Prior Image Constrained Compressed Sensing Metal Artifact Reduction (PICCS-MAR): 2D and 3D Image Quality Improvement with Hip Prostheses at CT Colonography.

Peter Bannas1,2, Yinsheng Li3, Utaroh Motosugi4,5, Ke Li4,3, Meghan Lubner4, Guang-Hong Chen4,3, Perry J Pickhardt4.   

Abstract

PURPOSE: To assess the effect of the prior-image-constrained-compressed-sensing-based metal-artefact-reduction (PICCS-MAR) algorithm on streak artefact reduction and 2D and 3D-image quality improvement in patients with total hip arthroplasty (THA) undergoing CT colonography (CTC).
MATERIALS AND METHODS: PICCS-MAR was applied to filtered-back-projection (FBP)-reconstructed DICOM CTC-images in 52 patients with THA (unilateral, n = 30; bilateral, n = 22). For FBP and PICCS-MAR series, ROI-measurements of CT-numbers were obtained at predefined levels for fat, muscle, air, and the most severe artefact. Two radiologists independently reviewed 2D and 3D CTC-images and graded artefacts and image quality using a five-point-scale (1 = severe streak/no-diagnostic confidence, 5 = no streak/excellent image-quality, high-confidence). Results were compared using paired and unpaired t-tests and Wilcoxon signed-rank and Mann-Whitney-tests.
RESULTS: Streak artefacts and image quality scores for FBP versus PICCS-MAR 2D-images (median: 1 vs. 3 and 2 vs. 3, respectively) and 3D images (median: 2 vs. 4 and 3 vs. 4, respectively) showed significant improvement after PICCS-MAR (all P < 0.001). PICCS-MAR significantly improved the accuracy of mean CT numbers for fat, muscle and the area with the most severe artefact (all P < 0.001).
CONCLUSIONS: PICCS-MAR substantially reduces streak artefacts related to THA on DICOM images, thereby enhancing visualization of anatomy on 2D and 3D CTC images and increasing diagnostic confidence. KEY POINTS: • PICCS-MAR significantly reduces streak artefacts associated with total hip arthroplasty on 2D and 3D CTC. • PICCS-MAR significantly improves 2D and 3D CTC image quality and diagnostic confidence. • PICCS-MAR can be applied retrospectively to DICOM images from single-kVp CT.

Entities:  

Keywords:  CT; CT colonography; Computed tomography; Metal artefact reduction; Total hip arthroplasty

Mesh:

Substances:

Year:  2015        PMID: 26521266      PMCID: PMC4852162          DOI: 10.1007/s00330-015-4044-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  25 in total

1.  Frequency split metal artifact reduction (FSMAR) in computed tomography.

Authors:  Esther Meyer; Rainer Raupach; Michael Lell; Bernhard Schmidt; Marc Kachelrieß
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  Computed tomographic metal artifact reduction for the detection and quantitation of small features near large metallic implants: a comparison of published methods.

Authors:  Jean Rinkel; William P Dillon; Tobias Funk; Robert Gould; Sven Prevrhal
Journal:  J Comput Assist Tomogr       Date:  2008 Jul-Aug       Impact factor: 1.826

3.  Frequency split metal artefact reduction in pelvic computed tomography.

Authors:  M M Lell; E Meyer; M Schmid; R Raupach; M S May; M Uder; M Kachelriess
Journal:  Eur Radiol       Date:  2013-03-22       Impact factor: 5.315

4.  Metal artifact reduction software used with abdominopelvic dual-energy CT of patients with metal hip prostheses: assessment of image quality and clinical feasibility.

Authors:  Seung Chol Han; Yong Eun Chung; Young Han Lee; Kwan Kyu Park; Myeong Jin Kim; Ki Whang Kim
Journal:  AJR Am J Roentgenol       Date:  2014-10       Impact factor: 3.959

5.  An algorithm for the reduction of metal clip artifacts in CT reconstructions.

Authors:  G H Glover; N J Pelc
Journal:  Med Phys       Date:  1981 Nov-Dec       Impact factor: 4.071

6.  Blackout and other artefacts in computed tomography caused by fillings in teeth.

Authors:  P Svendsen; L Quiding; I Landahl
Journal:  Neuroradiology       Date:  1980       Impact factor: 2.804

7.  Artifacts in CT: recognition and avoidance.

Authors:  Julia F Barrett; Nicholas Keat
Journal:  Radiographics       Date:  2004 Nov-Dec       Impact factor: 5.333

8.  Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation.

Authors:  Fabian Bamberg; Alexander Dierks; Konstantin Nikolaou; Maximilian F Reiser; Christoph R Becker; Thorsten R C Johnson
Journal:  Eur Radiol       Date:  2011-01-20       Impact factor: 5.315

9.  Automated volumetric analysis for comparison of oral sulfate solution (SUPREP) with established cathartic agents at CT colonography.

Authors:  Peter Bannas; Joshua Bakke; James L Patrick; Perry J Pickhardt
Journal:  Abdom Imaging       Date:  2015-01

10.  Metal artefact reduction from dental hardware in carotid CT angiography using iterative reconstructions.

Authors:  Fabian Morsbach; Moritz Wurnig; Daniel M Kunz; Andreas Krauss; Bernhard Schmidt; Spyros S Kollias; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2013-05-19       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.