Literature DB >> 24741464

Intra-observer reproducibility of whole slide imaging for the primary diagnosis of breast needle biopsies.

Carolina Reyes1, Offiong F Ikpatt1, Mehrdad Nadji1, Richard J Cote1.   

Abstract

BACKGROUND: Automated whole slide imaging (WSI), also known as virtual microscopy is rapidly becoming an important tool in diagnostic pathology. Currently, the primary utilization of the technique is for transmission of digital images, for second opinion consultation, as well as for quality assurance and education. The high-resolution of digital images along with the refinement of technology could now allow for WSI to be used as an alternative to conventional microscopy (CM) as a first line diagnostic platform. However, the accuracy and reproducibility of the technology for the routine histopathologic diagnosis has not been established yet. This study was undertaken to compare the intra-observer variability of WSI and CM in the primary diagnosis of breast biopsies.
MATERIALS AND METHODS: One hundred and three consecutive core needle biopsies of breast were selected for this study. Each slide was digitally scanned and the images were stored in a shared file. Three board-certified pathologists independently reviewed the glass slides by CM first, and in an interval of 2-3 weeks for the 2(nd) time to establish their baseline CM versus CM reproducibility. They then reviewed the digital images of all cases following the same interval of time to compare the reproducibility of WSI versus CM for each observer. The diagnostic categories included the typical range of benign and malignant mammary lesions.
RESULTS: The intra-observer variability for CM versus CM was 4%, 7%, and 0% for observers 1, 2, and 3 respectively. The diagnostic variability for WSI versus CM was 1%, 4%, and 1% for the same observers. All diagnostic disagreements were between ductal hyperplasia and atypical ductal hyperplasia. There was no intra-observer disagreement in the diagnosis of benign versus malignant disease.
CONCLUSIONS: The intra-observer variability in the diagnosis of the core needle biopsies of the breast by high-resolution, WSI was the same as conventional glass slide microscopy. These results suggest that, WSI could be used similar to CM for the initial diagnosis of breast biopsies.

Entities:  

Keywords:  Breast biopsy; digital microscopy; reproducibility; whole slide imaging

Year:  2014        PMID: 24741464      PMCID: PMC3986536          DOI: 10.4103/2153-3539.127814

Source DB:  PubMed          Journal:  J Pathol Inform


INTRODUCTION

While digital pathology has been around for more than a decade, its widespread application for primary histologic diagnosis still awaits validation against the traditional glass slide microscopy. Slide digitalization mimics, the use of a microscope with capability of movement along the x and y planes as well as gradual increments in magnification.[123] Digital microscopy has been shown to have various practical applications including, quality assurance,[456] teleconsultation for second opinion,[78910] education,[1112] and intra-operative frozen section consultation.[10] It has also been shown that the use of whole slide digital images, improves workflow by eliminating the task of slide distribution and by facilitating filing and retrieving slides.[1] With the refinement of whole slide imaging (WSI) technology and high-resolution of digital images, the time is ripe to examine the accuracy of WSI as the first line diagnostic tool. There are no current guidelines, however, for the use of WSI as a primary diagnostic tool in pathology and hence, validation is needed before it could be incorporated in the clinical practice.[1131415] This requires comparison of intra-observer variability for WSI with that of microscopic evaluation of glass slides. In this study, the intrapathologist diagnostic reproducibility of WSI was compared to conventional microscopy (CM) in core needle biopsies of the breast. Determination of inter-observer variability was not the goal of this study.

MATERIALS AND METHODS

One hundred and three consecutive core needle biopsies of the breast from the files of Department of Pathology at the University of Miami, Jackson Memorial Medical Center were subjects of this study. The study coordinator selected one representative slide from each case for both CM and WSI. In some cases where there was more than one level on a single slide, all levels were scanned. The coordinator assigned random numbers to each case. Only H and E, slides were selected for microscopic review and digital imaging. In those cases where immunohistochemical (IHC) staining for diagnostic or predictive markers were performed, the IHC slides were excluded from the review process. Three board certified pathologists independently reviewed the H and E slides by CM and whole slide digital imaging. The three observers were all general surgical pathologists with experiences ranging from 5 years to 35 years. None of the pathologists had used WSI for primary diagnostic purposes before but had utilized the system for presentation at teaching conferences and tumor boards. Each pathologist initially, evaluated the glass slides of all cases by light microscopy (CM1) without the knowledge of the original pathologic diagnosis. In the next phase of the study, and following an interval period of 2-3 weeks, the glass slides with new random numbers were reviewed for the 2nd time by conventional light microscopy (CM2) to establish each pathologist's baseline reproducibility by CM. In the next step, the slides were assigned another set of random numbers and scanned at ×20 by BioImagene iScan Coreo Au (Ventana Medical System, Tucson, AZ). After a period of 2-3 weeks, each pathologist independently reviewed the digitalized images on his/her PC monitor accessed from the shared file. The diagnosis of the first and the second review by CM (CM1 and CM2) and by the WSI were tabulated for each observer by the study coordinator. The diagnostic disagreements between CM1 versus CM2, and CM1 versus WSI were calculated using the mean proportion differences. The assessment of inter-pathologist reproducibility was not the purpose of this study.

RESULTS

Among the 103 core needle biopsies, were 24 invasive ductal carcinomas, 22 in situ ductal carcinoma, 6 cases of atypical ductal hyperplasia, 11 cases of ductal hyperplasia without atypia, 5 intraductal papillomas, 4 fibroadenomas, 12 cases of sclerosing adenosis and 19 examples of fibrocystic changes not further characterized [Table 1].
Table 1

The original histologic diagnosis of 103 consecutive core needle biopsies of breast included in this study

The original histologic diagnosis of 103 consecutive core needle biopsies of breast included in this study The baseline intra-observer variability for the first CM versus the second CM was 4%, 7%, and 0% for pathologist 1, 2, and 3 respectively. When the CM1 diagnoses were compared to the WSI diagnoses, the variability for the observers was 1%, 4%, and 1% [Table 2]. All intra-pathologist disagreements were between the diagnoses of ductal hyperplasia versus atypical ductal hyperplasia. On the basis of H and E slide alone the observers had the same differential diagnostic difficulty with conventional microscope and WSI. No other diagnostic issues were observed that were specific to WSI. Interestingly, most of these cases were originally signed out with the aid of immunohistochemistry for p63 and high molecular weight cytokeratin. There were no significant differences between CM1 versus CM2 compared to WSI versus CM1 for individual observer or for the three pathologists as a group [Table 2].
Table 2

Intra-observer variability for glass slide and whole-slide images*

Intra-observer variability for glass slide and whole-slide images*

DISCUSSION

Although, WSI has been in use for more than a decade, its principal utility has been for telepathology consultation, education, and quality assurance. The application of the technique to primary diagnosis in surgical pathology has been rather slow. Among the reasons for the delayed implementation of WSI in diagnostic surgical pathology one could name technical and regulatory factors as well as hesitation by the pathology community to accept WSI as a viable alternative to conventional glass slide microscopy. Some of the initial technical shortcomings of the WSI such as long scan time and insufficient image resolution have been overcome to a considerable degree in the past few years. What remains is the validation of WSI for primary diagnostic purposes to satisfy the strict requirements by the regulatory bodies and eventually by practicing pathologists. Recent studies have showed that, WSI could be an acceptable alternative to CM.[141617181920] Gilbertson et al., showed that using whole slide images in complex cases was sufficient for pathologists to make reliable diagnostic decisions.[14] Two other recent studies have also shown the use of WSI for the diagnosis of prostate specimens. Rodriguez-Urrego, et al. demonstrated that interpretation of prostate needle biopsies by WSI simulates routine microscopy in the assessment of histologic grade, perineural invasion, and tumor volume.[20] Similarly, Chargari, et al., showed that virtual microscopy is comparable to regular microscopy as a primary diagnostic tool for prostate needle biopsies.[21] Interestingly, these authors also reported that, WSI improves the accuracy of Gleason's grading of prostate adenocarcinomas. More recently, Jukic, et al., estimated the intra-pathologist diagnostic discrepancy between glass slides and digital slides in 296 cases from various organ systems.[22] They did not detect any significant differences between the diagnoses that were based on digital images and those on glass slides. Similar studies by Al-Janabi, et al., have showed the feasibility of WSI utilization in the initial diagnosis of gastrointestinal biopsies.[23] The present study was focused exclusively on the assessment of the intra-observer reproducibility of WSI for the primary diagnosis of breast core biopsies. An initial routine light microscopic review by each of the three pathologists was followed by a second review to establish their respective baseline diagnostic reproducibility. This was followed in 2-3 weeks, by review of the digitalized whole slide images. The reproducibility of each observer was compared to his/her baseline variability established by CM. The result showed that there were no significant differences in the reproducibility rates between the two platforms for each pathologist and for the whole group. In other words, the observers’ performance was same by WSI and CM for the primary diagnosis of breast lesions on core needle biopsies. The diagnostic disagreements for both CM and WSI were between ductal hyperplasia and atypical ductal hyperplasia; a differential that was originally resolved by IHC for basal/myoepithelial cell markers. Although, the pathologists expressed desire to review IHC slides, the study design was for H and E slides only. In 2012, Al-Janabi, et al., studied the concordance between the light microscopic diagnoses and the whole slide images on 100 breast specimens that included biopsies, resections, and mammoplasty samples. The cases were originally diagnosed by a single breast pathologist who also reviewed the digital images after a washout period of 6 months. The diagnoses were concordant in 93% of cases and slightly discordant, with no clinical significance, in 6% of cases. In the single remaining case with potentially prognostic implications, however, no final consensus could be reached when the slides were reviewed by a panel of breast pathologists.[24] The possibility of recall bias always exits when pathologists re-review previously examined slides. For the same reason, washout periods ranging from a few weeks to several months have been suggested for the repeat review. Although, we cannot completely rule out the possibility of recall bias in this study we feel that if there was any, it should have been the same for CM1 versus CM2, as the reviews were within similar time spans of WSI versus CM1. Recently the College of American Pathologists (CAP) assembled a Digital Pathology Work Group, to explore the requirements to validate a WSI system before it is utilized in clinical practice and to reduce the potential risk of misdiagnosis when this technology is used. The CAP group developed a number of statements that were placed online for public comments. Most respondents agreed with the CAP statements for validation of WSI for clinical diagnostic purposes, including adequate storage capacity and interface with the laboratory information systems.[1] In addition to standardization of technical platforms, and establishment of intra-pathologist reproducibility for WSI, other factors that may potentially delay its routine use include the pathologists’ level of comfort and its acceptance as an alternative to CM. Our results and those published by others supports the notion that properly validated WSI platforms could be used for routine first line diagnosis.
  24 in total

1.  Virtual microscopy and the Internet as telepathology consultation tools. A study of gastrointestinal biopsy specimens.

Authors:  R P Singson; S Natarajan; J K Greenson; A M Marchevsky
Journal:  Am J Clin Pathol       Date:  1999-06       Impact factor: 2.493

2.  Automated complete slide digitization: a medium for simultaneous viewing by multiple pathologists.

Authors:  F J Leong; J O McGee
Journal:  J Pathol       Date:  2001-11       Impact factor: 7.996

3.  Virtual microscopy for learning and assessment in pathology.

Authors:  Rakesh K Kumar; Gary M Velan; Sami O Korell; Madan Kandara; Fred R Dee; Denis Wakefield
Journal:  J Pathol       Date:  2004-12       Impact factor: 7.996

4.  Use of whole slide imaging in surgical pathology quality assurance: design and pilot validation studies.

Authors:  Jonhan Ho; Anil V Parwani; Drazen M Jukic; Yukako Yagi; Leslie Anthony; John R Gilbertson
Journal:  Hum Pathol       Date:  2006-03       Impact factor: 3.466

5.  Interobserver and intraobserver reproducibility in digital and routine microscopic assessment of prostate needle biopsies.

Authors:  Paula A Rodriguez-Urrego; Angel M Cronin; Hikmat A Al-Ahmadie; Anuradha Gopalan; Satish K Tickoo; Victor E Reuter; Samson W Fine
Journal:  Hum Pathol       Date:  2010-10-20       Impact factor: 3.466

Review 6.  Digital slides: present status of a tool for consultation, teaching, and quality control in pathology.

Authors:  Rafael Rocha; José Vassallo; Fernando Soares; Keith Miller; Helenice Gobbi
Journal:  Pathol Res Pract       Date:  2009-06-07       Impact factor: 3.250

7.  Randomized comparison of virtual microscopy and traditional glass microscopy in diagnostic accuracy among dermatology and pathology residents.

Authors:  Laine H Koch; James N Lampros; Laura K Delong; Suephy C Chen; John T Woosley; Antoinette F Hood
Journal:  Hum Pathol       Date:  2009-01-14       Impact factor: 3.466

8.  Virtual microscopy in pathology education.

Authors:  Fred R Dee
Journal:  Hum Pathol       Date:  2009-06-21       Impact factor: 3.466

9.  Whole slide images as a platform for initial diagnostics in histopathology in a medium-sized routine laboratory.

Authors:  Shaimaa Al-Janabi; André Huisman; Marius Nap; Ruud Clarijs; Paul J van Diest
Journal:  J Clin Pathol       Date:  2012-10-23       Impact factor: 3.411

10.  Whole-slide imaging digital pathology as a platform for teleconsultation: a pilot study using paired subspecialist correlations.

Authors:  David C Wilbur; Kalil Madi; Robert B Colvin; Lyn M Duncan; William C Faquin; Judith A Ferry; Matthew P Frosch; Stuart L Houser; Richard L Kradin; Gregory Y Lauwers; David N Louis; Eugene J Mark; Mari Mino-Kenudson; Joseph Misdraji; Gunnlauger P Nielsen; Martha B Pitman; Andrew E Rosenberg; R Neal Smith; Aliyah R Sohani; James R Stone; Rosemary H Tambouret; Chin-Lee Wu; Robert H Young; Artur Zembowicz; Wolfgang Klietmann
Journal:  Arch Pathol Lab Med       Date:  2009-12       Impact factor: 5.534

View more
  13 in total

1.  Use of Digital Whole Slide Imaging in Dermatopathology.

Authors:  Tracy Onega; Lisa M Reisch; Paul D Frederick; Berta M Geller; Heidi D Nelson; Jason P Lott; Andrea C Radick; David E Elder; Raymond L Barnhill; Michael W Piepkorn; Joann G Elmore
Journal:  J Digit Imaging       Date:  2016-04       Impact factor: 4.056

2.  Diagnostic Reproducibility: What Happens When the Same Pathologist Interprets the Same Breast Biopsy Specimen at Two Points in Time?

Authors:  Sara L Jackson; Paul D Frederick; Margaret S Pepe; Heidi D Nelson; Donald L Weaver; Kimberly H Allison; Patricia A Carney; Berta M Geller; Anna N A Tosteson; Tracy Onega; Joann G Elmore
Journal:  Ann Surg Oncol       Date:  2016-12-02       Impact factor: 5.344

Review 3.  Integrating digital pathology into clinical practice.

Authors:  Matthew G Hanna; Orly Ardon; Victor E Reuter; Sahussapont Joseph Sirintrapun; Christine England; David S Klimstra; Meera R Hameed
Journal:  Mod Pathol       Date:  2021-10-01       Impact factor: 7.842

4.  Reproducibility and Feasibility of Strategies for Morphologic Assessment of Renal Biopsies Using the Nephrotic Syndrome Study Network Digital Pathology Scoring System.

Authors:  Jarcy Zee; Jeffrey B Hodgin; Laura H Mariani; Joseph P Gaut; Matthew B Palmer; Serena M Bagnasco; Avi Z Rosenberg; Stephen M Hewitt; Lawrence B Holzman; Brenda W Gillespie; Laura Barisoni
Journal:  Arch Pathol Lab Med       Date:  2018-02-19       Impact factor: 5.534

5.  American Telemedicine Association clinical guidelines for telepathology.

Authors:  Liron Pantanowitz; Kim Dickinson; Andrew J Evans; Lewis A Hassell; Walter H Henricks; Jochen K Lennerz; Amanda Lowe; Anil V Parwani; Michael Riben; Col Daniel Smith; J Mark Tuthill; Ronald S Weinstein; David C Wilbur; Elizabeth A Krupinski; Jordana Bernard
Journal:  J Pathol Inform       Date:  2014-10-21

6.  Image Montaging for Creating a Virtual Pathology Slide: An Innovative and Economical Tool to Obtain a Whole Slide Image.

Authors:  Spoorthi Ravi Banavar; Prashanthi Chippagiri; Rohit Pandurangappa; Saileela Annavajjula; Premalatha Bidadi Rajashekaraiah
Journal:  Anal Cell Pathol (Amst)       Date:  2016-09-22       Impact factor: 2.916

7.  Digital pathology imaging as a novel platform for standardization and globalization of quantitative nephropathology.

Authors:  Laura Barisoni; Charlotte Gimpel; Renate Kain; Arvydas Laurinavicius; Gloria Bueno; Caihong Zeng; Zhihong Liu; Franz Schaefer; Matthias Kretzler; Lawrence B Holzman; Stephen M Hewitt
Journal:  Clin Kidney J       Date:  2017-02-18

8.  A multisite validation of whole slide imaging for primary diagnosis using standardized data collection and analysis.

Authors:  Katy Wack; Laura Drogowski; Murray Treloar; Andrew Evans; Jonhan Ho; Anil Parwani; Michael C Montalto
Journal:  J Pathol Inform       Date:  2016-11-29

9.  Whole Slide Imaging Versus Microscopy for Primary Diagnosis in Surgical Pathology: A Multicenter Blinded Randomized Noninferiority Study of 1992 Cases (Pivotal Study).

Authors:  Sanjay Mukhopadhyay; Michael D Feldman; Esther Abels; Raheela Ashfaq; Senda Beltaifa; Nicolas G Cacciabeve; Helen P Cathro; Liang Cheng; Kumarasen Cooper; Glenn E Dickey; Ryan M Gill; Robert P Heaton; René Kerstens; Guy M Lindberg; Reenu K Malhotra; James W Mandell; Ellen D Manlucu; Anne M Mills; Stacey E Mills; Christopher A Moskaluk; Mischa Nelis; Deepa T Patil; Christopher G Przybycin; Jordan P Reynolds; Brian P Rubin; Mohammad H Saboorian; Mauricio Salicru; Mark A Samols; Charles D Sturgis; Kevin O Turner; Mark R Wick; Ji Y Yoon; Po Zhao; Clive R Taylor
Journal:  Am J Surg Pathol       Date:  2018-01       Impact factor: 6.394

10.  Exploring virtual reality technology and the Oculus Rift for the examination of digital pathology slides.

Authors:  Navid Farahani; Robert Post; Jon Duboy; Ishtiaque Ahmed; Brian J Kolowitz; Teppituk Krinchai; Sara E Monaco; Jeffrey L Fine; Douglas J Hartman; Liron Pantanowitz
Journal:  J Pathol Inform       Date:  2016-05-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.