Tracheal intubation in patients with rigid collar immobilisation of the cervical spine: a comparison of Airtraq and LMA CTrach devices.

Z I Arslan1, T Yildiz, Z N Baykara, M Solak, K Toker.   

Abstract

The aim of this study was to evaluate the effectiveness of the Airtraq and CTrach in lean patients with simulated cervical spine injury after application of a rigid cervical collar. Eighty-six consenting adult patients of ASA physical status 1 or 2, who required elective tracheal intubation were included in this study in a randomised manner. Anaesthesia was induced using 1 microg kg(-1) fentanyl, 3 mg kg(-1) propofol and 0.6 mg kg(-1) rocuronium, following which a rigid cervical collar was applied. Comparison was then made between tracheal intubation techniques using either the AirTraq or CTrach device. The mean (SD) time to see the glottis was shorter with the Airtraq than the CTrach (11.9 (6.8) vs 37.6 (16.7)s, respectively; p < 0.001). The mean (SD) time taken for tracheal intubation was also shorter with the Airtraq than the CTrach (25.6 (13.5) and 66.3 (29.3)s, respectively; p < 0.001). There was less mucosal damage in the Airtraq group (p = 0.008). Our findings demonstrate that use of the Airtraq device shortened the tracheal intubation time and reduced the mucosal damage when compared with the CTrach in patients who require cervical spine immobilisation.

Entities:  

Mesh:

Year:  2009        PMID: 19849685     DOI: 10.1111/j.1365-2044.2009.06053.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  15 in total

1.  Respiratory parameters as a surrogate marker for duration of intubation: potential application of automated vital sign collection.

Authors:  Doug Hester; Stuart McGrane; Michael S Higgins
Journal:  J Clin Monit Comput       Date:  2013-04-13       Impact factor: 2.502

2.  Comparison of Airtraq optical laryngoscope and Storz video laryngoscope in a cadaver model.

Authors:  Michael C Wadman; Travis W Dierks; Chad E Branecki; Claudia L Barthold; Lance H Hoffman; Lina Lander; Carol S Lomneth; Richard A Walker
Journal:  World J Emerg Med       Date:  2011

3.  Endotracheal intubation with intubating laryngeal mask airway (ILMA), C-Trach, and Cobra PLA in simulated cervical spine injury patients: a comparative study.

Authors:  Deepak G Mathew; Rashmi Ramachandran; Vimi Rewari; Anjan Trikha
Journal:  J Anesth       Date:  2014-02-20       Impact factor: 2.078

4.  Recent advance in patient monitoring.

Authors:  Tomoki Nishiyama
Journal:  Korean J Anesthesiol       Date:  2010-09-20

5.  Airtraq, LMA CTrach and Macintosh Laryngoscopes in Tracheal Intubation Training: A Randomized Comparative Manikin Study.

Authors:  Ayten Saraçoğlu; Didem Dal; Ömer Baygın; Fevzi Yılmaz Göğüş
Journal:  Turk J Anaesthesiol Reanim       Date:  2016-04-01

6.  Comparison of the glidescope, CMAC, storz DCI with the Macintosh laryngoscope during simulated difficult laryngoscopy: a manikin study.

Authors:  David W Healy; Paul Picton; Michelle Morris; Christopher Turner
Journal:  BMC Anesthesiol       Date:  2012-06-21       Impact factor: 2.217

7.  Use of the Airtraq® device for airway management in the prehospital setting--a retrospective study.

Authors:  Mikael Gellerfors; Agneta Larsson; Christer H Svensén; Dan Gryth
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2014-02-03       Impact factor: 2.953

8.  A systematic review of the role of videolaryngoscopy in successful orotracheal intubation.

Authors:  David W Healy; Oana Maties; David Hovord; Sachin Kheterpal
Journal:  BMC Anesthesiol       Date:  2012-12-14       Impact factor: 2.217

9.  Comparison of tracheal intubation using the Airtraq(®) and Mc Coy laryngoscope in the presence of rigid cervical collar simulating cervical immobilisation for traumatic cervical spine injury.

Authors:  Padmaja Durga; Jasleen Kaur; Syed Younus Ahmed; Geeta Kaniti; Gopinath Ramachandran
Journal:  Indian J Anaesth       Date:  2012-11

10.  Airway management in cervical spine injury.

Authors:  Naola Austin; Vijay Krishnamoorthy; Arman Dagal
Journal:  Int J Crit Illn Inj Sci       Date:  2014-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.