Clinical utility of inappropriate positron emission tomography myocardial perfusion imaging: test results and cardiovascular events.

David E Winchester1, Ryan J Chauffe, Ryan Meral, Daniel Nguyen, Scott Ryals, Raman Dusaj, Leslee Shaw, Rebecca J Beyth.   

Abstract

BACKGROUND: Appropriate use criteria for myocardial perfusion imaging (MPI) were developed to categorize scenarios where MPI might be beneficial (appropriate) or not (inappropriate). Few investigations have evaluated the clinical utility of this categorization strategy, particularly with positron emission tomography (PET) MPI. METHODS AND
RESULTS: We conducted this retrospective cohort investigation in a Veterans Affairs (VA) medical center, on predominantly male subjects who underwent PET-MPI. We correlated appropriateness to test result and cardiovascular events. Of 521 subjects, 414 (79.5%) were appropriate, 54 (10.4%) were uncertain, and 53 (10.2%) were inappropriate. PET-MPI was abnormal more often when appropriate or uncertain (28% and 34.6%, respectively, vs 7.7% for inappropriate, P = .003). Among abnormal inappropriate tests, none detected occult ischemia. By Cox regression, summed difference score ≥5 (HR 5.06, 95% CI 2.72-9.44) and an abnormal test result (HR 4.48, 95% CI 2.19-9.14) were associated with higher likelihood of catheterization. Log-rank analysis demonstrated similar likelihood of catheterization when comparing abnormal vs normal test result (P < .0001) and between appropriate, uncertain, and inappropriate tests (P = .024).
CONCLUSIONS: Inappropriate PET-MPI was rarely abnormal, associated with low catheterization rates, and failed to detect occult ischemia for any subjects. The clinical utility of inappropriate PET-MPI is negligible.

Entities:  

Mesh:

Year:  2014        PMID: 25084975     DOI: 10.1007/s12350-014-9925-1

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  15 in total

Review 1.  Prognosis in the era of comparative effectiveness research: where is nuclear cardiology now and where should it be?

Authors:  Leslee J Shaw; Fadi G Hage; Daniel S Berman; Rory Hachamovitch; Ami Iskandrian
Journal:  J Nucl Cardiol       Date:  2012-10       Impact factor: 5.952

2.  Impact of appropriate use on the prognostic value of single-photon emission computed tomography myocardial perfusion imaging.

Authors:  Rami Doukky; Kathleen Hayes; Nathan Frogge; Gautam Balakrishnan; Venkata Satish Dontaraju; Maria O Rangel; Yasmeen Golzar; Enrique Garcia-Sayan; Robert C Hendel
Journal:  Circulation       Date:  2013-09-10       Impact factor: 29.690

Review 3.  ACCF/ASNC appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI): a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group and the American Society of Nuclear Cardiology endorsed by the American Heart Association.

Authors:  Ralph G Brindis; Pamela S Douglas; Robert C Hendel; Eric D Peterson; Michael J Wolk; Joseph M Allen; Manesh R Patel; Ira E Raskin; Robert C Hendel; Timothy M Bateman; Manuel D Cerqueira; Raymond J Gibbons; Linda D Gillam; John A Gillespie; Robert C Hendel; Ami E Iskandrian; Scott D Jerome; Harlan M Krumholz; Joseph V Messer; John A Spertus; Stephen A Stowers
Journal:  J Am Coll Cardiol       Date:  2005-10-18       Impact factor: 24.094

4.  Correlation between clinical outcomes and appropriateness grading for referral to myocardial perfusion imaging for preoperative evaluation prior to non-cardiac surgery.

Authors:  Angela S Koh; Jennifer L S Flores; Felix Y J Keng; Ru San Tan; Terrance S J Chua
Journal:  J Nucl Cardiol       Date:  2012-04       Impact factor: 5.952

5.  The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies.

Authors:  Erik von Elm; Douglas G Altman; Matthias Egger; Stuart J Pocock; Peter C Gøtzsche; Jan P Vandenbroucke
Journal:  Ann Intern Med       Date:  2007-10-16       Impact factor: 25.391

6.  Appropriate use of myocardial perfusion imaging in a veteran population: profit motives and professional liability concerns.

Authors:  David E Winchester; Ryan Meral; Scott Ryals; Rebecca J Beyth; Leslee J Shaw
Journal:  JAMA Intern Med       Date:  2013-07-22       Impact factor: 21.873

7.  The overuse of diagnostic imaging and the Choosing Wisely initiative.

Authors:  Vijay M Rao; David C Levin
Journal:  Ann Intern Med       Date:  2012-10-16       Impact factor: 25.391

8.  The use of a learning community and online evaluation of utilization for SPECT myocardial perfusion imaging.

Authors:  Samira Saifi; Allen J Taylor; Joseph Allen; Robert Hendel
Journal:  JACC Cardiovasc Imaging       Date:  2013-05-01

9.  Appropriate test selection for single-photon emission computed tomography imaging: association with clinical risk, posttest management, and outcomes.

Authors:  Nael Aldweib; Kazuaki Negishi; Sinziana Seicean; Wael A Jaber; Rory Hachamovitch; Manuel Cerqueira; Thomas H Marwick
Journal:  Am Heart J       Date:  2013-07-16       Impact factor: 4.749

10.  Yield and diagnostic value of stress myocardial perfusion imaging in patients without known coronary artery disease presenting with syncope.

Authors:  Wael A AlJaroudi; M Chadi Alraies; Oussama Wazni; Manuel D Cerqueira; Wael A Jaber
Journal:  Circ Cardiovasc Imaging       Date:  2013-02-15       Impact factor: 7.792

View more
  5 in total

Review 1.  Review of cardiovascular imaging in the journal of nuclear cardiology in 2015. Part 1 of 2: Plaque imaging, positron emission tomography, computed tomography, and magnetic resonance.

Authors:  Wael A AlJaroudi; Fadi G Hage
Journal:  J Nucl Cardiol       Date:  2015-11-05       Impact factor: 5.952

2.  Metrics of quality care in veterans: correlation between primary-care performance measures and inappropriate myocardial perfusion imaging.

Authors:  David E Winchester; Andrew Kitchen; John C Brandt; Raman S Dusaj; Salim S Virani; Steven M Bradley; Leslee J Shaw; Rebecca J Beyth
Journal:  Clin Cardiol       Date:  2015-04-13       Impact factor: 2.882

3.  The value and appropriateness of positron emission tomography: an evolving tale.

Authors:  Robert C Hendel
Journal:  J Nucl Cardiol       Date:  2014-08-23       Impact factor: 5.952

Review 4.  Outcomes after inappropriate nuclear myocardial perfusion imaging: A meta-analysis.

Authors:  Islam Y Elgendy; Ahmed Mahmoud; Jonathan J Shuster; Rami Doukky; David E Winchester
Journal:  J Nucl Cardiol       Date:  2015-08-08       Impact factor: 5.952

5.  Downstream clinical consequences of stress cardiovascular magnetic resonance based on appropriate use criteria.

Authors:  Sloane McGraw; Omer Mirza; Michael A Bauml; Vibhav S Rangarajan; Afshin Farzaneh-Far
Journal:  J Cardiovasc Magn Reson       Date:  2015-05-15       Impact factor: 5.364

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.