstruction than without at all sites except the rectal shelf, where the image quality either had not changed or had worsened after MAR reconstruction. The mean attenuation value was changed after MAR reconstruction to its original expected value at the pelvic sidewall (p < 0.001) and inside the bladder (p < 0.001). The SD attenuation value was significantly decreased after MAR reconstruction at the pelvic sidewall (p = 0.019) but did not show significant differences at the bladder (p = 0.173) or rectal shelf (p = 0.478). In the phantom study, all lesions obscured by metal artifacts on the standard reconstruction images were visualized after MAR reconstruction; however, new artifacts had developed in other parts of the MAR reconstruction images.
CONCLUSION: The use of MAR software with dual-energy CT decreases metal artifacts and increases diagnostic confidence in the assessment of the pelvic cavity but also introduces new artifacts that can obscure pelvic structures.

Entities:  

Keywords:  Metal Artifact Reduction software; abdominal dual-energy CT; metal hip prosthesis; pelvic cavity; phantom

Mesh:

Substances:

Year:  2014        PMID: 25247944     DOI: 10.2214/AJR.13.10980

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  21 in total

1.  Metal Artifact Reduction in Head CT Performed for Patients with Deep Brain Stimulation Devices: Effectiveness of a Single-Energy Metal Artifact Reduction Algorithm.

Authors:  Y Nagayama; S Tanoue; S Oda; D Sakabe; T Emoto; M Kidoh; H Uetani; A Sasao; T Nakaura; O Ikeda; K Yamada; Y Yamashita
Journal:  AJNR Am J Neuroradiol       Date:  2019-12-26       Impact factor: 3.825

2.  Metal artefact reduction in CT imaging of hip prostheses—an evaluation of commercial techniques provided by four vendors.

Authors:  K M Andersson; P Nowik; J Persliden; P Thunberg; E Norrman
Journal:  Br J Radiol       Date:  2015-05-27       Impact factor: 3.039

Review 3.  Imaging spectrum of traumatic urinary bladder and urethral injuries.

Authors:  Sirote Wongwaisayawan; Satheesh Krishna; Adnan Sheikh; Rathachai Kaewlai; Nicola Schieda
Journal:  Abdom Radiol (NY)       Date:  2020-07-28

Review 4.  Imaging update in arthroplasty.

Authors:  Nicholas Ong; Izwan Zailan; Ankit Tandon
Journal:  J Clin Orthop Trauma       Date:  2021-10-21

5.  Addressing CT metal artifacts using photon-counting detectors and one-step spectral CT image reconstruction.

Authors:  Taly Gilat Schmidt; Barbara A Sammut; Rina Foygel Barber; Xiaochuan Pan; Emil Y Sidky
Journal:  Med Phys       Date:  2022-04-05       Impact factor: 4.506

6.  Appearance and Frequency of Gas Interface Artifacts Involving Small Bowel on Rapid-Voltage-Switching Dual-Energy CT Iodine-Density Images.

Authors:  En-Haw Wu; So Yeon Kim; Z Jane Wang; Wei-Chou Chang; Li-Qin Zhao; Benjamin M Yeh
Journal:  AJR Am J Roentgenol       Date:  2016-02       Impact factor: 3.959

7.  Prior Image Constrained Compressed Sensing Metal Artifact Reduction (PICCS-MAR): 2D and 3D Image Quality Improvement with Hip Prostheses at CT Colonography.

Authors:  Peter Bannas; Yinsheng Li; Utaroh Motosugi; Ke Li; Meghan Lubner; Guang-Hong Chen; Perry J Pickhardt
Journal:  Eur Radiol       Date:  2015-10-31       Impact factor: 5.315

Review 8.  ACR Appropriateness Criteria® external beam radiation therapy treatment planning for clinically localized prostate cancer, part I of II.

Authors:  Nicholas G Zaorsky; Timothy N Showalter; Gary A Ezzell; Paul L Nguyen; Dean G Assimos; Anthony V D'Amico; Alexander R Gottschalk; Gary S Gustafson; Sameer R Keole; Stanley L Liauw; Shane Lloyd; Patrick W McLaughlin; Benjamin Movsas; Bradley R Prestidge; Al V Taira; Neha Vapiwala; Brian J Davis
Journal:  Adv Radiat Oncol       Date:  2016-10-20

9.  Comparison and Combination of Dual-Energy- and Iterative-Based Metal Artefact Reduction on Hip Prosthesis and Dental Implants.

Authors:  Malte N Bongers; Christoph Schabel; Christoph Thomas; Rainer Raupach; Mike Notohamiprodjo; Konstantin Nikolaou; Fabian Bamberg
Journal:  PLoS One       Date:  2015-11-24       Impact factor: 3.240

Review 10.  ACR Appropriateness Criteria for external beam radiation therapy treatment planning for clinically localized prostate cancer, part II of II.

Authors:  Nicholas G Zaorsky; Timothy N Showalter; Gary A Ezzell; Paul L Nguyen; Dean G Assimos; Anthony V D'Amico; Alexander R Gottschalk; Gary S Gustafson; Sameer R Keole; Stanley L Liauw; Shane Lloyd; Patrick W McLaughlin; Benjamin Movsas; Bradley R Prestidge; Al V Taira; Neha Vapiwala; Brian J Davis
Journal:  Adv Radiat Oncol       Date:  2017-03-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.