Literature DB >> 24821994

A Prospective Randomized Clinical Trial Comparing 3D and Standard Miniplates in Treatment of Mandibular Symphysis and Parasymphysis Fractures.

Mohit Agarwal1, Balram Meena1, D K Gupta1, Anjali Dave Tiwari1, Sunil Kumar Jakhar1.   

Abstract

PURPOSE: To compare the efficacy of the 3D miniplates to standard miniplates in the osteosynthesis of mandibular symphysis and parasymphysis fractures on the basis of clinical parameters and radiographic evaluation. PATIENTS AND METHODS: A prospective randomized clinical trial was conducted to treat consecutive mandibular symphysis and parasymphysis fractures. The patients were randomly divided into 2 groups. The patients underwent osteosynthesis in group A with 3D titanium miniplates and in group B with conventional titanium miniplates. The cause of trauma, the number of days from injury to surgery, average age and gender were all reviewed. The assessment of the patients was done at 1, 3, and 6 weeks and 3 months using the clinical parameters and radiographic evaluation.
RESULTS: Eighty patients with isolated symphysis or parasymphysis fracture met the inclusion criteria. In our study, a statistically significant difference was not found in the clinical parameters such as pain, swelling, infection, paresthesia, hardware failure, and mobility between the fracture segments. Similarly Radiological evaluation did not show any statistically significant difference in reduction between the 2 groups. 3D plates are difficult to adapt and use sometimes, but operative time is less with them in treatment of symphysis and parasymphysis fractures.
CONCLUSION: The use of 3D miniplates for symphysis and parasymphysis fracture fixation was efficacious enough to bear the masticatory load during osteosynthesis of the fracture. Although 3D miniplate system is difficult to adapt and difficult to use in cases of fractures involving the mental nerve, they provide the advantage of less operative time and less implant material in treatment of symphysis and parasymphysis fracture, with clinical results almost similar to those seen with conventional miniplate osteosynthesis.

Entities:  

Keywords:  3D miniplates; 3D plates; Mandible fracture; Mandibular symphysis; Symphysis and parasymphysis fracture

Year:  2013        PMID: 24821994      PMCID: PMC4016401          DOI: 10.1007/s12663-013-0483-x

Source DB:  PubMed          Journal:  J Maxillofac Oral Surg        ISSN: 0972-8270


  13 in total

1.  [The value of 3-dimensional plates in maxillofacial surgery].

Authors:  M Farmand; L Dupoirieux
Journal:  Rev Stomatol Chir Maxillofac       Date:  1992

2.  [Mandibular osteosynthesis according to the Michelet technic. I. Biomechanical bases].

Authors:  M Champy; J P Lodde; J H Jaeger; A Wilk
Journal:  Rev Stomatol Chir Maxillofac       Date:  1976 Apr-May

3.  Treatment modalities for mandibular angle fractures.

Authors:  Andrew J L Gear; Elena Apasova; John P Schmitz; Warren Schubert
Journal:  J Oral Maxillofac Surg       Date:  2005-05       Impact factor: 1.895

4.  The use of miniplates in mandibular fractures. An in vitro study.

Authors:  F H Kroon; M Mathisson; J R Cordey; B A Rahn
Journal:  J Craniomaxillofac Surg       Date:  1991-07       Impact factor: 2.078

5.  Complications of miniplate osteosynthesis for mandibular fractures.

Authors:  S Nakamura; Y Takenoshita; M Oka
Journal:  J Oral Maxillofac Surg       Date:  1994-03       Impact factor: 1.895

6.  Biomechanical evaluation of new fixation devices for mandibular angle fractures.

Authors:  J M Wittenberg; D P Mukherjee; B R Smith; R N Kruse
Journal:  Int J Oral Maxillofac Surg       Date:  1997-02       Impact factor: 2.789

7.  Comparison of 3-dimensional and standard miniplate fixation in the management of mandibular fractures.

Authors:  Manoj Kumar Jain; K S Manjunath; B K Bhagwan; Dipit K Shah
Journal:  J Oral Maxillofac Surg       Date:  2010-04-22       Impact factor: 1.895

8.  Use of straight and curved 3-dimensional titanium miniplates for fracture fixation at the mandibular angle.

Authors:  Juergen Zix; Olivier Lieger; Tateyuki Iizuka
Journal:  J Oral Maxillofac Surg       Date:  2007-09       Impact factor: 1.895

9.  [Experimental study on the biomechanical stability of different internal fixators for use in the mandible].

Authors:  J Piffkò; Ch Homann; R Schuon; U Joos; U Meyer
Journal:  Mund Kiefer Gesichtschir       Date:  2002-10-11

10.  Mandibular osteosynthesis by miniature screwed plates via a buccal approach.

Authors:  M Champy; J P Loddé; R Schmitt; J H Jaeger; D Muster
Journal:  J Maxillofac Surg       Date:  1978-02
View more
  6 in total

1.  The 3-dimensional miniplate is more effective than the standard miniplate for the management of mandibular fractures: a meta-analysis.

Authors:  Yong Liu; Bo Wei; Yuxiang Li; Dawei Gu; Guochao Yin; Bo Wang; Dehui Xu; Xuebing Zhang; Daliang Kong
Journal:  Eur J Med Res       Date:  2017-02-14       Impact factor: 2.175

2.  Evaluation of efficacy of intermaxillary fixation screws versus modified arch bar for intermaxillary fixation.

Authors:  Tushar Manohar Rothe; Prachur Kumar; Navin Shah; Rakesh Shah; Ananth Kumar; Devika Das
Journal:  Natl J Maxillofac Surg       Date:  2018 Jul-Dec

3.  Three-dimensional versus standard miniplate, lag screws versus miniplates, locking plate versus non-locking miniplates: Management of mandibular fractures, a systematic review and meta-analysis.

Authors:  Patiguli Wusiman; Dilidaer Taxifulati; Li Weidong; Adili Moming
Journal:  J Dent Sci       Date:  2019-01-14       Impact factor: 2.080

4.  Effectiveness of placement of second miniplates as tension band unit in mandibular parasymphysis fractures.

Authors:  Javad Yazdani; MohamadAli Ghavimi; Mahsa Taghizadeh; Yousef Kananizadeh; Milad Ghanizadeh
Journal:  Dent Res J (Isfahan)       Date:  2019 May-Jun

5.  Comparative Evaluation of Efficacy of Conventional Arch Bar, Intermaxillary Fixation Screws, and Modified Arch Bar for Intermaxillary Fixation.

Authors:  Tushar Manohar Rothe; Prachur Kumar; Navin Shah; Rakesh Shah; Amit Mahajan; Ananth Kumar
Journal:  J Maxillofac Oral Surg       Date:  2018-04-19

6.  Evaluation of labial versus labio-inferior lines of osteosynthesis using 3D miniplate for fractures of anterior mandible: A finite element analysis with a pilot clinical trial.

Authors:  Keerthana Ponvel; Elavenil Panneerselvam; Sasikala Balasubramanian; V B Krishna Kumar Raja
Journal:  Chin J Traumatol       Date:  2019-08-09
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.