Literature DB >> 24819560

Accuracy of ultrasound B-lines score and E/Ea ratio to estimate extravascular lung water and its variations in patients with acute respiratory distress syndrome.

Benoît Bataille1, Guillaume Rao, Pierre Cocquet, Michel Mora, Bruno Masson, Jean Ginot, Stein Silva, Pierre-Etienne Moussot.   

Abstract

Extravascular lung water (EVLW) could increase by permeability pulmonary oedema, cardiogenic oedema, or both. Transthoracic echocardiography examination of a patient allows quantifying B-lines, originating from water-thickened interlobular septa, and the E/Ea ratio, related to pulmonary capillary wedge pressure. The aim of our study was to assess the correlation and the trending ability between EVLW measured by transpulmonary thermodilution and the B-lines score or the E/Ea ratio in patients with ARDS. Twenty-six intensive care unit patients were prospectively included. B-lines score was obtained from four ultrasound zones (anterior and lateral chest on left and right hemithorax). E/Ea was measured from the apical four-chamber view. EVLW was compared with the B-lines score and the E/Ea ratio. A linear mixed effect model was used to take account the repeated measurements. A p value<0.05 was considered significant. A total of 73 measurements were collected. The correlation coefficient between EVLW and B-lines score was 0.66 (EVLW=0.71 B-lines+7.64, R2=0.44, p=0.001), versus 0.31 for E/Ea (p=0.06). The correlation between EVLW changes and B-lines variations was significant (R2=0.26, p<0.01), with a concordance rate of 74%. A B-lines score≥6 had a sensitivity of 82% and a specificity of 77% to predict EVLW>10 ml/kg, with an AUC equal to 0.86 (0.76-0.93). The gray zone approach identified a range of B-lines between four and seven for which EVLW>10 ml/kg could not be predicted reliably. The correlation between ultrasound B-lines and EVLW was significant, but the B-lines score was not able to track EVLW changes reliably.

Entities:  

Mesh:

Year:  2014        PMID: 24819560     DOI: 10.1007/s10877-014-9582-6

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  36 in total

1.  Clinical utility of Doppler echocardiography and tissue Doppler imaging in the estimation of left ventricular filling pressures: A comparative simultaneous Doppler-catheterization study.

Authors:  S R Ommen; R A Nishimura; C P Appleton; F A Miller; J K Oh; M M Redfield; A J Tajik
Journal:  Circulation       Date:  2000-10-10       Impact factor: 29.690

2.  A randomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients.

Authors:  James Dean Sandham; Russell Douglas Hull; Rollin Frederick Brant; Linda Knox; Graham Frederick Pineo; Christopher J Doig; Denny P Laporta; Sidney Viner; Louise Passerini; Hugh Devitt; Ann Kirby; Michael Jacka
Journal:  N Engl J Med       Date:  2003-01-02       Impact factor: 91.245

Review 3.  A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output.

Authors:  Lester A Critchley; Anna Lee; Anthony M-H Ho
Journal:  Anesth Analg       Date:  2010-08-24       Impact factor: 5.108

4.  Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a "gray zone" approach.

Authors:  Maxime Cannesson; Yannick Le Manach; Christoph K Hofer; Jean Pierre Goarin; Jean-Jacques Lehot; Benoît Vallet; Benoît Tavernier
Journal:  Anesthesiology       Date:  2011-08       Impact factor: 7.892

5.  Can changes in arterial pressure be used to detect changes in cardiac output during volume expansion in the perioperative period?

Authors:  Yannick Le Manach; Christoph K Hofer; Jean-Jacques Lehot; Benoît Vallet; Jean-Pierre Goarin; Benoît Tavernier; Maxime Cannesson
Journal:  Anesthesiology       Date:  2012-12       Impact factor: 7.892

Review 6.  The transpulmonary thermodilution technique.

Authors:  Samir G Sakka; Daniel A Reuter; Azriel Perel
Journal:  J Clin Monit Comput       Date:  2012-07-18       Impact factor: 2.502

7.  Factors influencing the estimation of extravascular lung water by transpulmonary thermodilution in critically ill patients.

Authors:  Frédéric Michard; Alexander Schachtrupp; Christian Toens
Journal:  Crit Care Med       Date:  2005-06       Impact factor: 7.598

8.  A prospective study of lung water measurements during patient management in an intensive care unit.

Authors:  P R Eisenberg; J R Hansbrough; D Anderson; D P Schuster
Journal:  Am Rev Respir Dis       Date:  1987-09

9.  Isolated and reversible impairment of ventricular relaxation in patients with septic shock.

Authors:  Bélaïd Bouhemad; Armelle Nicolas-Robin; Charlotte Arbelot; Martine Arthaud; Frédéric Féger; Jean-Jacques Rouby
Journal:  Crit Care Med       Date:  2008-03       Impact factor: 7.598

10.  Relationship between extravascular lung water and severity categories of acute respiratory distress syndrome by the Berlin definition.

Authors:  Shigeki Kushimoto; Tomoyuki Endo; Satoshi Yamanouchi; Teruo Sakamoto; Hiroyasu Ishikura; Yasuhide Kitazawa; Yasuhiko Taira; Kazuo Okuchi; Takashi Tagami; Akihiro Watanabe; Junko Yamaguchi; Kazuhide Yoshikawa; Manabu Sugita; Yoichi Kase; Takashi Kanemura; Hiroyuki Takahashi; Yuuichi Kuroki; Hiroo Izumino; Hiroshi Rinka; Ryutarou Seo; Makoto Takatori; Tadashi Kaneko; Toshiaki Nakamura; Takayuki Irahara; Nobuyuki Saito
Journal:  Crit Care       Date:  2013-06-20       Impact factor: 9.097

View more
  12 in total

1.  Strong correlation between lung ultrasound and chest computerized tomography imaging for the detection of acute lung injury/acute respiratory distress syndrome in rats.

Authors:  Huan Ma; Daozheng Huang; Liheng Guo; Quanfu Chen; Wenzhao Zhong; Qingshan Geng; Minzhou Zhang
Journal:  J Thorac Dis       Date:  2016-07       Impact factor: 2.895

2.  Lung Ultrasound to Assist ICU Admission Decision-Making Process of COVID-19 Patients With Acute Respiratory Failure.

Authors:  Amazigh Aguersif; Benjamine Sarton; Sihem Bouharaoua; Lucien Gaillard; Denis Standarovski; Orphée Faucoz; Guillaume Martin Blondel; Hatem Khallel; Claire Thalamas; Agnes Sommet; Béatrice Riu; Eric Morand; Benoit Bataille; Stein Silva
Journal:  Crit Care Explor       Date:  2022-06-08

3.  Accuracy of pulse pressure variations for fluid responsiveness prediction in mechanically ventilated patients with biphasic positive airway pressure mode.

Authors:  Benoît Bataille; David Le Moal; Thomas Renault; Pierre Cocquet; Jade de Selle; Stein Silva
Journal:  J Clin Monit Comput       Date:  2021-12-05       Impact factor: 1.977

Review 4.  Lung B-line artefacts and their use.

Authors:  Christoph F Dietrich; Gebhard Mathis; Michael Blaivas; Giovanni Volpicelli; Armin Seibel; Daniel Wastl; Nathan S S Atkinson; Xin-Wu Cui; Mei Fan; Dong Yi
Journal:  J Thorac Dis       Date:  2016-06       Impact factor: 2.895

5.  Endothelial glycocalyx degradation is associated with early organ impairment in polytrauma patients.

Authors:  Feng Qi; Hao Zhou; Peng Gu; Zhi-He Tang; Bao-Feng Zhu; Jian-Rong Chen; Jin-Song Zhang; Feng Li
Journal:  BMC Emerg Med       Date:  2021-04-20

Review 6.  Lung ultrasound: a promising tool to monitor ventilator-associated pneumonia in critically ill patients.

Authors:  Guyi Wang; Xiaoying Ji; Yongshan Xu; Xudong Xiang
Journal:  Crit Care       Date:  2016-10-27       Impact factor: 9.097

7.  The Effects of High-volume Hemofiltration by Different Ultrasound Directing on Extra Vascular Lung Water Index in Patients with Septic Shock.

Authors:  Hongsheng Ren; Bo Song; Pengcheng Li; Cheng Huan; Yufeng Chu; Min Ding; Yuping Wang; Qingchun Yao; Peng Wang; Guoqiang Qi; Chunting Wang
Journal:  Iran J Public Health       Date:  2018-09       Impact factor: 1.429

8.  Point-of-care lung ultrasound for the detection of pulmonary manifestations of malaria and sepsis: An observational study.

Authors:  Stije J Leopold; Aniruddha Ghose; Katherine A Plewes; Subash Mazumder; Luigi Pisani; Hugh W F Kingston; Sujat Paul; Anupam Barua; M Abdus Sattar; Michaëla A M Huson; Andrew P Walden; Patricia C Henwood; Elisabeth D Riviello; Marcus J Schultz; Nicholas P J Day; Asok Kumar Dutta; Nicholas J White; Arjen M Dondorp
Journal:  PLoS One       Date:  2018-12-12       Impact factor: 3.240

Review 9.  Multi-organ point-of-care ultrasound for COVID-19 (PoCUS4COVID): international expert consensus.

Authors:  Arif Hussain; Gabriele Via; Lawrence Melniker; Alberto Goffi; Guido Tavazzi; Luca Neri; Tomas Villen; Richard Hoppmann; Francesco Mojoli; Vicki Noble; Laurent Zieleskiewicz; Pablo Blanco; Irene W Y Ma; Mahathar Abd Wahab; Abdulmohsen Alsaawi; Majid Al Salamah; Martin Balik; Diego Barca; Karim Bendjelid; Belaid Bouhemad; Pablo Bravo-Figueroa; Raoul Breitkreutz; Juan Calderon; Jim Connolly; Roberto Copetti; Francesco Corradi; Anthony J Dean; André Denault; Deepak Govil; Carmela Graci; Young-Rock Ha; Laura Hurtado; Toru Kameda; Michael Lanspa; Christian B Laursen; Francis Lee; Rachel Liu; Massimiliano Meineri; Miguel Montorfano; Peiman Nazerian; Bret P Nelson; Aleksandar N Neskovic; Ramon Nogue; Adi Osman; José Pazeli; Elmo Pereira-Junior; Tomislav Petrovic; Emanuele Pivetta; Jan Poelaert; Susanna Price; Gregor Prosen; Shalim Rodriguez; Philippe Rola; Colin Royse; Yale Tung Chen; Mike Wells; Adrian Wong; Wang Xiaoting; Wang Zhen; Yaseen Arabi
Journal:  Crit Care       Date:  2020-12-24       Impact factor: 9.097

10.  Lung ultrasound is a reliable method for evaluating extravascular lung water volume in rodents.

Authors:  Huan Ma; Daozheng Huang; Minzhou Zhang; Xin Huang; Shiyu Ma; Shuai Mao; Wenhui Li; Yanfen Chen; Liheng Guo
Journal:  BMC Anesthesiol       Date:  2015-11-12       Impact factor: 2.217

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.