Accutome PachPen handheld ultrasonic pachymeter: intraobserver repeatability and interobserver reproducibility by personnel of different training grades.

Mohammadreza Peyman1, Lai Yong Tai, Keat Ween Khaw, Choung Min Ng, Maung Maung Win, Visvaraja Subrayan.   

Abstract

To assess the intra-observer repeatability and inter-observer reproducibility of central corneal thickness (CCT) measurements of PachPen (Accutome, Inc., Pennsylvania, USA), a hand-held, portable ultrasonic pachymeter when used by an ophthalmic nurse compared to an ophthalmologist. Ophthalmology Clinic, University of Malaya Medical Center In this prospective study, CCT was measured in 184 eyes of 92 healthy subjects, first by a corneal surgeon experienced in ultrasound pachymetry (Observer 1) followed by an ophthalmic nurse new to the procedure (Observer 2). Nine measurements were obtained from each eye by each observer, independently. Measurements were compared between the observers. Coefficients of repeatability and reproducibility were calculated. The Bland-Altman plot was used to assess agreement between observers. Mean age of the study population was 54.3 ± 15.2 years old and consisted of 43.5% male. Mean CCT as measured by Observers 1 and 2 were 528.3 ± 32.9 and 530.7 ± 33.3 µm, respectively. Observer 1 showed higher repeatability of measurements compared to that of Observer 2 (coefficient of repeatability 3.46 vs. 5.55%). The measurements by both observers showed high correlation (0.96) and good agreement (mean difference -2.4 µm; 95% limits of agreement -21.4, 16.7 µm). Coefficient of reproducibility of measurements between observers was 5.08%. Accutome PachPen hand-held ultrasound pachymeters gives excellent intra-observer repeatability and inter-observer reproducibility by personnel of different training grades.

Mesh:

Year:  2014        PMID: 25189684     DOI: 10.1007/s10792-014-9989-6

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  17 in total

1.  Repeatability and reproducibility of corneal thickness measurements by optical coherence tomography.

Authors:  Sarah Muscat; Nicola McKay; Stuart Parks; Ewan Kemp; David Keating
Journal:  Invest Ophthalmol Vis Sci       Date:  2002-06       Impact factor: 4.799

2.  Clinical assessment of the Zeiss IOLMaster.

Authors:  Ingrid Kielhorn; Madhavan S Rajan; Peter M Tesha; Visva Raja Subryan; John A Bell
Journal:  J Cataract Refract Surg       Date:  2003-03       Impact factor: 3.351

3.  Repeatability and reproducibility of the BVI ultrasonic Pachymeter.

Authors:  P Gunvant; D C Broadway; R J Watkins
Journal:  Eye (Lond)       Date:  2003-10       Impact factor: 3.775

4.  Developing and implementing the role of the nurse bronchoscopist.

Authors:  Julie M Martin
Journal:  Prof Nurse       Date:  2004-02

5.  Advancing the role of minor surgery for nurses.

Authors:  Nicola Dunlop
Journal:  Br J Nurs       Date:  2010 Jun 10-23

6.  Reliability coefficients of three corneal pachymeters.

Authors:  N C Wheeler; C M Morantes; R M Kristensen; T H Pettit; D A Lee
Journal:  Am J Ophthalmol       Date:  1992-06-15       Impact factor: 5.258

7.  Comparison of central corneal thickness measured by four different pachymeters.

Authors:  Elliott H Myrowitz; Shiquan Ren; Roy S Chuck
Journal:  Eye Contact Lens       Date:  2007-05       Impact factor: 2.018

8.  Reliability of noncontact pachymetry after laser in situ keratomileusis.

Authors:  Miguel J Maldonado; Alberto López-Miguel; Juan C Nieto; Juan Cano-Parra; Begoña Calvo; Jorge L Alió
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-04-08       Impact factor: 4.799

Review 9.  Assessment of true intraocular pressure: the gap between theory and practical data.

Authors:  Etsuo Chihara
Journal:  Surv Ophthalmol       Date:  2008 May-Jun       Impact factor: 6.048

10.  Accuracy of Goldmann tonometry in clinical practice.

Authors:  S Sudesh; M J Moseley; J R Thompson
Journal:  Acta Ophthalmol (Copenh)       Date:  1993-04
View more
  3 in total

1.  Comparison of ultrasonic pachymetry and Fourier-domain optical coherence tomography for measurement of corneal thickness in dogs with and without corneal disease.

Authors:  A L Hoehn; S M Thomasy; P H Kass; T Horikawa; M Samuel; O R Shull; K A Stewart; C J Murphy
Journal:  Vet J       Date:  2018-10-30       Impact factor: 2.688

2.  Comparison of central corneal thickness measurements using different imaging devices and ultrasound pachymetry.

Authors:  Ertugrul Can; Hilal Eser-Ozturk; Mustafa Duran; Tugba Cetinkaya; Nursen Arıturk
Journal:  Indian J Ophthalmol       Date:  2019-10       Impact factor: 1.848

3.  Comparison of corneal biomechanics after myopic small-incision lenticule extraction compared to LASIK: an ex vivo study.

Authors:  Anastasios John Kanellopoulos
Journal:  Clin Ophthalmol       Date:  2018-01-25
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.