Literature DB >> 15942338

Factors influencing the estimation of extravascular lung water by transpulmonary thermodilution in critically ill patients.

Frédéric Michard1, Alexander Schachtrupp, Christian Toens.   

Abstract

OBJECTIVE: To investigate factors that may influence the estimation of extravascular lung water (EVLW) with a single (cold) indicator compared with assessment using two indicators (thermo-dye dilution).
DESIGN: Post hoc analysis of an electronic hemodynamic database.
SETTING: Surgical intensive care unit of a university hospital. PATIENTS: Forty-eight critically ill patients monitored by the thermo-dye dilution technique in the postoperative period.
INTERVENTIONS: None.
MEASUREMENTS AND MAIN RESULTS: The EVLW was simultaneously assessed by the thermo-dye dilution technique (EVLWref) and estimated by transpulmonary thermodilution (EVLWest). EVLWref index ranged between 1 and 40 mL/kg (mean 10 +/- 7 mL/kg) and EVLWest between 2 and 39 mL/kg (mean 9 +/- 6 mL/kg). EVLWref was closely correlated (r = .96) with EVLWest. The mean difference (bias) between EVLWref and EVLWest was -0.5 +/- 1.9 mL/kg. The bias was not influenced by the weight, height, body surface area, body mass index, Pao2, intrathoracic blood volume, cardiac output, or dosage of vasoactive agents. In contrast, the bias was slightly but significantly influenced by EVLWref, Pao2/Fio2 ratio, tidal volume, and level of positive end-expiratory pressure.
CONCLUSIONS: In our surgical intensive care unit population, the estimation of EVLW by transpulmonary thermodilution was influenced by the amount of EVLW, the Pao2/Fio2 ratio, the tidal volume, and the level of positive end-expiratory pressure. However, compared with the double indicator method, transpulmonary thermodilution estimation remained clinically acceptable even in patients with severe lung disease.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15942338     DOI: 10.1097/01.ccm.0000164566.23147.35

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  22 in total

1.  Impact of misplaced subclavian vein catheter into jugular vein on transpulmonary thermodilution measurement variables.

Authors:  Wen-qiao Yu; Yun Zhang; Shao-yang Zhang; Zhong-yan Liang; Shui-qiao Fu; Jia Xu; Ting-bo Liang
Journal:  J Zhejiang Univ Sci B       Date:  2016-01       Impact factor: 3.066

Review 2.  Measurement of extravascular lung water using the single indicator method in patients: research and potential clinical value.

Authors:  Lisa M Brown; Kathleen D Liu; Michael A Matthay
Journal:  Am J Physiol Lung Cell Mol Physiol       Date:  2009-07-17       Impact factor: 5.464

3.  Effect of Repeated Recruitment Manoeuvres on Patients with Severe Acute Respiratory Distress Syndrome.

Authors:  M-Q Li; G-J Han; J-Q Li; J-Y Xu; Z-X Shi; Z Zhang; F Lu; X-M Wang; Y-J Xu; X Mo
Journal:  West Indian Med J       Date:  2015-05-15       Impact factor: 0.171

4.  Extravascular lung water to blood volume ratios as measures of permeability in sepsis-induced ALI/ARDS.

Authors:  A B Johan Groeneveld; Joanne Verheij
Journal:  Intensive Care Med       Date:  2006-06-02       Impact factor: 17.440

5.  Lung water assessment: from gravimetry to wearables.

Authors:  Frederic Michard
Journal:  J Clin Monit Comput       Date:  2018-05-11       Impact factor: 2.502

6.  Accuracy of ultrasound B-lines score and E/Ea ratio to estimate extravascular lung water and its variations in patients with acute respiratory distress syndrome.

Authors:  Benoît Bataille; Guillaume Rao; Pierre Cocquet; Michel Mora; Bruno Masson; Jean Ginot; Stein Silva; Pierre-Etienne Moussot
Journal:  J Clin Monit Comput       Date:  2014-05-13       Impact factor: 2.502

7.  Influence of extravascular lung water on transpulmonary thermodilution-derived cardiac output measurement.

Authors:  Thomas Pohl; Jan Kozieras; Samir G Sakka
Journal:  Intensive Care Med       Date:  2007-11-03       Impact factor: 17.440

8.  Alveolar fluid clearance in healthy pigs and influence of positive end-expiratory pressure.

Authors:  Manuel García-Delgado; Angel Touma-Fernández; Virginia Chamorro-Marín; Antonio Ruiz-Aguilar; Eduardo Aguilar-Alonso; Enrique Fernández-Mondéjar
Journal:  Crit Care       Date:  2010-03-16       Impact factor: 9.097

9.  Transpulmonary thermodilution using femoral indicator injection: a prospective trial in patients with a femoral and a jugular central venous catheter.

Authors:  Bernd Saugel; Andreas Umgelter; Tibor Schuster; Veit Phillip; Roland M Schmid; Wolfgang Huber
Journal:  Crit Care       Date:  2010-05-25       Impact factor: 9.097

10.  Global end-diastolic volume acquired by transpulmonary thermodilution depends on age and gender in awake and spontaneously breathing patients.

Authors:  Stefan Wolf; Alexander Riess; Julia F Landscheidt; Christianto B Lumenta; Patrick Friederich; Ludwig Schürer
Journal:  Crit Care       Date:  2009-12-14       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.