Literature DB >> 27913913

Improved image quality in abdominal CT in patients who underwent treatment for hepatocellular carcinoma with small metal implants using a raw data-based metal artifact reduction algorithm.

Keitaro Sofue1, Takeshi Yoshikawa2,3, Yoshiharu Ohno2,3, Noriyuki Negi4, Hiroyasu Inokawa5, Naoki Sugihara5, Kazuro Sugimura6.   

Abstract

OBJECTIVES: To determine the value of a raw data-based metal artifact reduction (SEMAR) algorithm for image quality improvement in abdominal CT for patients with small metal implants.
METHODS: Fifty-eight patients with small metal implants (3-15 mm in size) who underwent treatment for hepatocellular carcinoma were imaged with CT. CT data were reconstructed by filtered back projection with and without SEMAR algorithm in axial and coronal planes. To evaluate metal artefact reduction, mean CT number (HU and SD) and artefact index (AI) values within the liver were calculated. Two readers independently evaluated image quality of the liver and pancreas and visualization of vasculature using a 5-point visual score. HU and AI values and image quality on images with and without SEMAR were compared using the paired Student's t-test and Wilcoxon signed rank test. Interobserver agreement was evaluated using linear-weighted κ test.
RESULTS: Mean HU and AI on images with SEMAR was significantly lower than those without SEMAR (P < 0.0001). Liver and pancreas image qualities and visualizations of vasculature were significantly improved on CT with SEMAR (P < 0.0001) with substantial or almost perfect agreement (0.62 ≤ κ ≤ 0.83).
CONCLUSIONS: SEMAR can improve image quality in abdominal CT in patients with small metal implants by reducing metallic artefacts. KEY POINTS: • SEMAR algorithm significantly reduces metallic artefacts from small implants in abdominal CT. • SEMAR can improve image quality of the liver in dynamic CECT. • Confidence visualization of hepatic vascular anatomies can also be improved by SEMAR.

Entities:  

Keywords:  Abdominal; Computed tomography; Hepatocellular carcinoma; Liver; Metal artefact reduction

Mesh:

Substances:

Year:  2016        PMID: 27913913     DOI: 10.1007/s00330-016-4660-4

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  30 in total

1.  Benefits of routine use of coronal and sagittal reformations in multi-slice CT examination of the abdomen and pelvis.

Authors:  K Sandrasegaran; J Rydberg; M Tann; D R Hawes; K K Kopecky; D D Maglinte
Journal:  Clin Radiol       Date:  2007-04       Impact factor: 2.350

2.  Metal artifacts reduction using monochromatic images from spectral CT: evaluation of pedicle screws in patients with scoliosis.

Authors:  Yang Wang; Bangping Qian; Baoxin Li; Guochu Qin; Zhengyang Zhou; Yong Qiu; Xizhao Sun; Bin Zhu
Journal:  Eur J Radiol       Date:  2013-03-19       Impact factor: 3.528

3.  Spectral CT with metal artifacts reduction software for improvement of tumor visibility in the vicinity of gold fiducial markers.

Authors:  Olga R Brook; Sofia Gourtsoyianni; Alexander Brook; Anand Mahadevan; Carol Wilcox; Vassilios Raptopoulos
Journal:  Radiology       Date:  2012-03-13       Impact factor: 11.105

4.  Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation.

Authors:  Fabian Bamberg; Alexander Dierks; Konstantin Nikolaou; Maximilian F Reiser; Christoph R Becker; Thorsten R C Johnson
Journal:  Eur Radiol       Date:  2011-01-20       Impact factor: 5.315

5.  Evaluation of hypervascular hepatocellular carcinoma in cirrhotic liver: comparison of different concentrations of contrast material with multi-detector row helical CT--a prospective randomized study.

Authors:  Keitaro Sofue; Masakatsu Tsurusaki; Ryota Kawasaki; Masahiko Fujii; Kazuro Sugimura
Journal:  Eur J Radiol       Date:  2010-11-09       Impact factor: 3.528

6.  Multi-detector row CT of relevant vascular anatomy of the surgical plane in split-liver transplantation.

Authors:  Michael J Guiney; Jonathan B Kruskal; Jacob Sosna; Douglas W Hanto; S Nahum Goldberg; Vassilios Raptopoulos
Journal:  Radiology       Date:  2003-11       Impact factor: 11.105

7.  Yttrium-90 microsphere radioembolization for the treatment of liver malignancies: a structured meta-analysis.

Authors:  M A D Vente; M Wondergem; I van der Tweel; M A A J van den Bosch; B A Zonnenberg; M G E H Lam; A D van Het Schip; J F W Nijsen
Journal:  Eur Radiol       Date:  2008-11-07       Impact factor: 5.315

8.  Detection of hepatocellular carcinoma in patients with cirrhosis: added value of coronal reformations from isotropic voxels with 64-MDCT.

Authors:  Daniele Marin; Carlo Catalano; Gianmaria De Filippis; Michele Di Martino; Antonino Guerrisi; Massimo Rossi; Roberto Passariello
Journal:  AJR Am J Roentgenol       Date:  2009-01       Impact factor: 3.959

9.  Radiation dermatitis following radioembolization for hepatocellular carcinoma: a case for prophylactic embolization of a patent falciform artery.

Authors:  Quor M Leong; Hee K Lai; Richard G H Lo; Terence K B Teo; Anthony Goh; Pierce K H Chow
Journal:  J Vasc Interv Radiol       Date:  2009-05-05       Impact factor: 3.464

10.  Metal artefact reduction from dental hardware in carotid CT angiography using iterative reconstructions.

Authors:  Fabian Morsbach; Moritz Wurnig; Daniel M Kunz; Andreas Krauss; Bernhard Schmidt; Spyros S Kollias; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2013-05-19       Impact factor: 5.315

View more
  4 in total

1.  Prototype metal artefact reduction algorithm in flat panel computed tomography - evaluation in patients undergoing transarterial hepatic radioembolisation.

Authors:  Qeumars Mustafa Hamie; Adrian Raoul Kobe; Leif Mietzsch; Michael Manhart; Gilbert Dominique Puippe; Thomas Pfammatter; Roman Guggenberger
Journal:  Eur Radiol       Date:  2017-07-14       Impact factor: 5.315

2.  Utility of second-generation single-energy metal artifact reduction in helical lung computed tomography for patients with pulmonary arteriovenous malformation after coil embolization.

Authors:  Yudai Asano; Akihiro Tada; Takayoshi Shinya; Yoshihisa Masaoka; Toshihiro Iguchi; Shuhei Sato; Susumu Kanazawa
Journal:  Jpn J Radiol       Date:  2018-02-10       Impact factor: 2.374

3.  Single-energy metal artifact reduction technique for reducing metallic coil artifacts on post-interventional cerebral CT and CT angiography.

Authors:  Masaki Katsura; Jiro Sato; Masaaki Akahane; Taku Tajima; Toshihiro Furuta; Harushi Mori; Osamu Abe
Journal:  Neuroradiology       Date:  2018-08-24       Impact factor: 2.804

4.  Evaluation of CT Angiography Image Quality Acquired with Single-Energy Metal Artifact Reduction (SEMAR) Algorithm in Patients After Complex Endovascular Aortic Repair.

Authors:  M A A D Ragusi; R W van der Meer; R M S Joemai; J van Schaik; C S P van Rijswijk
Journal:  Cardiovasc Intervent Radiol       Date:  2017-10-30       Impact factor: 2.740

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.