Literature DB >> 24876620

Statistical transformation and the interpretation of inpatient glucose control data from the intensive care unit.

George E Saulnier1, Janna C Castro1, Curtiss B Cook2.   

Abstract

Glucose control can be problematic in critically ill patients. We evaluated the impact of statistical transformation on interpretation of intensive care unit inpatient glucose control data. Point-of-care blood glucose (POC-BG) data derived from patients in the intensive care unit for 2011 was obtained. Box-Cox transformation of POC-BG measurements was performed, and distribution of data was determined before and after transformation. Different data subsets were used to establish statistical upper and lower control limits. Exponentially weighted moving average (EWMA) control charts constructed from April, October, and November data determined whether out-of-control events could be identified differently in transformed versus nontransformed data. A total of 8679 POC-BG values were analyzed. POC-BG distributions in nontransformed data were skewed but approached normality after transformation. EWMA control charts revealed differences in projected detection of out-of-control events. In April, an out-of-control process resulting in the lower control limit being exceeded was identified at sample 116 in nontransformed data but not in transformed data. October transformed data detected an out-of-control process exceeding the upper control limit at sample 27 that was not detected in nontransformed data. Nontransformed November results remained in control, but transformation identified an out-of-control event less than 10 samples into the observation period. Using statistical methods to assess population-based glucose control in the intensive care unit could alter conclusions about the effectiveness of care processes for managing hyperglycemia. Further study is required to determine whether transformed versus nontransformed data change clinical decisions about the interpretation of care or intervention results.
© 2014 Diabetes Technology Society.

Entities:  

Keywords:  diabetes; hospital; hyperglycemia; inpatient; statistical process control

Mesh:

Substances:

Year:  2014        PMID: 24876620      PMCID: PMC4455452          DOI: 10.1177/1932296814524873

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  24 in total

Review 1.  Glucose measurement: confounding issues in setting targets for inpatient management.

Authors:  Kathleen Dungan; John Chapman; Susan S Braithwaite; John Buse
Journal:  Diabetes Care       Date:  2007-02       Impact factor: 19.112

2.  American Association of Clinical Endocrinologists and American Diabetes Association consensus statement on inpatient glycemic control.

Authors:  Etie S Moghissi; Mary T Korytkowski; Monica DiNardo; Daniel Einhorn; Richard Hellman; Irl B Hirsch; Silvio E Inzucchi; Faramarz Ismail-Beigi; M Sue Kirkman; Guillermo E Umpierrez
Journal:  Endocr Pract       Date:  2009 May-Jun       Impact factor: 3.443

3.  Prevalence of interfering substances with point-of-care glucose testing in a community hospital.

Authors:  John H Eastham; Debra Mason; Deborah L Barnes; Jerry Kollins
Journal:  Am J Health Syst Pharm       Date:  2009-01-15       Impact factor: 2.637

4.  Standards of medical care in diabetes--2013.

Authors: 
Journal:  Diabetes Care       Date:  2013-01       Impact factor: 19.112

5.  The case for using industrial quality management science in health care organizations.

Authors:  G Laffel; D Blumenthal
Journal:  JAMA       Date:  1989-11-24       Impact factor: 56.272

6.  Is there a suitable point-of-care glucose meter for tight glycemic control? Evaluation of one home-use and four hospital-use meters in an intensive care unit.

Authors:  Karlijn Gijzen; David L J Moolenaar; Jos J A M Weusten; Hendrik J Pluim; Ayse Y Demir
Journal:  Clin Chem Lab Med       Date:  2012-11       Impact factor: 3.694

7.  Tighter accuracy standards within point-of-care blood glucose monitoring: how six commonly used systems compare.

Authors:  Charlotte S Robinson; Patrick Sharp
Journal:  J Diabetes Sci Technol       Date:  2012-05-01

8.  Accuracy of bedside glucometry in critically ill patients: influence of clinical characteristics and perfusion index.

Authors:  Arnaud Desachy; Albert C Vuagnat; Aiham D Ghazali; Olivier T Baudin; Olivier H Longuet; Sylvie N Calvat; Valerie Gissot
Journal:  Mayo Clin Proc       Date:  2008-04       Impact factor: 7.616

9.  Accuracy of AccuChek glucose measurement in intensive care patients.

Authors:  Iwan A Meynaar; Margot van Spreuwel; Peter L Tangkau; Lilian Dawson; Steven Sleeswijk Visser; Lode Rijks; Thea Vliet Vlieland
Journal:  Crit Care Med       Date:  2009-10       Impact factor: 7.598

10.  Glucose variability is associated with intensive care unit mortality.

Authors:  Jeroen Hermanides; Titia M Vriesendorp; Robert J Bosman; Durk F Zandstra; Joost B Hoekstra; J Hans Devries
Journal:  Crit Care Med       Date:  2010-03       Impact factor: 7.598

View more
  1 in total

1.  How is the weather? Forecasting inpatient glycemic control.

Authors:  George E Saulnier; Janna C Castro; Curtiss B Cook; Bithika M Thompson
Journal:  Future Sci OA       Date:  2017-09-11
  1 in total