Literature DB >> 1475603

[The value of 3-dimensional plates in maxillofacial surgery].

M Farmand1, L Dupoirieux.   

Abstract

Plate osteosynthesis for bone fragment stabilisation in maxillo-facial surgery is a universal method whose advantages and drawbacks are now well documented. A new system of plates made out of titanium (3-D plates) is presented. The geometry of the plate assures a good stability in the three dimensions of the space. Easy use, good resistance against torque forces, compact form of the plate are some of the advantages. Various clinical cases are presented.

Mesh:

Year:  1992        PMID: 1475603

Source DB:  PubMed          Journal:  Rev Stomatol Chir Maxillofac        ISSN: 0035-1768


  19 in total

1.  Efficacy of 3-Dimensional plates over Champys miniplates in mandibular anterior fractures.

Authors:  Dhananjay H Barde; Anupama Mudhol; Fareedi Mukram Ali; R S Madan; Sanjay Kar; Farheen Ustaad
Journal:  J Int Oral Health       Date:  2014-02-26

2.  Versatility of Titanium 3D Plate in Comparison with Conventional Titanium Miniplate Fixation for the Management of Mandibular Fracture.

Authors:  Kamal Malhotra; Ashish Sharma; Girish Giraddi; Ashish Kumar Shahi
Journal:  J Maxillofac Oral Surg       Date:  2012-03-29

3.  Development and Clinical Evaluation of MatrixMANDIBLE Subcondylar Plates System (Synthes).

Authors:  Roberto Cortelazzi; Mario Altacera; Monica Turco; Viviana Antonicelli; Michele De Benedittis
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2014-10-31

4.  A Comparative Study of 3-Dimensional Titanium Versus 2-Dimensional Titanium Miniplates for Open Reduction and Fixation of Mandibular Parasymphysis Fracture.

Authors:  Yogesh Mittal; K George Varghese; S Mohan; N Jayakumar; Somil Chhag
Journal:  J Maxillofac Oral Surg       Date:  2015-03-27

5.  Management of Mandibular Angle Fractures: Single Stainless Steel Linear Miniplate Versus Rectangular Grid Plate-A Prospective Randomised Study.

Authors:  Sridhar Reddy Kanubaddy; Sathya Kumar Devireddy; Kishore Kumar Rayadurgam; Rajsekhar Gali; Mallikarjun Rao Dasari; Sivaganesh Pampana
Journal:  J Maxillofac Oral Surg       Date:  2016-03-31

6.  Comparative Evaluation of Conventional Miniplates, Three-Dimensional Miniplates and Lag Screws for Internal Fixation of Parasymphysis Fracture of Mandible-A Double-Blind Randomized Clinical Study.

Authors:  Revanth Kumar Salavadi; Ramen Sinha; Ashwant Kumar Vadepally; Uday Kiran Uppada
Journal:  J Maxillofac Oral Surg       Date:  2021-09-24

7.  Evaluation of 2.0-mm Titanium Three-Dimensional Curved Angle Strut Plate in the Fixation of Mandibular Angle Fractures-A Prospective Clinical and Radiological Analysis.

Authors:  Gaurav Chhabaria; Rajshekhar Halli; Sanjay Chandan; Samir Joshi; Sneha Setiya; Anand Shah
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2014-02-20

8.  A Prospective Randomized Clinical Trial Comparing 3D and Standard Miniplates in Treatment of Mandibular Symphysis and Parasymphysis Fractures.

Authors:  Mohit Agarwal; Balram Meena; D K Gupta; Anjali Dave Tiwari; Sunil Kumar Jakhar
Journal:  J Maxillofac Oral Surg       Date:  2013-02-15

9.  3-D Miniplates Versus Conventional Miniplates in Treatment of Mandible Fractures.

Authors:  Niranjan Mishra; Nirav Thakkar; Indubhusan Kar; Shadab Ali Baig; Gaurav Sharma; Rosalin Kar; Gyana Ranjan Sahu; Krishna Gopal Birmiwal
Journal:  J Maxillofac Oral Surg       Date:  2017-12-14

10.  Novel Use of Orbita Plates in Mandibular Body Fractures.

Authors:  Sonal Anchlia; Jigar M Dhuvad; Dhruvi Shukla; Rohit Kumar; Nisarg Patel; Vipul Nagavadiya
Journal:  J Maxillofac Oral Surg       Date:  2018-02-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.