Literature DB >> 24910125

Total hip prosthesis CT with single-energy projection-based metallic artifact reduction: impact on the visualization of specific periprosthetic soft tissue structures.

Pedro Augusto Gondim Teixeira1, Jean-Baptiste Meyer, Cedric Baumann, Ariane Raymond, François Sirveaux, Henry Coudane, Alain Blum.   

Abstract

OBJECTIVES: To compare the image quality of CT with iterative reconstruction alone and in association with projection-based single-energy metal artifact reduction (SEMAR) for the visualization of specific periarticular soft tissue structures in patients with hip prostheses.
METHODS: CT studies from 48 consecutive patients with a hip prosthesis (24 unilateral and 24 bilateral) were retrospectively reconstructed using two different methods: iterative reconstruction (IR) alone and IR associated with SEMAR. The influence of metallic artifacts on the identification of various periarticular structures was evaluated subjectively by two readers. The image quality was compared in patients with unilateral and bilateral prostheses.
RESULTS: Visualization of periprosthetic soft tissue was significantly improved by the SEMAR algorithm (p < 0.0001). When SEMAR was associated with IR, the gluteus minimus and medius tendons, obturator internus muscle, prostate/uterus and bladder could be seen with medium or high confidence. There were no significant differences in image quality between patients with unilateral or bilateral prosthesis when SEMAR was used (p > 0.2). This algorithm increased the detection of periarticular masses by 30%.
CONCLUSION: SEMAR significantly improves the image quality of periarticular soft-tissue structures in patients with hip prostheses.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24910125     DOI: 10.1007/s00256-014-1923-5

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  23 in total

1.  CT metal artifact reduction method correcting for beam hardening and missing projections.

Authors:  Joost M Verburg; Joao Seco
Journal:  Phys Med Biol       Date:  2012-04-18       Impact factor: 3.609

Review 2.  Groin pain after replacement of the hip: aetiology, evaluation and treatment.

Authors:  R A Henderson; P F Lachiewicz
Journal:  J Bone Joint Surg Br       Date:  2012-02

3.  Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software.

Authors:  Young Han Lee; Kwan Kyu Park; Ho-Taek Song; Sungjun Kim; Jin-Suck Suh
Journal:  Eur Radiol       Date:  2012-02-04       Impact factor: 5.315

Review 4.  CT and MRI of hip arthroplasty.

Authors:  J G Cahir; A P Toms; T J Marshall; J Wimhurst; J Nolan
Journal:  Clin Radiol       Date:  2007-08-30       Impact factor: 2.350

5.  Measuring femoral lesions despite CT metal artefacts: a cadaveric study.

Authors:  Daniel F Malan; Charl P Botha; Gert Kraaij; Raoul M S Joemai; Huub J L van der Heide; Rob G H H Nelissen; Edward R Valstar
Journal:  Skeletal Radiol       Date:  2011-07-06       Impact factor: 2.199

Review 6.  Genitourinary applications of dual-energy CT.

Authors:  Terri J Vrtiska; Naoki Takahashi; Joel G Fletcher; Robert P Hartman; Lifeng Yu; Akira Kawashima
Journal:  AJR Am J Roentgenol       Date:  2010-06       Impact factor: 3.959

7.  CT image quality improvement using Adaptive Iterative Dose Reduction with wide-volume acquisition on 320-detector CT.

Authors:  Alban Gervaise; Benoît Osemont; Sophie Lecocq; Alain Noel; Emilien Micard; Jacques Felblinger; Alain Blum
Journal:  Eur Radiol       Date:  2011-09-17       Impact factor: 5.315

Review 8.  Common sonographic findings in the painful hip after hip arthroplasty.

Authors:  Suzanne S Long; David Surrey; Levon N Nazarian
Journal:  J Ultrasound Med       Date:  2012-02       Impact factor: 2.153

9.  Spectral CT with metal artifacts reduction software for improvement of tumor visibility in the vicinity of gold fiducial markers.

Authors:  Olga R Brook; Sofia Gourtsoyianni; Alexander Brook; Anand Mahadevan; Carol Wilcox; Vassilios Raptopoulos
Journal:  Radiology       Date:  2012-03-13       Impact factor: 11.105

10.  Metal artifact reduction from reformatted projections for hip prostheses in multislice helical computed tomography: techniques and initial clinical results.

Authors:  Lifeng Yu; Hua Li; Jan Mueller; James M Kofler; Xin Liu; Andrew N Primak; Joel G Fletcher; Luis S Guimaraes; Thanila Macedo; Cynthia H McCollough
Journal:  Invest Radiol       Date:  2009-11       Impact factor: 6.016

View more
  20 in total

1.  Reduction of metallic coil artefacts in computed tomography body imaging: effects of a new single-energy metal artefact reduction algorithm.

Authors:  Masafumi Kidoh; Daisuke Utsunomiya; Osamu Ikeda; Yoshitaka Tamura; Seitaro Oda; Yoshinori Funama; Hideaki Yuki; Takeshi Nakaura; Takayuki Kawano; Toshinori Hirai; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2015-08-14       Impact factor: 5.315

2.  Development and first validation of a simplified CT-based classification system of soft tissue changes in large-head metal-on-metal total hip replacement: intra- and interrater reliability and association with revision rates in a uniform cohort of 664 arthroplasties.

Authors:  Martijn F Boomsma; Mireille A Edens; Christiaan P Van Lingen; Niek Warringa; Harmen B Ettema; Cees C P M Verheyen; Mario Maas
Journal:  Skeletal Radiol       Date:  2015-05-06       Impact factor: 2.199

3.  Improved image quality in abdominal CT in patients who underwent treatment for hepatocellular carcinoma with small metal implants using a raw data-based metal artifact reduction algorithm.

Authors:  Keitaro Sofue; Takeshi Yoshikawa; Yoshiharu Ohno; Noriyuki Negi; Hiroyasu Inokawa; Naoki Sugihara; Kazuro Sugimura
Journal:  Eur Radiol       Date:  2016-12-02       Impact factor: 5.315

4.  Single-energy metal artifact reduction for helical computed tomography of the pelvis in patients with metal hip prostheses.

Authors:  Koichiro Yasaka; Eriko Maeda; Shouhei Hanaoka; Masaki Katsura; Jiro Sato; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2016-07-11       Impact factor: 2.374

5.  Comparison of radiographs, tomosynthesis and CT with metal artifact reduction for the detection of hip prosthetic loosening.

Authors:  Romain Gillet; Pedro Teixeira; Chloé Bonarelli; Henry Coudane; François Sirveaux; Mathias Louis; Alain Blum
Journal:  Eur Radiol       Date:  2018-09-07       Impact factor: 5.315

6.  Coronary CT angiography in patients with implanted cardiac devices: initial experience with the metal artefact reduction technique.

Authors:  Fuminari Tatsugami; Toru Higaki; Hiroaki Sakane; Wataru Fukumoto; Makoto Iida; Yasutaka Baba; Chikako Fujioka; Yasuki Kihara; So Tsushima; Kazuo Awai
Journal:  Br J Radiol       Date:  2016-09-29       Impact factor: 3.039

7.  Utility of second-generation single-energy metal artifact reduction in helical lung computed tomography for patients with pulmonary arteriovenous malformation after coil embolization.

Authors:  Yudai Asano; Akihiro Tada; Takayoshi Shinya; Yoshihisa Masaoka; Toshihiro Iguchi; Shuhei Sato; Susumu Kanazawa
Journal:  Jpn J Radiol       Date:  2018-02-10       Impact factor: 2.374

8.  Single-energy metal artifact reduction technique for reducing metallic coil artifacts on post-interventional cerebral CT and CT angiography.

Authors:  Masaki Katsura; Jiro Sato; Masaaki Akahane; Taku Tajima; Toshihiro Furuta; Harushi Mori; Osamu Abe
Journal:  Neuroradiology       Date:  2018-08-24       Impact factor: 2.804

9.  Added value of a single-energy projection-based metal-artifact reduction algorithm for the computed tomography evaluation of oral cavity cancers.

Authors:  Kenichiro Hirata; Daisuke Utsunomiya; Seitaro Oda; Masafumi Kidoh; Yoshinori Funama; Hideaki Yuki; Morikatsu Yoshida; Yasuyuki Yamashita
Journal:  Jpn J Radiol       Date:  2015-08-19       Impact factor: 2.374

10.  Evaluation of the quality of CT images acquired with the single energy metal artifact reduction (SEMAR) algorithm in patients with hip and dental prostheses and aneurysm embolization coils.

Authors:  Akinaga Sonoda; Norihisa Nitta; Noritoshi Ushio; Yukihiro Nagatani; Noriaki Okumura; Hideji Otani; Kiyoshi Murata
Journal:  Jpn J Radiol       Date:  2015-09-24       Impact factor: 2.374

View more