Literature DB >> 25943898

Development and first validation of a simplified CT-based classification system of soft tissue changes in large-head metal-on-metal total hip replacement: intra- and interrater reliability and association with revision rates in a uniform cohort of 664 arthroplasties.

Martijn F Boomsma1, Mireille A Edens, Christiaan P Van Lingen, Niek Warringa, Harmen B Ettema, Cees C P M Verheyen, Mario Maas.   

Abstract

OBJECTIVE: After implantation of a metal-on-metal total hip arthroplasty (MoM THA), a large incidence of pseudotumor formation has been described recently. Several centers have invited patients for follow-up in order to screen for pseudotumor formation. The spectrum of abnormalities found by CT in MoM THA patients can be unfamiliar to radiologists and orthopedic surgeons. Previously, a CT five-point grading scale has been published. In this paper, a simplification into a three-point classification system gives insight in the morphological distinction of abnormalities of the postoperative hip capsule in MoM implants in relation to the decision for revision. The reliability of this simplified classification regarding intra- and interrater reliability and its association with revision rate is investigated and discussed.
MATERIALS AND METHODS: All patients who underwent MoM THA in our hospital were invited for screening. Various clinical measures and CT scan were obtained in a cross-sectional fashion. A decision on revision surgery was made shortly after screening. CT scans were read in 582 patients, of which 82 patients were treated bilaterally. CT scans were independently single read by two board-certified radiologists and classified into categories I-V. In a second meeting, consensus was obtained. Categories were subsequently rubricated in class A (categories I and II), B (category III), and C (categories IV and V). Intra- and inter-radiologist agreement on MoM pathology was assessed by means of the weighted Cohen's kappa. Categorical data were presented as n (%), and tested by means of Fisher's exact test. Continuous data were presented as median (min-max) and tested by means of Mann-Whitney U test (two group comparison) or Kruskal-Wallis test (three group comparison). Logistic regression analysis was performed in order to study independence of CT class for association with revision surgery. Univariate statistically significant variables were entered in a multiple model. All statistical analysis was performed two-tailed using alpha 5% as the significance level.
RESULTS: In total, 664 scores from 664 MoM hips obtained by two observers were available for analyses. Interobserver reliability for the non-simplified version (I-V) was κw = 0.71 (95% CI: 0.62-0.79), which indicates good agreement between the two musculoskeletal radiologists. Intra- and interobserver reliability for the simplified version (A-C) were respectively κw 0.78 (95% CI: 0.68-0.87), and κw = 0.71 (95% CI: 0.65-0.76). This indicates good agreement within and between the two observers. The simplified A-C version is significantly associated with revision exclusively due to MoM pathology, in both patients with unilateral MoM THA (p < 0.001) and patients with bilateral MoM THA (p < 0.044). The simplified A-C version is associated with several clinical measures. In patients with unilateral MoM THA, with or without contralateral THA, in situ time (p < 0.008), cobalt and chromium (p < 0.001) were statistically significant. In patients with bilateral MoM, cobalt (p < 0.001) and chromium (p < 0.027) were statistically significant. Revision is significantly associated with cup size (p < 0.001), anteversion of the cup (p < 0.004), serum ion levels of cobalt and chromium (p < 0.001) and the adapted classification system (p < 0.001). In univariate logistic regression analysis on revision, cup, anteversion of the cup, cobalt-chromium ion serum levels, and the simplified (A-C) CT category system were statistically significant. The simplified (A-C) CT category system was an independent associate of revision, in several multiple logistic regression models.
CONCLUSIONS: The presented simplified CT grading system (A-C) in its first clinical validation on 48- and 64-multislice systems is reliable, showing good intra- and interrater reliability and is independently associated with revision surgery.

Entities:  

Mesh:

Year:  2015        PMID: 25943898     DOI: 10.1007/s00256-015-2146-0

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  30 in total

1.  Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software.

Authors:  Young Han Lee; Kwan Kyu Park; Ho-Taek Song; Sungjun Kim; Jin-Suck Suh
Journal:  Eur Radiol       Date:  2012-02-04       Impact factor: 5.315

Review 2.  Metal-on-metal vs conventional total hip arthroplasty: a systematic review and meta-analysis of randomized controlled trials.

Authors:  Pramod B Voleti; Keith D Baldwin; Gwo-Chin Lee
Journal:  J Arthroplasty       Date:  2012-07-06       Impact factor: 4.757

3.  Pseudotumor formation and serum ions after large head metal-on-metal stemmed total hip replacement. Risk factors, time course and revisions in 706 hips.

Authors:  B H Bosker; H B Ettema; M van Rossum; M F Boomsma; B J Kollen; M Maas; C C P M Verheyen
Journal:  Arch Orthop Trauma Surg       Date:  2015-02-08       Impact factor: 3.067

4.  [The bursa iliopectinea--a morphologic-computed tomographic study].

Authors:  W Dihlmann; A Peters; B Tillmann
Journal:  Rofo       Date:  1989-03

5.  Comparisons of image quality and radiation dose between iterative reconstruction and filtered back projection reconstruction algorithms in 256-MDCT coronary angiography.

Authors:  Yang Hou; Xin Liu; Shu Xv; Wenli Guo; Qiyong Guo
Journal:  AJR Am J Roentgenol       Date:  2012-09       Impact factor: 3.959

6.  Failure rates of stemmed metal-on-metal hip replacements.

Authors:  Cees C P M Verheyen; Jan A N Verhaar
Journal:  Lancet       Date:  2012-07-14       Impact factor: 79.321

7.  Frequency split metal artefact reduction in pelvic computed tomography.

Authors:  M M Lell; E Meyer; M Schmid; R Raupach; M S May; M Uder; M Kachelriess
Journal:  Eur Radiol       Date:  2013-03-22       Impact factor: 5.315

8.  [Bursa iliopectinea--size and morphology].

Authors:  A Peters; B Tillmann
Journal:  Anat Anz       Date:  1988

9.  Reduction of metal artifacts from hip prostheses on CT images of the pelvis: value of iterative reconstructions.

Authors:  Fabian Morsbach; Sebastian Bickelhaupt; Guido A Wanner; Andreas Krauss; Bernhard Schmidt; Hatem Alkadhi
Journal:  Radiology       Date:  2013-03-19       Impact factor: 11.105

10.  Perivascular and diffuse lymphocytic inflammation are not specific for failed metal-on-metal hip implants.

Authors:  Takaaki Fujishiro; Dirk Jan F Moojen; Naomi Kobayashi; Wouter J A Dhert; Thomas W Bauer
Journal:  Clin Orthop Relat Res       Date:  2010-10-29       Impact factor: 4.176

View more
  6 in total

1.  Use of internal references for assessing CT density measurements of the pelvis as replacement for use of an external phantom.

Authors:  Martijn F Boomsma; Inge Slouwerhof; Jorn A van Dalen; Mireille A Edens; Dirk Mueller; Julien Milles; Mario Maas
Journal:  Skeletal Radiol       Date:  2015-07-16       Impact factor: 2.199

Review 2.  Sequelae of large-head metal-on-metal hip arthroplasties: Current status and future prospects.

Authors:  Christiaan P van Lingen; Luigi M Zagra; Harmen B Ettema; Cees C Verheyen
Journal:  EFORT Open Rev       Date:  2017-03-13

3.  Pseudotumours, cobalt and clinical outcome in small head metal-on-metal versus conventional metal-on-polyethylene total hip arthroplasty.

Authors:  Hugo C van der Veen; Inge Hf Reininga; Wierd P Zijlstra; Martijn F Boomsma; Sjoerd K Bulstra; Jos Jam van Raay
Journal:  Hip Int       Date:  2019-03-06       Impact factor: 2.135

Review 4.  Hip Arthroplasty Pseudotumors: Pathogenesis, Imaging, and Clinical Decision Making.

Authors:  Derik L Davis; James J Morrison
Journal:  J Clin Imaging Sci       Date:  2016-04-29

5.  Quantitative analysis of orthopedic metal artefact reduction in 64-slice computed tomography scans in large head metal-on-metal total hip replacement, a phantom study.

Authors:  Martijn F Boomsma; Niek Warringa; Mireille A Edens; Dirk Mueller; Harmen B Ettema; Cees C P M Verheyen; Mario Maas
Journal:  Springerplus       Date:  2016-04-02

6.  Ten-year results of a prospective cohort of large-head metal-on-metal total hip arthroplasty : a concise follow-up of a previous report.

Authors:  Christiaan P van Lingen; Harmen B Ettema; Bart H Bosker; Cees C P M Verheyen
Journal:  Bone Jt Open       Date:  2022-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.