Accuracy of point-of-care blood glucose measurements in critically ill patients in shock.

Carlo Jan Pati-An Garingarao1, Myrna Buenaluz-Sedurante2, Cecilia Alegado Jimeno2.   

Abstract

A widely used method in monitoring glycemic status of ICU patients is point-of-care (POC) monitoring devices. A possible limitation to this method is altered peripheral blood flow in patients in shock, which may result in over/underestimations of their true glycemic status. This study aims to determine the accuracy of blood glucose measurements with a POC meter compared to laboratory methods in critically ill patients in shock. POC blood glucose was measured with a glucose-1-dehydrogenase-based reflectometric meter. The reference method was venous plasma glucose measured by a clinical chemistry analyzer (glucose oxidase-based). Outcomes assessed were concordance to ISO 15197:2003 minimum accuracy criteria for glucose meters, bias in glucose measurements obtained by the 2 methods using Bland-Altman analysis, and clinical accuracy through modified error grid analysis. A total of 186 paired glucose measurements were obtained. ISO 2003 accuracy criteria were met in 95.7% and 79.8% of POC glucose values in the normotensive and hypotensive group, respectively. Mean bias for the normotensive group was -12.4 mg/dL, while mean bias in the hypotensive group was -34.9 mg/dL. POC glucose measurements within the target zone for clinical accuracy were 90.2% and 79.8% for the normotensive and hypotensive group, respectively. POC blood glucose measurements were significantly less accurate in the hypotensive subgroup of ICU patients compared to the normotensive group. We recommend a lower threshold in confirming POC blood glucose with a central laboratory method if clinically incompatible. In light of recently updated accuracy standards, we also recommend alternative methods of glucose monitoring for the ICU population as a whole regardless of blood pressure status.
© 2014 Diabetes Technology Society.

Entities:  

Keywords:  accuracy; blood glucose; critically ill; hypotension; point-of-care glucose meter; shock

Mesh:

Substances:

Year:  2014        PMID: 25172876      PMCID: PMC4455371          DOI: 10.1177/1932296814538608

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  25 in total

Review 1.  Glucose measurement: confounding issues in setting targets for inpatient management.

Authors:  Kathleen Dungan; John Chapman; Susan S Braithwaite; John Buse
Journal:  Diabetes Care       Date:  2007-02       Impact factor: 19.112

2.  Intensive insulin therapy in mixed medical/surgical intensive care units: benefit versus harm.

Authors:  Greet Van den Berghe; Alexander Wilmer; Ilse Milants; Pieter J Wouters; Bernard Bouckaert; Frans Bruyninckx; Roger Bouillon; Miet Schetz
Journal:  Diabetes       Date:  2006-11       Impact factor: 9.461

3.  The conundrum of the Glasgow Coma Scale in intubated patients: a linear regression prediction of the Glasgow verbal score from the Glasgow eye and motor scores.

Authors:  W Meredith; R Rutledge; S M Fakhry; S Emery; S Kromhout-Schiro
Journal:  J Trauma       Date:  1998-05

4.  Glycometabolic state at admission: important risk marker of mortality in conventionally treated patients with diabetes mellitus and acute myocardial infarction: long-term results from the Diabetes and Insulin-Glucose Infusion in Acute Myocardial Infarction (DIGAMI) study.

Authors:  K Malmberg; A Norhammar; H Wedel; L Rydén
Journal:  Circulation       Date:  1999-05-25       Impact factor: 29.690

5.  Reliability of point-of-care testing for glucose measurement in critically ill adults.

Authors:  Salmaan Kanji; Jennifer Buffie; Brian Hutton; Peter S Bunting; Avinder Singh; Kevin McDonald; Dean Fergusson; Lauralyn A McIntyre; Paul C Hebert
Journal:  Crit Care Med       Date:  2005-12       Impact factor: 7.598

6.  Fingerstick glucose determination in shock.

Authors:  S H Atkin; A Dasmahapatra; M A Jaker; M I Chorost; S Reddy
Journal:  Ann Intern Med       Date:  1991-06-15       Impact factor: 25.391

7.  Accuracy of bedside capillary blood glucose measurements in critically ill patients.

Authors:  C Dana Critchell; Vincent Savarese; Amy Callahan; Christine Aboud; Serge Jabbour; Paul Marik
Journal:  Intensive Care Med       Date:  2007-09-01       Impact factor: 17.440

8.  Severe hypoglycemia in critically ill patients: risk factors and outcomes.

Authors:  James S Krinsley; Aarti Grover
Journal:  Crit Care Med       Date:  2007-10       Impact factor: 7.598

9.  Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock: 2008.

Authors:  R Phillip Dellinger; Mitchell M Levy; Jean M Carlet; Julian Bion; Margaret M Parker; Roman Jaeschke; Konrad Reinhart; Derek C Angus; Christian Brun-Buisson; Richard Beale; Thierry Calandra; Jean-Francois Dhainaut; Herwig Gerlach; Maurene Harvey; John J Marini; John Marshall; Marco Ranieri; Graham Ramsay; Jonathan Sevransky; B Taylor Thompson; Sean Townsend; Jeffrey S Vender; Janice L Zimmerman; Jean-Louis Vincent
Journal:  Crit Care Med       Date:  2008-01       Impact factor: 7.598

10.  Comparison of point-of-care and laboratory glucose analysis in critically ill patients.

Authors:  Teresita Lacara; Caroline Domagtoy; Donna Lickliter; Kathy Quattrocchi; Lydia Snipes; Joánne Kuszaj; MaryClare Prasnikar
Journal:  Am J Crit Care       Date:  2007-07       Impact factor: 2.228

View more
  1 in total

1.  Impact of High-Dose Intravenous Vitamin C for Treatment of Sepsis on Point-of-Care Blood Glucose Readings.

Authors:  Anna Peyton Howell; Jenna L Parrett; Daniel R Malcom
Journal:  J Diabetes Sci Technol       Date:  2019-11-25
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.