Literature DB >> 9002833

Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys.

F Isidor1.   

Abstract

The breakdown of bone around oral implants following excessive occlusal load or plaque accumulation was evaluated in monkeys. 5 screw type implants of pure titanium (Astra) were inserted in the mandible of 4 monkeys (Macaca Fascicularis). 2 implants were placed in each of the lateral segments and 1 in the frontal area. Each monkey was provided with 2 cemented splints covering the premolars and molars in the right and left side of the maxilla, respectively. 6 months after insertion of the fixtures, a fixed partial prosthesis was mounted on the 2 implants in one of the lateral segments. The prosthesis was in supra-occlusal contact with the antagonizing splint. Each prosthesis was replaced during the course of the experiment. The renewed prosthesis caused a lateral displacement of the mandible during occlusion, and therefore resulted in a lateral rather than axial excessive occlusal load. Implants retaining the prosthesis were brushed 1 x a week and subgingival cleaning was performed 1 x a month. The remaining implants were never cleaned and, additionally, a cotton cord was placed passively around each of these to promote plaque accumulation. 5 out of 8 implants with excessive occlusal load lost osseointegration (mobility and peri-implant radiolucency). The loss of osseointegration was observed 4.5 months to 15.5 months after the occlusal overload was commenced. None of the implants with plaque accumulation lost osseointegration, although an average loss of 1.8 mm in the radiographic bone level was assessed after 18 months.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9002833     DOI: 10.1034/j.1600-0501.1996.070208.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  49 in total

Review 1.  Interventions for replacing missing teeth: treatment of peri-implantitis.

Authors:  Marco Esposito; Maria Gabriella Grusovin; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2012-01-18

2.  Precision of an instrumentation-based method of analyzing occlusion and its resulting distribution of forces in the dental arch.

Authors:  Bernd Koos; Arnim Godt; Christine Schille; Gernot Göz
Journal:  J Orofac Orthop       Date:  2010-11-17       Impact factor: 1.938

3.  Time-dependent analysis and representation of force distribution and occlusion contact in the masticatory cycle.

Authors:  Bernd Koos; Johanna Höller; Christine Schille; Arnim Godt
Journal:  J Orofac Orthop       Date:  2012-05-13       Impact factor: 1.938

4.  Bacterial contamination along implant-abutment interface in external and internal-hex dental implants.

Authors:  Greison Rabelo de Oliveira; Sergio Olate; Leandro Pozzer; Lucas Cavalieri-Pereira; Jaime G Rodrigues-Chessa; José Ricardo Albergaría-Barbosa
Journal:  Int J Clin Exp Med       Date:  2014-03-15

5.  Two stage surgery in IV Class of Misch with SIS device: a case report.

Authors:  C Grandi; L Pacifici
Journal:  Oral Implantol (Rome)       Date:  2009-04-20

6.  Sinus implants stabilization in Misch IV Class by means of S.I.S. device: A Clinical Study.

Authors:  C Grandi; L Pacifici
Journal:  Oral Implantol (Rome)       Date:  2010-05-25

7.  Peri-implantitis. Part 2: Prevention and maintenance of peri-implant health.

Authors:  A Alani; K Bishop
Journal:  Br Dent J       Date:  2014-09       Impact factor: 1.626

8.  Biomechanical consequences of progressive marginal bone loss around oral implants: a finite element stress analysis.

Authors:  Kivanc Akca; Murat Cavit Cehreli
Journal:  Med Biol Eng Comput       Date:  2006-06-10       Impact factor: 2.602

9.  Lateral static overload on immediately restored implants decreases the osteocyte index in peri-implant bone: a secondary analysis of a pre-clinical study in dogs.

Authors:  Celson Domingos de Calais; Dimorvan Bordin; Adriano Piattelli; Giovanna Iezzi; Alexandre Negretto; Jamil A Shibli
Journal:  Clin Oral Investig       Date:  2020-11-05       Impact factor: 3.573

10.  Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current concepts.

Authors:  Judy Chia-Chun Yuan; Cortino Sukotjo
Journal:  J Periodontal Implant Sci       Date:  2013-04-30       Impact factor: 2.614

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.