Preload loss and bacterial penetration on different implant-abutment connection systems.

Antônio Pedro Ricomini Filho1, Frederico Silva de Freitas Fernandes, Fabiana Gouveia Straioto, Wander José da Silva, Altair Antoninha Del Bel Cury.   

Abstract

Preload loss can favor the occurrence of implant-abutment interface misfit, and bacterial colonization at this interface may lead to implant failure. The aim of this study was to evaluate the preload loss and bacterial penetration through the implant-abutment interface of conical and external hexagon connection systems subjected to thermal cycling and mechanical fatigue (TM). Four different implant-abutment connection systems were evaluated (n=6): external hexagon with universal post, Morse taper with universal post, Morse taper with universal post through bolt, and locking taper with standard abutment. The assemblies (implant-abutment) were subjected to a thermal cycling regimen (1,000 cycles of 5 degrees C and 55 degrees C) and to mechanical fatigue (1.0 million cycles, 1.0 Hz, 120 N). The assemblies were immersed in Tryptic Soy + Yeast Extract broth containing Streptococcus sanguinis and incubated at 37 degrees C and 10% CO(2) for 72 h. Detorque values were recorded. The bacterial penetration was assessed and the abutments were observed by scanning electron microscopy. The preload data were analyzed statistically by two-way ANOVA and Tukey's test at 5% significance level. All screw abutment systems showed significantly higher (p<0.05) detorque values when subjected to TM and all conical systems presented bacterial penetration. The results show no relationship between the preload loss and the bacterial penetration.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20640358     DOI: 10.1590/s0103-64402010000200006

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  14 in total

1.  Bacterial contamination along implant-abutment interface in external and internal-hex dental implants.

Authors:  Greison Rabelo de Oliveira; Sergio Olate; Leandro Pozzer; Lucas Cavalieri-Pereira; Jaime G Rodrigues-Chessa; José Ricardo Albergaría-Barbosa
Journal:  Int J Clin Exp Med       Date:  2014-03-15

2.  In vitro analysis of the microbiological sealing of tapered implants after mechanical cycling.

Authors:  Deceles Cristina Costa Alves; Paulo Sérgio Perri de Carvalho; Carlos Nelson Elias; Eduardo Vedovatto; Elizabeth Ferreira Martinez
Journal:  Clin Oral Investig       Date:  2016-02-20       Impact factor: 3.573

3.  Wear of Morse taper and external hexagon implant joints after abutment removal.

Authors:  Abraão M Prado; Jorge Pereira; Filipe S Silva; Bruno Henriques; Rubens M Nascimento; Cesar A M Benfatti; José López-López; Júlio C M Souza
Journal:  J Mater Sci Mater Med       Date:  2017-03-20       Impact factor: 3.896

Review 4.  Is the internal connection more efficient than external connection in mechanical, biological, and esthetical point of views? A systematic review.

Authors:  Marcelo Coelho Goiato; Eduardo Piza Pellizzer; Emily Vivianne Freitas da Silva; Liliane da Rocha Bonatto; Daniela Micheline dos Santos
Journal:  Oral Maxillofac Surg       Date:  2015-04-25

5.  Micro-leakage at the implant-abutment interface with different tightening torques in vitro.

Authors:  João Paulo da Silva-Neto; Marcel Santana Prudente; Thiago de Almeida Prado Naves Carneiro; Mauro Antônio de Arruda Nóbilo; Mario Paulo Amante Penatti; Flávio Domingues das Neves
Journal:  J Appl Oral Sci       Date:  2012 Sep-Oct       Impact factor: 2.698

6.  Stability of external and internal implant connections after a fatigue test.

Authors:  Paulo Cesar Pinheiro Feitosa; Ana Paula Barbosa de Lima; Laís Regiane Silva-Concílio; William Cunha Brandt; Ana Christina Claro Neves
Journal:  Eur J Dent       Date:  2013-07

7.  Morse Taper Connection Implants Placed in Grafted Sinuses in 65 Patients: A Retrospective Clinical Study with 10 Years of Follow-Up.

Authors:  Francesco Mangano; Renata Bakaj; Irene Frezzato; Alberto Frezzato; Sergio Montini; Carlo Mangano
Journal:  Int J Dent       Date:  2017-08-07

8.  Microbiological Sealing Analysis of a Tapered Connection and External Hexagon System.

Authors:  Gardel Nepomuceno Costa; Elizabeth Ferreira Martinez; Aluísio Martins de Oliveira Ruellas; Daiane Cristina Peruzzo; Júlio Cesar Joly; Marcelo Henrique Napimoga
Journal:  Int J Dent       Date:  2017-02-28

9.  Effect of Surgical Installation of Dental Implants on Surface Topography and Its Influence on Osteoblast Proliferation.

Authors:  Helder H M Menezes; Marina M Naves; Henara L Costa; Tarsis P Barbosa; Jéssica A Ferreira; Denildo Magalhães; Elizabeth F Martinez
Journal:  Int J Dent       Date:  2018-10-17

10.  Comparative evaluation of peri-implant tissues in patients wearing mandibular overdenture with different implant platforms.

Authors:  Laércio Almeida de Melo; Danielle Bezerra de Farias; Annie Karoline Bezerra de Medeiros; Gustavo Augusto Seabra Barbosa; Euler Maciel Dantas; Adriana da Fonte Porto Carreiro
Journal:  J Indian Soc Periodontol       Date:  2017 Nov-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.