Literature DB >> 24923689

Does knee stability in the coronal plane in extension affect function and outcome after total knee arthroplasty?

Hiroyuki Nakahara1, Ken Okazaki, Satoshi Hamai, Shigetoshi Okamoto, Umito Kuwashima, Hidehiko Higaki, Yukihide Iwamoto.   

Abstract

PURPOSE: The aim of the present study was to clarify whether varus-valgus laxities under static stress in extension, femoral condylar lift-off during walking, and patient-reported outcomes after total knee arthroplasty (TKA) were correlated with each other.
METHODS: Ninety-four knees, which had undergone posterior-stabilized TKA, were analysed. The varus-valgus laxity during knee extension was measured using a stress radiograph. New Knee Society Score (KSS) questionnaires were mailed to all patients. Correlations between the values of stress radiographs and KSS were analysed. Additionally, continuous radiological images were taken of 15 patients while each walked on a treadmill to determine condylar lift-off from the tibial tray using a 3D-to-2D image-to-model registration technique. Correlations between the amount of lift-off and either the stress radiograph or the KSS were also analyzed.
RESULTS: The mean angle measured was 5.9 ± 2.7° with varus stress and 5.0 ± 1.6° with valgus stress. The difference between them was 0.9 ± 2.8°. Varus-valgus laxities, or the differences between them, did not show any statistically significant correlation with either component of the KSS (p > 0.05). The average amount of femoral condylar lift-off during walking was 1.4 ± 0.8 mm (medial side) and 1.3 ± 0.6 mm (lateral side). The amount of lift-off did not correlate with either varus-valgus laxities or the KSS (p > 0.05).
CONCLUSIONS: No correlations were found among varus-valgus laxities under static stress in extension, femoral condylar lift-off during walking, or patient-reported outcomes after well-aligned TKA. This study suggests that small variations in coronal laxities do not influence lift-off during walking and the patient-reported outcomes. LEVEL OF EVIDENCE: IV.

Entities:  

Mesh:

Year:  2014        PMID: 24923689     DOI: 10.1007/s00167-014-3122-2

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  26 in total

1.  In vivo determination of condylar lift-off and screw-home in a mobile-bearing total knee arthroplasty.

Authors:  J B Stiehl; D A Dennis; R D Komistek; H S Crane
Journal:  J Arthroplasty       Date:  1999-04       Impact factor: 4.757

2.  Correlation between condylar lift-off and femoral component alignment.

Authors:  John N Insall; Giles R Scuderi; Richard D Komistek; Kevin Math; Douglas A Dennis; Dylan T Anderson
Journal:  Clin Orthop Relat Res       Date:  2002-10       Impact factor: 4.176

3.  In vivo laxity of low contact stress mobile-bearing prostheses.

Authors:  Yoshikazu Matsuda; Yoshinori Ishii
Journal:  Clin Orthop Relat Res       Date:  2004-02       Impact factor: 4.176

4.  Development of a new Knee Society scoring system.

Authors:  Philip C Noble; Giles R Scuderi; Adam C Brekke; Alla Sikorskii; James B Benjamin; Jess H Lonner; Priya Chadha; Daniel A Daylamani; W Norman Scott; Robert B Bourne
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

5.  Tibial component failure mechanisms in total knee arthroplasty.

Authors:  Michael E Berend; Merrill A Ritter; John B Meding; Philip M Faris; E Michael Keating; Ryan Redelman; Gregory W Faris; Kenneth E Davis
Journal:  Clin Orthop Relat Res       Date:  2004-11       Impact factor: 4.176

6.  Effect of knee laxity on in vivo kinematics of meniscal-bearing knee prostheses.

Authors:  Yoshinori Ishii; Hideo Noguchi; Yoshikazu Matsuda; Mitsuhiro Takeda; Scott A Walker; Richard D Komistek
Journal:  Knee       Date:  2007-06-12       Impact factor: 2.199

7.  Laxity and function in knee replacements. A comparative study of three prosthetic designs.

Authors:  P J Warren; T K Olanlokun; A G Cobb; P S Walker; B F Iverson
Journal:  Clin Orthop Relat Res       Date:  1994-08       Impact factor: 4.176

8.  Postoperative alignment and ROM affect patient satisfaction after TKA.

Authors:  Shuichi Matsuda; Shinya Kawahara; Ken Okazaki; Yasutaka Tashiro; Yukihide Iwamoto
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

9.  Patient satisfaction after total knee arthroplasty is affected by their general physical well-being.

Authors:  N D Clement; R Burnett
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-05-14       Impact factor: 4.342

10.  Influence of collateral ligament laxity on patient satisfaction after total knee arthroplasty: a comparative bilateral study.

Authors:  M S Kuster; B Bitschnau; T Votruba
Journal:  Arch Orthop Trauma Surg       Date:  2004-05-20       Impact factor: 3.067

View more
  11 in total

1.  No influence of femoral component rotation by the lateral femoral posterior condylar cartilage remnant technique on clinical outcomes in navigation-assisted TKA.

Authors:  Seong Hwan Kim; Yong-Beom Park; Dae Woong Ham; Jae-Sung Lee; Min-Ku Song; Han-Jun Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-08-02       Impact factor: 4.342

2.  No condylar lift-off occurs because of excessive lateral soft tissue laxity in neutrally aligned total knee arthroplasty: a computer simulation study.

Authors:  Shinichi Kuriyama; Masahiro Ishikawa; Shinichiro Nakamura; Moritoshi Furu; Hiromu Ito; Shuichi Matsuda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-07-04       Impact factor: 4.342

3.  Varus femoral and tibial coronal alignments result in different kinematics and kinetics after total knee arthroplasty.

Authors:  Mutsumi Watanabe; Shinichi Kuriyama; Shinichiro Nakamura; Yoshihisa Tanaka; Kohei Nishitani; Moritoshi Furu; Hiromu Ito; Shuichi Matsuda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-05-08       Impact factor: 4.342

4.  Does post-operative knee awareness differ between knees in bilateral simultaneous total knee arthroplasty? Predictors of high or low knee awareness.

Authors:  Katrine Abildgaard Nielsen; Morten Grove Thomsen; Roshan Latifi; Thomas Kallemose; Henrik Husted; Anders Troelsen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-02-09       Impact factor: 4.342

5.  Coronal and sagittal laxity affects clinical outcomes in posterior-stabilized total knee arthroplasty: assessment of well-functioning knees.

Authors:  Toshifumi Watanabe; Hideyuki Koga; Hiroki Katagiri; Koji Otabe; Yusuke Nakagawa; Takeshi Muneta; Ichiro Sekiya; Tetsuya Jinno
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-04-12       Impact factor: 4.342

6.  Impact of intra-operative predictive ligament balance on post-operative balance and patient outcome in TKA: a prospective multicenter study.

Authors:  John M Keggi; Edgar A Wakelin; Jan A Koenig; Jeffrey M Lawrence; Amber L Randall; Corey E Ponder; Jeffrey H DeClaire; Sami Shalhoub; Stephen Lyman; Christopher Plaskos
Journal:  Arch Orthop Trauma Surg       Date:  2021-07-13       Impact factor: 3.067

7.  Do CAS measurements correlate with EOS 3D alignment measurements in primary TKA?

Authors:  Marrigje F Meijer; Alexander L Boerboom; Sjoerd K Bulstra; Inge H F Reininga; Martin Stevens
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-02-25       Impact factor: 4.342

8.  The impact of generalized joint laxity on clinical outcomes of total knee arthroplasty.

Authors:  Sae Kwang Kwon; Hyuck Min Kwon; Youngho Kong; Kwan Kyu Park
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-03-06       Impact factor: 4.342

9.  Component Alignment in Simultaneous Bilateral versus Unilateral Total Knee Arthroplasty.

Authors:  Irfan Qadir; Bahar Shah; Muhammad Waqas; Umair Ahmad; Shahzad Javed; Amer Aziz
Journal:  Knee Surg Relat Res       Date:  2019-03-01

10.  Relationship between outcome scores and knee laxity following total knee arthroplasty: a systematic review.

Authors:  Andreas Kappel; Mogens Laursen; Poul T Nielsen; Anders Odgaard
Journal:  Acta Orthop       Date:  2018-12-20       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.