Accuracy of bedside glucometry in critically ill children with peripheral hypoperfusion.

Anant Khositseth1, Onsuthi Pharadornuwat, Rojjanee Lertbunrian, Nattachai Anantasit, Jarin Vaewpanich.   

Abstract

The accuracy of glucose test strip in critically care has been questioned. We investigated the accuracy of glucose test strip in critically ill children. Patients, aged from 1 month to 18 years admitted in pediatric intensive care unit. Demographic data, hemodynamic parameters, and perfusion index (PI) were recorded. Glucose test strips were performed from finger stick blood [capillary blood glucose (CBG)] and from whole blood [whole blood glucose (WBG)] along with laboratory plasma blood glucose (PBG) from either arterial or venous blood samples. The accuracy of glucose test strips was defined according to ISO 15197 and Clarke error grid (CEG). One hundred and eighty one blood samplings including 117 arterial blood (CBG, WBGa, PBGa) and 64 venous blood (CBG, WBGv, PBGv) were obtained. The accuracy of WBGa was 98.3 and 95.2% when compared to the accuracy of CBG (88.7 and 83.3%. The accuracy of WBGv was 92.2% and 87.0 when compared to the accuracy of CBG which was 79.7 and 72.9% (ISO 15197: 2003 and 2013, respectively). Bland-Altman plot demonstrated bias and precision of 7.4±17.7 mg/dL in acceptable PI group compared to 30.2±23.4 mg/dL in low PI group (PI≤0.3). The CBG test strip must be interpreted carefully in critically ill children. A low PI was associated with poor CBG strip accuracy. WBG test strip from arterial blood was more appropriate for glucose monitoring in children with peripheral hypoperfusion.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24801361     DOI: 10.1007/s10877-014-9579-1

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  13 in total

1.  Analytical validation of the new plasma calibrated Accu-Chek Test Strips (Roche Diagnostics).

Authors:  Cécile Meex; José Poncin; Jean-Paul Chapelle; Etienne Cavalier
Journal:  Clin Chem Lab Med       Date:  2006       Impact factor: 3.694

Review 2.  A tale of two compartments: interstitial versus blood glucose monitoring.

Authors:  Eda Cengiz; William V Tamborlane
Journal:  Diabetes Technol Ther       Date:  2009-06       Impact factor: 6.118

3.  Evaluating clinical accuracy of systems for self-monitoring of blood glucose.

Authors:  W L Clarke; D Cox; L A Gonder-Frederick; W Carter; S L Pohl
Journal:  Diabetes Care       Date:  1987 Sep-Oct       Impact factor: 19.112

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Reliability of point-of-care testing for glucose measurement in critically ill adults.

Authors:  Salmaan Kanji; Jennifer Buffie; Brian Hutton; Peter S Bunting; Avinder Singh; Kevin McDonald; Dean Fergusson; Lauralyn A McIntyre; Paul C Hebert
Journal:  Crit Care Med       Date:  2005-12       Impact factor: 7.598

6.  Accuracy of bedside capillary blood glucose measurements in critically ill patients.

Authors:  C Dana Critchell; Vincent Savarese; Amy Callahan; Christine Aboud; Serge Jabbour; Paul Marik
Journal:  Intensive Care Med       Date:  2007-09-01       Impact factor: 17.440

7.  Accuracy of bedside glucometry in critically ill patients: influence of clinical characteristics and perfusion index.

Authors:  Arnaud Desachy; Albert C Vuagnat; Aiham D Ghazali; Olivier T Baudin; Olivier H Longuet; Sylvie N Calvat; Valerie Gissot
Journal:  Mayo Clin Proc       Date:  2008-04       Impact factor: 7.616

8.  Accuracy of AccuChek glucose measurement in intensive care patients.

Authors:  Iwan A Meynaar; Margot van Spreuwel; Peter L Tangkau; Lilian Dawson; Steven Sleeswijk Visser; Lode Rijks; Thea Vliet Vlieland
Journal:  Crit Care Med       Date:  2009-10       Impact factor: 7.598

9.  Use of a peripheral perfusion index derived from the pulse oximetry signal as a noninvasive indicator of perfusion.

Authors:  Alexandre Pinto Lima; Peter Beelen; Jan Bakker
Journal:  Crit Care Med       Date:  2002-06       Impact factor: 7.598

10.  Early dynamic changes in pulse oximetry signals in preterm newborns with histologic chorioamnionitis.

Authors:  Claudio De Felice; Mitchell R Goldstein; Stefano Parrini; Alberto Verrotti; Mario Criscuolo; Giuseppe Latini
Journal:  Pediatr Crit Care Med       Date:  2006-03       Impact factor: 3.624

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.