Comparison of Airtraq optical laryngoscope and Storz video laryngoscope in a cadaver model.

Michael C Wadman1, Travis W Dierks1, Chad E Branecki1, Claudia L Barthold1, Lance H Hoffman1, Lina Lander1, Carol S Lomneth1, Richard A Walker1.   

Abstract

BACKGROUND: Airway management in the emergency department is a critical intervention that requires both standard techniques and rescue techniques to ensure a high rate of success. Recently, video laryngoscope (VL) systems have become increasingly common in many large urban EDs, but these systems may exceed the budgets of smaller rural EDs and EMS services and the Airtraq optical laryngoscope (OL) may provide an effective, low-cost alternative. We hypothesized that laryngeal view and time to endothracheal tube placement for OL and VL intubations would not be significantly different.
METHODS: This was a prospective, crossover trial.
SETTING: University-based emergency medicine residency program procedure laboratory utilizing lightly embalmed cadavers.
SUBJECTS: PGY1-3 emergency medicine residents. The study subjects performed timed endotracheal intubations alternately using the OL and VL. The subjects then rated the Cormack-Lehane laryngeal view for each device. STATISTICAL ANALYSIS: Mean time to intubation and the mean laryngeal view score were calculated with 95% confidence intervals and statistical significance was determined by Student's t test.
RESULTS: Fourteen subjects completed the study. The average laryngeal view achieved with the OL vs. the VL was not significantly different, with Cormack-Lehane grade of 1.14 vs. 1.07, respectively. Time to endotracheal intubation, however, was significantly different (P<0.001) with the average time to intubation for the OL 25.49 seconds (95% CI: 17.95-33.03) and the VL 13.41 seconds (10.27-16.55).
CONCLUSION: The Airtraq OL and the Storz VL yielded similar laryngeal views in the lightly embalmed cadaver model. Time to endotracheal tube placement, however, was less for the VL.

Entities:  

Keywords:  Airtraq optical laryngoscope; Laryngoscope; Video laryngoscope

Year:  2011        PMID: 25215005      PMCID: PMC4129714          DOI: 10.5847/wjem.j.1920-8642.2011.03.003

Source DB:  PubMed          Journal:  World J Emerg Med        ISSN: 1920-8642


  17 in total

1.  Evaluation of an improved scoring system for the grading of direct laryngoscopy.

Authors:  S M Yentis; D J Lee
Journal:  Anaesthesia       Date:  1998-11       Impact factor: 6.955

2.  Predicting difficult intubation in apparently normal patients: a meta-analysis of bedside screening test performance.

Authors:  Toshiya Shiga; Zen'ichiro Wajima; Tetsuo Inoue; Atsuhiro Sakamoto
Journal:  Anesthesiology       Date:  2005-08       Impact factor: 7.892

3.  Comparison of the Glidescope, the McGrath, the Airtraq and the Macintosh laryngoscopes in simulated difficult airways*.

Authors:  G L Savoldelli; E Schiffer; C Abegg; V Baeriswyl; F Clergue; J L Waeber
Journal:  Anaesthesia       Date:  2008-12       Impact factor: 6.955

4.  Learning curves of the Glidescope, the McGrath and the Airtraq laryngoscopes: a manikin study.

Authors:  Georges L Savoldelli; Eduardo Schiffer; Christoph Abegg; Vincent Baeriswyl; François Clergue; Jean-Luc Waeber
Journal:  Eur J Anaesthesiol       Date:  2009-07       Impact factor: 4.330

5.  Tracheal intubation in patients with rigid collar immobilisation of the cervical spine: a comparison of Airtraq and LMA CTrach devices.

Authors:  Z I Arslan; T Yildiz; Z N Baykara; M Solak; K Toker
Journal:  Anaesthesia       Date:  2009-10-22       Impact factor: 6.955

6.  Difficult tracheal intubation in obstetrics.

Authors:  R S Cormack; J Lehane
Journal:  Anaesthesia       Date:  1984-11       Impact factor: 6.955

7.  Improved glottic exposure with the Video Macintosh Laryngoscope in adult emergency department tracheal intubations.

Authors:  Calvin A Brown; Aaron E Bair; Daniel J Pallin; Erik G Laurin; Ron M Walls
Journal:  Ann Emerg Med       Date:  2010-03-03       Impact factor: 5.721

8.  A comparison of the STORZ video laryngoscope and standard direct laryngoscopy for intubation in the Pediatric airway--a randomized clinical trial.

Authors:  Arnim Vlatten; Sylvie Aucoin; Sharon Litz; Brian Macmanus; Chris Soder
Journal:  Paediatr Anaesth       Date:  2009-08-25       Impact factor: 2.556

9.  A comparison of cervical spine movement during laryngoscopy using the Airtraq or Macintosh laryngoscopes.

Authors:  Y Hirabayashi; A Fujita; N Seo; H Sugimoto
Journal:  Anaesthesia       Date:  2008-06       Impact factor: 6.955

10.  Endotracheal intubation in patients with cervical spine immobilization: a comparison of macintosh and airtraq laryngoscopes.

Authors:  Chrisen H Maharaj; Elma Buckley; Brian H Harte; John G Laffey
Journal:  Anesthesiology       Date:  2007-07       Impact factor: 7.892

View more
  1 in total

1.  Video versus direct laryngoscopy on successful first-pass endotracheal intubation in ICU patients.

Authors:  Yong-Xia Gao; Yan-Bo Song; Ze-Juan Gu; Jin-Song Zhang; Xu-Feng Chen; Hao Sun; Zhen Lu
Journal:  World J Emerg Med       Date:  2018
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.